خانه محصولات پروژه خط تولید خط تولید اتوماتیک قطع کننده مدار خلاء (VCB)

خط تولید اتوماتیک قطع کننده مدار خلاء (VCB)

Fully automatic VCB production line for 12KV/24KV vacuum circuit breakers. Servo‑aligned vacuum interrupter assembly, mechanism characteristic test (speed/travel/timing), HV insulation test, mechanical endurance cycling. IEC 62271‑100 compliant. 25‑30 units/shift, full traceability, remote diagnostics.

IEC 62271‑100 · 12/24KV

Automated VCB Assembly & Test Line for Medium‑Voltage Switchgear

The above-mentioned automatic assembly line for VCBs is a fully integrated assembly and testing facility for the medium and high voltages of 12KV and 24KV vacuum circuit breakers. The assembly line has a variety of motorised carriers, custom tooling, robotic handling, and functional test stations for verifying the high voltage capabilities of the finished products. These four integrated functions give various advantages and allow the precision and reliable manufacture of important products used to distribute power. Compliance with IEC 62271‑100 standards is achieved and the production capability on the line is from 25 to 30 units every 8 hour shift.

The primary processes include assembly of vacuum interrupter (system for relative positioning through servomechanical control) mechanical operation mechanism, testing of the mechanical operation mechanism (open/close speed, open/close travel, timing), testing insulation at high voltage (withstand voltage and loop resistances), mechanical testing for endurance operation for each product. Honeywell barcode scanning systems provide full traceability of material processed at each production point, while Benlong’s HMI/PLC software allows remote diagnostic capability. This is an ideal production line for manufacturers of switchgear products who need to meet Industry 4.0 standards, maintain quality consistency, and comply with IEC standards.

Standard delivery: 120-150 days | Customizable for 12KV/24KV | MES ready

Vacuum circuit breaker automatic production line

VCB assembly & test line (actual product)

What is a VCB Automatic Production Line?

An automatic production line for a Vacuum Circuit Breaker (VCB) is a specialized manufacturing system that produces vacuum circuit breakers (VCB) used in the medium voltage power distribution (12kV, 24kV, etc). The automatic production line automates the complete assembly process, from aligning and installing the vacuum interrupter (the central component for extinguishing electrical arcing) to assembling the spring-operated mechanism and completing electrical tests. The VCB assembly line consists of servo-controlled actuators that can accurately position the vacuum interrupter. There are automated test stations that measure mechanical characteristics of the VCBs (i.e., opening/closing speeds, travel, timing), perform high-voltage insulation tests (i.e., insulation withstand voltage, loop resistance), and perform mechanical endurance testing by completing thousands of operations to demonstrate and validate the long-term reliability of the VCB. Bar code readers are incorporated throughout the line to maintain full traceability, and the production line can be connected to a Manufacturing Execution System (MES) for data logging. The assembly line is a non-standard, custom solution that can be designed to fit your voltage rating (i.e., 12 kV, 24 kV, 40.5 kV), production volume and component design specifications.

Vacuum interrupter assembly

Custom jigs and servo-controlled actuators guarantee perfect micron-level alignment of the vacuum interrupter, which is important for breaking performance.

Mechanism characteristic testing

There is inspection of the speed at which the spring mechanism of an automated station opens/closes; distance travelled by the spring mechanism in opening/closing; and time taken for each.

High‑voltage insulation testing

Before leaving the line, all circuits must be tested for 100% in-line withstand voltage and loop resistance in accordance with IEC 62271-100.

Mechanical endurance cycling

Repetitive operation cycles are exceeded by the automated endurance test stations which carry out these cycles in an automated fashion.

Production Line Parameters (Standard Configuration)

Automated assembly and test line for 12KV/24KV VCBs. Daily output 25‑30 units, floor area ≈300 m², power <120 KW, IEC 62271‑100 compliant.
Applicable product specifications 12KV, 24KV
Daily output 25 – 30 pcs / 8H
Floor area (L×W×H) 38m × 7.7m × 3.0m (≈300 m²)
Input voltage 380V ± 10% (three‑phase five‑wire)
Voltage frequency 50Hz ± 1% & 60Hz ± 1%
Total power < 120 KW
Compressed air ≥ 1 m³/min, ≥ 6.5 kgf/cm² (oil‑free, water‑free)
Production line noise ≤ 75 dB (measured at 1m)
HMI / PLC software Benlong Automation (remote service supported)
International standard IEC 62271‑100

Key Component Brand Selection (Standard Configuration)

# Component Brand
1 HMI MCGS
2 Photoelectric Switches & Sensors Omron
3 Pneumatic Components Festo / Airtac / SMC
4 PLC Omron
5 Linear Guides HIWIN
6 Stepper Motors Sanyo
7 Electrical Components اشنایدر
8 Withstand Voltage Tester Chinese Brand
9 Loop Resistance Tester Chinese Brand
10 Drive Motors Chinese Brand
11 Bearings MISUMI
12 Barcode Reader Honeywell

مزایای فنی اصلی

Precision vacuum interrupter assembly

The vacuum interrupter’s alignment (with micron accuracy) is achieved using custom jigs and servo-controlled actuators which are essential for maintaining both vacuum integrity and contact gap. Proper alignment is vital to the breaker’s ability to interrupt short circuiting correctly.

Comprehensive mechanical characteristic verification

Automated mechanisms measure the time for opening/closing, speed of opening/closing, path (stroke) distance, and over travel distance. A record will be maintained for these measures and to show compliance with IEC 62271‑100 values so that the switch will operate reliably.

100% in‑line high‑voltage insulation testing

Prior to shipment off the production line, every VCB has to pass a withstand voltage (power frequency) test and a loop resistance test. These tests ensure that the VCB has both dielectric strength and low contact resistance, which are required for the continued reliability of a VCB in the power grid.

