Lar Produtos Projeto de Linha de Produção Linha de teste automático MCB

Linha de teste automático MCB

High‑speed MCB automatic testing line (1,800‑2,400 pcs/h) with multi‑station parallel testing, vision inspection, automatic sorting, and full data traceability. Solves testing bottlenecks, cuts field failures by 70%, and provides IEC/UL audit‑ready reports. Quick changeover (<30 min). MES ready.

IEC/UL · High‑speed sorting

Ultra‑High Speed MCB Automated Testing & Sorting Line

Customer pain points: Because manual testing is very slow in high-volume production, operators may miss defects due to lack of proper test data traceability/analysis. Changeover time to different MCB types can take hours, resulting in expensive downtime. The MCB automatic testing line addresses these issues with millisecond sorting, multi-station parallel testing, and full data traceability to allow manufacturers to achieve 100% IEC/UL compliance and reduce rework by more than 80%.

Use of high-speed indexing tables and robotic loading/unloading provides non-stop operation. At the same time, tests (trip time (B/C/D curves), thermal magnetic calibration, and contact resistance) can be done, critical tolerances can be verified using high-resolution vision, and an ultra-stable sorting mechanism will separate Pass, Fail, and Rework products. The data acquisition system (DAS) logs all tests variables to maintain complete traceability. The transition times between different pole (1P-4P) and current ratings are measured in minutes rather than hours. The average production of the machine(s) reaches 1,800-2,400 units/hour.

Standard delivery: 60-90 days | Quick changeover <30 min | MES‑ready DAS

MCB automatic testing line

High‑speed test & sorting line (actual product)

What Problems Does an MCB Automatic Testing Line Solve?

MCB manual testing creates 3 significant problems: inconsistent quality (human error causes trip time to vary), limited production volume (60-80 units tested/hour – 1000s tested/hour for automation), and no traceability (paper log cannot be audited). The MCB automated testing line removes all 3 of these barriers. The line automates the loading, testing, sorting and logging of data. For MCB manufacturers, this means: increased OEE; reduced cost of rework, and auditable data for IEC/UL certification. The automated testing lines also resolve the issues of switching between testing
methods (1P/2P/3P/4P) or changing current ratings with a changeover time of less than 30 minutes once programmed into HMI (according to recipe).

Eliminates testing bottlenecks

The use of multi-station parallel testing (instantaneous trip, thermal calibration and contact resistance) allows the testing of one unit to reduce testing times from 60 sec/manual to less than 3 sec/unit.

Provides full data traceability

All tests results (trip time, calibration value, pass/fail) will be stamped with time and serial no. Ensures ISO 9001; IEC audit compliance.

Enables rapid model changeover

Switching between different MCB types can take less than 30 minutes via recipe-based parameter switching, whereas manual recalibration can take hours.

Reduces field returns

Manually sampling does not catch all defects; however, by inspecting all items, many defects that would otherwise be missed will be captured. As a result, field failure rates may be reduced as much as 70%.

Technical Specifications – What the Line Delivers

High‑speed testing (1,800‑2,400 pcs/h), multi‑station parallel test (trip curve, calibration, contact resistance), vision inspection, automatic sorting, MES‑ready data logging.
Throughput (units/hour) 1,800 – 2,400 (depending on pole count)
Test coverage Instantaneous trip (B/C/D curves), thermal calibration (1.13×/1.45× In), contact resistance (µΩ), vision inspection (casing, label, screws)
Precisão atual ±0.5% of reading
precisão de tempo ±1ms for instantaneous; ±0.1% for thermal
Tempo de transição <30 minutes (recipe‑based, no tooling change for most parameters)
Saída de dados CSV, SQL, MES via OPC UA or Modbus TCP
Compatible MCBs 1P, 2P, 3P, 4P; 6A‑125A; B/C/D curves
Sistema de controle PLC (Siemens) + industrial PC, HMI touch screen
Fonte de energia 380V ±10% 50Hz | Compressed air 0.6MPa
Safety features Enclosed test area, emergency stop, light curtains, interlock doors

Core Customer Benefits – Why Manufacturers Choose This Line

Benefit 1: 25× higher throughput

Manual Testers are able to do 60-80 units per hour. Using this line a tester can handle 1,800-2400 units per hour. This results in a 25-30x increase in productivity to meet maximum demand without needing to add shifts or employ additional test personnel and typically achieve a return on investment (ROI) in less than nine months.

Benefit 2: Zero operator‑induced variation

Testers exhibit variability in their results due to factors such as time of day, fatigue, etc. In contrast, the automated process achieves much higher precision (±1 ms) than human testers as a result of utilizing high precision sensors on the test line (±0.5%), thus avoiding false passes and false failures.

Benefit 3: Complete audit‑ready traceability

The trip time, calibration values, contact resistance and visible results of every unit have been recorded with a date/time stamp and serial number. Export to a paperless report for IEC/UL audits, instead of searching through paper logs for your information.

