Maison Produits Projet de banc d'essai Banc d'étalonnage thermique longue durée MCB

Banc d'étalonnage thermique longue durée MCB

MCB long time thermal calibration bench for overload testing per IEC 60898‑1. Multi‑station (4‑16), high‑stability current (0‑500A, THD<3%), timing accuracy ±0.1%, data logging. Ideal for MCB production QC, type testing, and R&D. Customizable for 6A‑125A.

IEC 60898‑1 · Long‑time overload test

Professional MCB Long‑Time Thermal Calibration Bench

Long-time thermal calibration for MCB in the Bus Mould case.

The Long Time Thermal Calibration Bench conforming with IEC 60898-1 provides a professional testing tool to performed to verify the thermal (long-delay) tripping characteristics of Minature Circuit Breakers (MCB) and assess their ability to trip correctly within a specified time range when tested with overload currents that are below the instantaneous levels (1.13×, 1.45× In).

The Long Time Thermal Calibration Bench provides the capability to simulate long time duration overload current conditions at precise control of test current, time and temperature influences, all resulting in stable and repeatable results. Therefore, it is ideal for use as part of a routine type testing process, within a production line sampling basis, or for laboratory verification purposes.

With the modular layout of the system, multiple MCB’s can be tested at the same time (multi-station). Each station has its own constant current supply (up to 500A per station, true RMS), a precision timer (precision +/- 0.1%) and independent pass / fail indication. There are built-in safety features (overload, overtemperature, short circuit) and data recording to ensure reliability. There are optional temperature monitoring and MES Data Export. Most common applications for use are MCB manufacturing QC, certification laboratories and R&D validation.

Standard delivery: 30-45 days | Multi‑station parallel test | Data logging & safety protection

MCB long time thermal calibration bench

Multi‑station thermal calibration bench (actual product)

What is an MCB Long‑Time Thermal Calibration Bench?

An MCB long term thermal calibration bench is the specialized test rig to verify the overload trip characteristics of miniature circuit breakers by applying a stable, overload current at a set value (normally 1.13 x In for no trip check and 1.45 x In for trip test), for a defined duration (seconds to hours) and measuring the exact trip time. Unlike instantaneous magnetic testers, the thermal calibration test bench utilises the bimetal thermal trip element, which has a trip phenomenon which is dependent upon the magnitude of the current, the ambient temperature and the duration of the test. The bench is equipped with a constant current source with a low waveform distortion (

Multi‑station parallel test
Test 4‑16 MCBs simultaneously for high throughput.
High‑stability current source
Up to 500A per station, accuracy ±1%, THD <3%.
Precise timing
Timing range 1s – 9h 59min, accuracy ±0.1%.
Data logging & safety
Automatic recording, overload/over‑temp protection.

Spécifications techniques

High‑precision multi‑station thermal calibration bench for MCB overload testing. Programmable current (0‑500A), timing accuracy ±0.1%, data recording, safety protection.
Alimentation électrique AC 220V ±10%, 50Hz
Air supply pressure 0.2 – 0.8 MPa (for pneumatic clamps, optional)–
Rated power per station 1 kVA (standard)–
Maximum output current per station Up to 500A (configurable, true RMS)–
Current display range 0.01 – 500A (true RMS value)–
Time display range 1 second – 9 hours 59 minutes 59 seconds–
Précision du chronométrage ±0.1% of reading–
Overall measurement accuracy ±1.0% (current)–
Distorsion de la forme d'onde (THD) < 3%–
résistance d'isolation > 10 MΩ–

Principaux avantages techniques

Multi‑station parallel testing

The modular design allows 4‑16 independent test stations, each with its own current source and timer. This drastically reduces per‑unit test time and increases throughput – essential for high‑volume MCB production lines.

Exceptional current stability & low distortion

The constant current source delivers stable output over long test durations (drift <2% over 8 hours) with total harmonic distortion below 3%. This ensures accurate bimetal heating and repeatable trip times per IEC standards.

Comprehensive safety & data management

Built‑in overload, over‑temperature, and short‑circuit protection automatically cut power in fault conditions. The data recording system logs trip time, test current, and pass/fail status for each station, enabling SPC analysis and quality traceability.

User‑friendly control & flexible test profiles

The HMI touch screen allows programming of test current, trip time windows, and pre‑test dwell times. Operators can run standard 100% / 135% In sequences or custom profiles for R&D. One‑key start for routine QC tests.

