Bàn thử điện áp cao bán tự động MCCB
Semi‑automatic MCCB high voltage test bench covers 125A‑1250A (7 frame sizes) in one platform. Quick‑clamp system, OK/NG red/green indicator lights, touchscreen HMI, real‑time display. Reduces equipment investment by up to 70%, changeover time to under 5 minutes. IEC 60947‑2 compliant hi‑pot testing.
Semi‑Automatic MCCB High Voltage Withstand Test Bench
The MCCB semi-automatic testing bench for withstand voltage (dielectric strength) testing of MCCBs was designed with the capability to accommodate multiple frame sizes within one structure using a unique multiple frame design providing significant savings in equipment and time by using one platform with the ability to test seven different frame sizes of MCCBs; from 125/250A through 400/630/800/1000/1250A individually tested within one test setup. The 4 quick clamping systems and user friendly touch screen will allow the operator to perform each test cycle quickly. The results of all tests are displayed back to the operator using OK/NG (Pass/Fail) indications (Green for Pass/Red for Fail) eliminating guesswork and increasing throughput on high volume production lines. The Digital Display/HMI Panel provide real time display of test parameters and results to capture data accurately during every withstand voltage test cycle; ensuring every MCCB produced out of production has a reliable quality assurance.
Standard delivery: 30-45 days | Covers 125A‑1250A | Quick‑clamp system | OK/NG indicator
What Problems Does This Test Bench Solve?
There are three significant issues that arise when using traditional MCCB high voltage testing: there needs to be separate testers for each frame size (cost of equipment), there are significant waiting periods during switch-overs (loss of production), and there can be multiple interpretations of test results (operator-error). The semi-automated bench solves all three challenges: one bench will cover 125A through to 1250A (7 frame sizes), switch-over time is only minutes due to a quick-clamp system, and OK/NG (green/red) indicators provide immediate and unambiguous results. The bench performs dielectric strength (hi-pot) testing (IEC 60947-2) at high voltage – Phase-to-Phase and Phase-to-Ground, while measuring leakage current. This bench is perfect for use in MCCB manufacturing lines, QC laboratories, and for receiving incoming inspections.
Available in several different frame sizes, including 125A, 250A, 400A, 630A, 800A, 1000A and 1250A. This will save you as much as 70% of your overall investment on electrical equipment.
Changeover between frame sizes takes minutes, not hours – maximizes production uptime.
Green light for pass, red light for fail – eliminates operator interpretation errors.
Live test parameters and results – full traceability for quality audits.
Key Features & Customer Benefits
Thông số kỹ thuật
| Cycle time | Depends on MCCB model and frame size (typically 5‑10 seconds per test) |
|---|---|
| Machine dimensions (W×D×H) | 1,800 × 1,500 × 1,900 mm |
| Voltage | 380V, 50Hz |
| Compatible frame sizes | 125A, 250A, 400A, 630A, 800A, 1000A, 1250A |
| Test type | High voltage withstand (dielectric strength) test |
| Result output | OK / NG indicator (green / red light) |
| Automation type | Semi‑automatic (quick‑clamp + touchscreen operation) |
| OEM availability | Appearance and interface (customizable) |
| PLC | Omron (Japan) |
| Tester | Entai (China) |
Key Components (Standard Configuration)
| Component | Brand | Origin |
|---|---|---|
| PLC | Omron | Japan |
| Tester | Entai | China |
| Pneumatic cylinders | Festo & SMC | Germany & Japan |
Core Customer Benefits – Why Manufacturers Choose This Bench
Benefit 1: 70% lower capital investment
By using one bench to test all 125A-1250A MCCBs instead of having 7 testers (one for each frame size) we can achieve a maximum reduction of equipment costs by 70% and also free up a significant amount of factory floor space.
Benefit 2: 80% faster changeover
Changing frame sizes manually takes 15 to 30 minutes. By using the Quick-Change Clamp System, we can reduce this time to less than five minutes and, as a result, we will save hours of testing time every week.
Benefit 3: Zero interpretation errors
Operators will not need to check digital displays and determine if they passed or failed anymore, because OK (green) / NG (red) lights provide immediate, clear answers — eliminating variation between batches.
Benefit 4: Real‑time data for quality audits
HMI shows live test voltage and leakage current. All test parameters/results may be logged and exported, allowing full traceability for ISO 9001 and IEC audits.
Customer Success – How One Manufacturer Saved $150,000 in Test Equipment
After switching from using 6 dedicated hi-pot testers for differing frame sizes (125A – 1250A) to using this semi-automated high voltage tester (which covers all sizes), the MCCB manufacturer achieved:
The bench paid for itself in 6 months and freed up 15 m² of factory floor space.
Applications – Where This Bench Adds Most Value
Custom Engineering & Delivery
Request a Custom MCCB High Voltage Test Bench Quote
Provide your MCCB frame dimensions and voltage testing specifications, then our engineering dept will design a semi-auto hi-pot test bench that includes a fast clamp fixture plus an “OK/NG” light indicator, and of course a complete ROI analysis.
WhatsApp: +86 150 5837 0007 | Email: xsb@benlongkj.cn | Hỗ trợ tiếng Anh và tiếng Trung
Why Choose Benlong for Hi‑Pot Test Benches?
- Hơn 15 năm kinh nghiệm thiết kế MCCB test equipment for global manufacturers
- Proven multi‑frame design – one bench covers 125A‑1250A
- Quick‑clamp system for 80% faster changeover
- OK/NG indicator lights – zero operator interpretation errors
- Dịch vụ toàn cầu và hỗ trợ phụ tùng thay thế
Standard Bench Includes
High Voltage Testers(Entai) · Quick Clamp System With 7 Frame Adapters· Touch Screen HMI (MCGS)·OK/NG Indicator Lights w/Red & Green·Safety Enclosure w/Interlock·Omron PLC ·Operation Manual Included ·Calibration Certificate ·Warranty 1Yr.
Câu hỏi thường gặp
When the MCCB successfully passes the high voltage withstand test (leakage current is less than the set limit), the indicator will have a green light. If it fails (leakage > the set limit), then it will show a red light and indicate either excess leakage or a dielectric breakdown. As such, the result is instantaneous and eliminates any operator error in interpreting the results.
The standard bench comes with quick-change adapters for 7 frame sizes: 125 A, 250 A, 400 A, 630 A, 800 A 1000A, and 1250A. You can create custom adapters to fit additional frame sizes.
The fast-, clamp system enables a change of table type to be done in less than five minutes compared to the traditional 15 to 30 minutes.
Correct. Live test parameters such as voltage, leakage current and duration will be displayed on HMI (Human Machine Interface). Optional recording of these test values can be recorded on USB or MES (Manufacturers Embedded System) interface for complete traceability.
An interlock door encloses the testing area, meaning that high voltage cannot be operated while the interlock door is opened. There is also an emergency stop button provided.