Benefit 4: Fast changeover for mixed production

Change from single-phase, 10-amp, B type circuit breaker to three-phase, 63-amp, C type circuit breaker in under thirty (30) minutes. HMI loads new recipes; automatically adjusts test currents and time windows. No changes to mechanical components needed for most parameters.

Aprovado pelos líderes do setor

ABB
DELIXI
EKF
KRIPAL
HPL
CHAC
Schneider
IEK GROUP
SUNIR
Bevone
Weg
HUYU
RAAD
WALTONE
HAVELLS
C&S electric

Customer Success – How One Manufacturer Cut Field Returns by 72%

After implementing our automatic testing line for MCBs, a Chinese MCB producer that previously had a 1.2% field failure rate because of a missed calibration drift through traditional (10% sample) testing now has a corrected field failure rate of zero!!!

0.08% Field failure rate (down from 1.2%)
2,100 units/hour Test throughput (manual was 80)
100% Traceability for all production batches

The customer received value from the line within 11 months, evidenced by the customer passing a major distributor’s audit, with no non-conformities.

Applications – Where This Line Adds Most Value

High‑volume MCB production lines – Replace manual sampling with 100% inline testing.
Factories with frequent model changeovers – Recipe‑based switching reduces downtime.
Export‑oriented manufacturers – Full traceability required for IEC/UL certification.
Smart factory initiatives – MES integration for real‑time quality dashboards.

Engenharia e entrega personalizadas

1. Product & test spec review 15-30 days · MCB samples, test standards
2. Line layout & simulation 15-25 days · 3D layout, cycle time analysis
3. Manufacturing & assembly 60 a 90 dias
4. Pré-gordura Na fábrica de Benlong
5. Installation & commissioning On-site 10‑15 days
6. SAT final e treinamento 5‑7 days · acceptance report

Request a Custom MCB Testing Line Quote

Submit your MCB specifications, projections for throughput and test criteria. An engineering group will create a design that eliminates your testing bottleneck (with a complete return on investment analysis).

Consulte agora

WhatsApp: +86 150 5837 0007 | E-mail: xsb@benlongkj.cn | Suporte em inglês e chinês

Why Benlong for MCB Testing Automation?

  • Mais de 15 anos de experiência em design. high‑speed test and sorting lines for circuit breakers
  • Proven multi‑station parallel testing – 1,800‑2,400 units/hour
  • Full MES integration – OPC UA, Modbus TCP, SQL direct
  • Quick changeover recipe system – <30 minutes
  • Serviço global e suporte de peças de reposição

A linha padrão inclui

Features of systems include: High speed indexing table; robotic loading & unloading; multi-station test module (trip curve, calibration, contact resistance, vision); automatic sorting of products (pass, fail, rework); data acquisition System (DAS); PLC with HMI (Siemens); safety guarding; installation and training; 1-year warranty.

Perguntas frequentes

How does this line improve test reliability compared to manual sampling?

Only 5% – 10% of products are manually inspected, meaning up to 90% remain untested. With this system, 100% of products are tested with ±0.5% current accuracy and ±1ms timing, thus eliminating the risk of sending defective breakers. Field failure rates drop by 70% – 80% after installation.

Can the line be integrated with our existing assembly line?

Certainly! The assembly line is modular and an add on to your actual assembly line. You can send units to the new line from your conveyor and once they have been tested/sorted they will return to your packaging area. The modules include I/O and Ethernet communication to allow complete synchronisation across the assembly and testing lines.

What is the typical payback period?

When testing 500,000 MCBs each month, your expected payback is typically between 8 and 14 months based on a 2-3% decrease in defective parts and the ability to replace 4-6 testers with just one tester reducing labour costs, and avoiding the need to make warranty payments on inverter warranties.

Does the line support both thermal and magnetic trip testing?

The design incorporates a multi‑station configuration consisting of a thermal calibration (1.13×/1.45× In) and an instantaneous trip (5-10× In) module. The thermal and trip tests can both be run simultaneously on separate units, which allows for maximum throughput to be achieved.

How long does it take to train operators?

Training can be completed in two 8-hour days for operators. The HMI is easy to use; Select the recipe for the product you want to run, load the magazine, and press start. The Automated Flanging line does everything else including automatically sorting finished products and creating an electronic data log for each operator.

All specifications subject to final technical agreement. Benlong Automation – high‑speed MCB testing and sorting solutions for global manufacturers.

Produtos relacionados

MCB automatic assembly line

Linha de montagem automática MCB

Ver detalhes
Single phase meter automatic production line

Linha de produção automática de medidores monofásicos

Ver detalhes
Three phase electric meter automatic production line

Linha de produção automática de medidores elétricos trifásicos

Ver detalhes
Indicator light automatic production line

Linha de produção automática de luzes indicadoras

Ver detalhes
MCCB automatic production line

Linha de produção automática de MCCB

Ver detalhes
Air-operated Circuit Breaker (ACB) Automatic production line

Disjuntor pneumático (ACB) - Linha de produção automática

Ver detalhes

Enviar consulta

Demonstração do formulário de contato
WhatsApp
+86 150 5837 0007
Email
xsb@benlongkj.cn