Reconnue par les leaders du secteur

ABB
DELIXI
EKF
KRIPAL
HPL
CHAC
Schneider
IEK GROUP
SUNIR
Bevone
Weg
HUYU
RAAD
WALTONE
HAVELLS
C&S electric

Customer Success Story – MCB Manufacturer

Due to inconsistent thermal trip calibration, a top manufacturer of MCBs had high levels of rework. The old calibration bench had a very unstable current (drifting over 5%) and contained only one testing position. When Benlong delivered an 8-station long-term thermal calibration bench with closed loop current control and data logging to them, this was their result after doing so for three months.

Throughput (single to 8 stations)
99.5% Rendement du premier passage (en hausse par rapport à 92%)
-70% Rework labor

The bench paid for itself in 9 months and passed IEC audit with full traceability records.

Applications et intégration

MCB manufacturing QC – Routine thermal calibration on production lines
Type test laboratories – Certification testing per IEC 60898‑1
Validation de la R&D – Characterizing new bimetal materials
Inspection à réception – Verifying purchased MCBs meet trip curves

Ingénierie et livraison sur mesure

1. Analyse des besoins 10-20 days · MCB ratings, test volume, number of stations
2. Current source & station design 15-30 days · 4‑16 stations, cooling system
3. Fabrication 30 à 45 jours
4. Pre‑FAT À l'usine de Benlong
5. Installation et formation On-site 3‑5 days
6. SAT final 3‑5 days · acceptance report

Request a Custom MCB Long‑Time Calibration Bench Quote

Our engineers will build a testing bench based on your MCB specifications (current ratings and test volume) using the best combination of testing locations per product, current range, and data logging – also including an ROI analysis.

Renseignez-vous dès maintenant

WhatsApp : +86 150 5837 0007 | Courriel : xsb@benlongkj.cn | Assistance en anglais et en chinois

Why Choose Benlong for MCB Calibration Benches?

  • Plus de 15 ans d'expérience en conception thermal calibration equipment for MCB manufacturers
  • Proven high‑stability current sources (drift <2% over 8 hours, THD <3%)
  • Multi‑station parallel testing (4‑16 stations)
  • ±0.1% timing accuracy, ±1% current accuracy
  • Full data logging & safety protection

Standard Bench Includes

Constant voltage source, 0 to 500 Amps per station; Multi-station Test Stand; HMI Touch Screen Control; Digital Timers with accuracy +/- 0.1%; Data Collection Software; Overload and (or) Over Temperature Protection; Calibration Certificate Included; 1 Year Warranty.

Foire aux questions

What test currents does the bench apply?

Generally at 100 percent, or 135 percent for trip time and no-trip verification per data bus protocol, of the rated current for the current transformer under test. Bench also accommodates custom test currents for R&D and custom test procedures as required.

How many MCBs can be tested at once?

The standard arrangement is: 4, 8, 12, or 16 independent stations, each with a current source and timer, allowing for parallel testing capabilities.

Is temperature compensation available?

Yes, it is possible to add an optional ambient temperature sensor to the system. Additionally, you have two options for testing: you could either have your temperature-dependent memory testing automatically update based on temperature measured from the optional ambient temperature sensor, or you could place your system inside of a climate chamber.

Can the bench be used for MCCB thermal testing?

The industry standard bench will accommodate MCB (miniature circuit breakers) for up an electrical current of 125 amps. For MCCB (molded case circuit breakers/greater capacity/bigger frame) breaker’s, we have developed an individual MCCB long‐time thermal calibration bench with the ability to support up to 1600 amps.

What is the typical test duration for a 100A MCB?

The test will run for 1 hour (no trip) at 100% In, and at 135% In, the trip times are usually between 45 – 55 sec. These sequences can be run automatically by the bench.

All specifications subject to final technical agreement. Benlong Automation – IEC 60898‑1 compliant MCB calibration solutions.

Produits associés

MCB semi-automatic thermal trip calibration bench Type-A

Banc d'étalonnage semi-automatique de déclenchement thermique MCB de type A

Voir les détails
MCCB Semi Automatic High voltage test bench

Banc d'essai semi-automatique haute tension pour disjoncteur MCCB

Voir les détails
MCB semi-automatic magnetic trip test bench

Banc d'essai semi-automatique de déclenchement magnétique pour disjoncteurs miniatures (MCB)

Voir les détails
Magnetic ring current test bench

Banc d'essai de courant annulaire magnétique

Voir les détails
RCBO Automatic Magnetic Reset + Testing machine

Réarmement magnétique automatique RCBO + machine de test

Voir les détails
MCCB Tripping mechanism test machine

Machine d'essai du mécanisme de déclenchement MCCB

Voir les détails

Envoyer une demande

Démonstration du formulaire de contact
WhatsApp
+86 150 5837 0007
Email
xsb@benlongkj.cn