Maison Produits Projet de banc d'essai Banc d'étalonnage manuel de déclenchement thermique MCB

Banc d'étalonnage manuel de déclenchement thermique MCB

Manual MCB thermal trip calibration bench for short‑time delay testing. Adjustable overload current (0‑125A), digital timer (±0.1%), stable current source. Portable, affordable, ideal for small‑batch production, lab, and field use. Customizable current range and clamps.

Short‑time delay · Manual operation

MCB Manual Short‑Time Delay Thermal Trip Calibration Bench

The MCCB Manual Thermal Trip Calibration Test Bench is an instrument developed to perform long delays on Miniature Circuit Breakers (‘MCB’) by evaluating and measuring their short‐term delay via a manual method. The MCB will demonstrate delay trip characteristics through user‐defined test parameters of overload current and time duration in a controlled overload environment or condition. Test parameters are displayed digitally, maintaining a clean test channel, with an interface providing accurate measurements relating to the time duration of short term delay. The fabrication of this MCB Manual Calibration Test Bench is durable and easy to operate; thus being ideal as an analysis and inspection laboratory for small production output. Therefore, certifying the MCB meets the standards of short-term delay testing per IEC 60898‐1 thus making it an independent, objective manner of confirming that MCB will operate safely and correctly under the designed conditions.

This bench allows you to adjust the current manually (or digitally) with either a variable resistor or encoder, gives you a display of real time trip time on the LCD display, and optionally also has an audible alarm to indicate if the test passed or failed. The bench is designed to be compact, easy to transport, and suitable to be used in the field as well as in research & development laboratories (R&D), and for low volume production lines where flexibility is more important than fully automated testing. Common uses for the bench would be performing a batch sampling or verifying prototypes, and maintaining the short time trip characteristics of MCBs.

Standard delivery: 30-45 days | Manual current setting | Digital timer ±0.1%

MCB manual thermal trip calibration bench

Manual short‑time delay test bench (actual product)

What is an MCB Manual Thermal Trip Calibration Bench?

The MCB Manual Thermal Trip Calibration Test Bench is a basic testing apparatus used to verify the short time delay (thermal overload) characteristic of miniature circuit breakers. The MCB manual thermal trip calibration test bench is fundamentally different from automatic test benches in that the MCB manual thermal trip calibration test bench requires the operator to manually set the test current (for example, using a dial or by entering it digitally), and to observe the trip time on a digital timer. It is designed to be used for low volume applications and therefore requires that the test bench be flexible, easy to use, and cost effective. The MCB manual thermal trip calibration test bench includes a stable constant current source, a digital timer with an accuracy of ±0.1%, and a simple fixture for connecting the MCB. The MCB manual thermal trip calibration test bench is commonly used in small laboratories, field maintenance, and as a backup for production lines. As a non-standard custom solution, we can customize the current range, fixture, and timer to meet your specific MCB ratings and testing requirements.

Manual current setting

Potentiometer or digital encoder for precise overload current selection.

Digital timer

Clear LED or LCD display, accuracy ±0.1%, range up to 99 hours.

Stable test channels

Constant current source with low drift (<2% over 8 hours).

Compact & portable

Lightweight design for field service or lab bench use.

Spécifications techniques

Manual short‑time delay calibration bench for MCBs. Programmable current (up to 125A), digital timer (±0.1%), stable current source, portable design.
Test current range 0 – 125A (customizable up to 200A)
Current setting Manual potentiometer or digital encoder (step 0.1A)
Timing range 0.1s – 9999s (or up to 99 hours)
Précision du chronométrage ±0.1% of reading
Afficher LED or LCD digital timer, current readout optional
Modes de test No‑trip check (100% In) and trip test (135% In or user‑set)
Fixture type Manual screw‑type clamps for 1P/2P/3P/4P MCBs
Alimentation électrique 220V ±10% 50Hz
Dimensions (L×W×H) Approx. 400mm × 350mm × 200mm (portable)
Weight Approx. 15kg

Principaux avantages techniques

Simple manual operation – no training required

Technicians can use this bench without having prior experience using automated equipment. Simply turn the dial to the current value and push the Start button; the time it takes to complete the task will be displayed as well as whether the trip timing met the pass/fail criteria on the timer (or an additional buzzer that could be added as an option).

Stable current for repeatable results

The constant current source has a high level of accuracy and will keep the set current at ±2% during long duration tests. The waveform has very little distortion (

Versatile fixture for multiple MCB types

Manual clamps allow for changes in MCB size (1P/2P/3P/4P) without requiring new tooling. Adjustable contacts allow you to accommodate different terminal spacing (17.5 mm – 25 mm).