Full traceability & remote diagnostics

The Honeywell Barcode Reader can connect to different components, as well as test results, using a Unit Serial Number. The HMI/PLC software will allow you to connect remotely for both diagnostics and software updates to reduce both downtime and your transportation costs.

مورد اعتماد رهبران صنعت

ABB
DELIXI
EKF
KRIPAL
HPL
CHAC
Schneider
IEK GROUP
SUNIR
Bevone
Weg
HUYU
RAAD
WALTONE
HAVELLS
C&S electric

Customer Success Story – Medium‑Voltage Switchgear Manufacturer

To enhance production efficiency and quality when manufacturing 24kV VCBs compliant with IEC 62271-100, a European switchgear supplier established a procedure to achieve traceability, establish mechanical characteristics, and develop a fully automated VCB assembly line by Benlong that included room to room vacuum interrupters, mechanical testing, and high voltage insulating testing facilities, before remounting for mechanical durability checks. The results are shown below after 6 months.

28 units/shift Achieved (manual was 12)
99.8% First‑pass yield (mechanical & electrical)
100% Traceability of components and test data

In 18 months, the investment in this line pays back, and the customer received full IEC-compliant to obtain a significant utility contract.

کاربردها و ادغام

VCB manufacturing plants – High‑volume production of 12kV/24kV breakers
Switchgear OEMs – In‑house production for power distribution panels
Power equipment contractors – Custom lines for railway or mining applications
خطوط آزمایشی تحقیق و توسعه – Scaled‑down version for new VCB development

Custom Engineering & Delivery

1. Product & process design 30-60 days · VCB samples, voltage rating, target output
2. Line layout & simulation 20-30 days · 3D layout, cycle time analysis
3. Manufacturing & assembly 120-150 days
4. Pre‑FAT در کارخانه بنلونگ
5. Installation & commissioning On-site 15‑20 days
۶. آزمون نهایی SAT و آموزش 7‑10 days · acceptance report

Request a Custom VCB Production Line Quote

To receive your VCB specifications (voltage rating, frame size, expected product out), we will provide you with an engineer-designed automated production line (one that requires no human interaction) that includes: a vacuum interrupter assembly, mechanical and electrical testing, and MES traceability. Also, a full analysis of ROI will be included.

همین حالا استعلام کنید

واتس‌اپ: +86 150 5837 0007 | ایمیل: xsb@benlongkj.cn | پشتیبانی انگلیسی و چینی

Why Choose Benlong for VCB Automation?

  • ۱۵+ سال سابقه طراحی VCB assembly and test lines for medium‑voltage switchgear
  • Proven vacuum interrupter assembly with servo alignment
  • Integrated mechanical characteristic, HV insulation, and endurance testing
  • Full MES traceability with Honeywell barcode readers
  • خدمات جهانی و پشتیبانی قطعات یدکی

خط استاندارد شامل می‌شود

Motorized Conveyors, Vacuum Interrupter Jig Assemblies, Spring Mechanism Assembly Workstations, Mechanism Characteristic Testing (speed, stroke length and timing), High Voltage Withstand Voltage Testing, Loop Resistance Testing, Mechanical Endurance Cycle Testing Workstation, Honeywell Barcode Readers, PLC with HMI (Omron), Remote Diagnostic Software, SafetyGuarding, Installation and Training Services, and One Year Warranty.

سوالات متداول

What voltage ratings does the line support?

Our standard lines are built for 12 kV and 24 kV VCBs (modular, self-supporting with plastic housings), however we have custom-built (modular/supported) VCBs available for higher than that – up to 40.5 kV and any other preferred voltage rating by the customer.

How is the vacuum interrupter aligned during assembly?

Accurate positioning of the interrupter is achieved through servo-controlled actuators and custom made jigs with micron-level precision measurement. Prior to proceeding to the next assembly step, alignment is verified with sensors to ensure proper contact gap and integrity of vacuum seal.

What mechanical characteristics are measured?

Opening speeds, closing speeds, total actual travel, over travel, opening time, closing time, and contact bounce (if available) are measured by the automated test station. Then, test values can be compared to IEC 62271-100 tolerances.

Does the line support remote diagnostics?

The HMI/PLC application prepared by Benlong has an option for remote connections to allow the authorised service engineer to connect to the system via a secure VPN for troubleshooting and software updates.

What is the typical lead time for a custom line?

A lead time of 120-150 days is typical from the date of contract signing to factory acceptance for a standard 12kV/24kV line. Additional lead time for custom voltage ratings or additional automation could increase by 30-60 days.

All specifications subject to final technical agreement. Benlong Automation – IEC 62271‑100 compliant VCB production solutions since 2010.

محصولات مرتبط

Load isolation switch Automatic Testing line

سوئیچ ایزولاسیون بار خط تست خودکار

مشاهده جزئیات
Solid State Relay Automated Production Line

خط تولید خودکار رله حالت جامد

مشاهده جزئیات
Indicator light automatic production line

خط تولید اتوماتیک چراغ نشانگر

مشاهده جزئیات
MCB automatic testing line

خط تست اتوماتیک MCB

مشاهده جزئیات
IOT Smart MCB automatic production line

خط تولید اتوماتیک MCB هوشمند IOT

مشاهده جزئیات
Surge protection Device (SPD) Automatic Production line

دستگاه محافظت در برابر نوسانات برق (SPD) خط تولید اتوماتیک

مشاهده جزئیات

ارسال درخواست

نسخه آزمایشی فرم تماس
WhatsApp
+86 150 5837 0007
Email
xsb@benlongkj.cn