Affordable & portable for field use

The bench weighs only 15 kilograms and can be transported to job sites easily. An optional carrying case and battery-operated timer are available for off-grid testing of the bench.

Reconnue par les leaders du secteur

ABB
DELIXI
EKF
KRIPAL
HPL
CHAC
Schneider
IEK GROUP
SUNIR
Bevone
Weg
HUYU
RAAD
WALTONE
HAVELLS
C&S electric

Customer Success Story – Electrical Contractor

A contractor wanted to test short-term delay trips on mini circuit (MCB) in the field after lightning strikes. The customer needed a portable battery-operated bench. Benlong supplied the customer with a manual thermal trip test bench for calibration and had an internally mounted rechargeable battery pack, both designed for use in a rugged way. The results of these benches after six (6) months were:

200+ Field tests performed
100% Defective breakers identified
12 months Battery life (rechargeable)

The bench paid for itself in 4 months by preventing nuisance trips and unnecessary replacements.

Applications et intégration

Small‑batch MCB manufacturing – Low‑volume calibration and sampling
Electrical field service – On‑site verification of trip characteristics
R&D laboratories – Prototype testing and curve characterization
Technical schools & training – Student hands‑on learning of overload protection

Ingénierie et livraison sur mesure

1. Analyse des besoins 5-10 days · current range, timer type, portable options
2. Design & fixture selection 10-20 days · custom current source, clamps
3. Fabrication 30 à 45 jours
4. Pre‑FAT À l'usine de Benlong
5. Installation et formation On-site 1‑2 days
6. SAT final 1‑2 days · acceptance report

Request a Custom Manual Calibration Bench Quote

Please provide your MCB rating, test current range, and any portability requirements. Our engineers will create a simple, reliable manual thermal trip bench for you along with a complete ROI.

I hope the above complies with your request! Best, [Your Name]

Renseignez-vous dès maintenant

WhatsApp : +86 150 5837 0007 | Courriel : xsb@benlongkj.cn | Assistance en anglais et en chinois

Why Choose Benlong for Manual Calibration Benches?

  • Plus de 15 ans d'expérience en conception MCB test equipment for professional and field use
  • Simple, rugged, and cost‑effective designs
  • Stable current source with long‑term reliability
  • Portable options for on‑site testing
  • Assistance mondiale en matière de service et de pièces détachées

Standard Bench Includes

(0-125A) steady state current supply, digitally timed to within plus or minus 0.1%, electrically adjustable via an adjustment knob, includes test lead with universal clamp type connectors, includes overload fuse, includes operators manual, calibrated at time of certification, includes one-year warranty.

Foire aux questions

What is the difference between short‑time delay and long‑time delay testing?

Thermal trip tests usually have short time delays and are required to provide overload currents at current levels of 1.45x In, measuring the current-tripping time from seconds to minutes. Long time delay tests (e.g. 1 Hour @ 100% In) would be done on the bench type for type tests. This bench was designed to perform short time delay verifying tests.

Can this bench test both 1P and 3P MCBs?

Sure. All of the universal clamps will work with 1 pole, 2 pole, 3 pole and 4 pole circuit breakers. If you are testing multi-pole circuit breakers, you will need to test each pole separately (in a sequence).

How is the test current set?

The front panel has an analog or digital meter that will show you the value of your actual current with a manual potentiometer dial or a digital encoder enabling you to increase or decrease the current by turning the knob until you have the required amount of current.

Does the bench include overload protection?

The current supply has short circuit protection using a breaker or fuse inside. There is also overheating shut off built in.

Can it be used for RCCB/RCBO testing?

The purpose of this bench is for MCB thermal (overload) testing only. There is a separate RCBO test bench with a demagnetisation function available for testing RCBOs for residual current.

All specifications subject to final technical agreement. Benlong Automation – manual MCB calibration solutions for laboratory and field.

Produits associés

MCCB manual thermal calibration bench

Banc d'étalonnage thermique manuel MCCB

Voir les détails
AC contactor comprehensive test machine

machine de test complète pour contacteurs CA

Voir les détails
Auxiliary and Signal Contact test bench

Banc d'essai pour contacts auxiliaires et de signalisation

Voir les détails
Electric meter manual calibration bench

Banc d'étalonnage manuel pour compteur électrique

Voir les détails
Magnetic ring current test bench

Banc d'essai de courant annulaire magnétique

Voir les détails
MCCB Semi Automatic High voltage test bench

Banc d'essai semi-automatique haute tension pour disjoncteur MCCB

Voir les détails

Envoyer une demande

Démonstration du formulaire de contact
WhatsApp
+86 150 5837 0007
Email
xsb@benlongkj.cn