產品 測試台項目 MCB手動磁脫扣試驗台

MCB手動磁脫扣試驗台

Manual MCB magnetic trip test bench for instantaneous short‑circuit protection testing. Adjustable test current (5‑10× In), digital timer (±1ms), universal fixture for 1P‑4P MCBs. Ideal for small‑batch production, lab, and field service. IEC 60898‑1 compliant.

Short‑circuit test · Manual control

Manual MCB Magnetic Trip Test Bench for Instantaneous Protection

The MCB magnetic trip test bench is a high precision system used to test the instantaneous magnetic trip protection of miniature circuit breakers (MCBs). This unique operational configuration enables the operator to manually determine the level of test current and observe the instantaneous trip characteristics of the MCB under simulated short-circuit conditions. The MCB test rack enables accurate measurement of trip current and response time to ensure that all MCBs conform to applicable safety standards (IEC 60898-1). The bench features a simple, rugged, and user-friendly design making it suitable for small production runs, laboratory testing, and quality inspection. The manual testing system offers users consistently reliable performance, ease of use, and repeatable results for verifying the operational characteristics of the MCB magnetic trip feature.

Standard delivery: 30-45 days | Manual current adjustment | Digital timer ±1ms

MCB manual magnetic trip test bench

Manual magnetic trip test station (actual product)

What is an MCB Manual Magnetic Trip Test Bench?

The MCB Manual Magnetic Trip Test Bench is a very simple but effective test method for checking the instant trip (magnetically) protection of MCBs by short circuit. Manually operated manual mode allows manual adjustment of the test current via either a potentiometer or encoder; after the test current setting has been made, the operator starts the test by injecting a high current pulse (typically between 5 and 10 times the rated current), and records the time it takes to trip the MCB in milliseconds on a digital timer. This type of system is well suited for low volume production, portable applications, and educational labs where price and flexibility are more important than higher levels of fully automated throughput; and conforms to the requirements of IEC 60898-1 for instant trip testing of the protective characteristics of MCBs. As a non-standard/custom configured solution, we will work with you to develop the appropriate current range (up to 5,000A peak) based on your specific product line. In addition to making the proper fixture and timer to suit the particular MCB series.

Manual current adjustment

Dial or digital encoder for precise test current setting (5‑10× In).

High‑precision timer

Digital display, range 0‑999ms, accuracy ±1ms.

Universal fixture

Adjustable clamps for 1P, 2P, 3P, 4P MCBs.

IEC 60898‑1 compliant

Supports B, C, D trip curve testing.

技術規格

Manual magnetic trip test bench for MCBs. Programmable test current (5‑10× In), digital timer (±1ms), universal fixture, manual current adjustment.
Test current range 5×, 7.5×, 10× In (manual adjustment, up to 5,000A peak)
Current setting method Manual potentiometer or digital encoder
Timing range 0 – 999ms
計時精度 ±1ms
展示 LED digital timer, current meter (optional)
Fixture Universal clamps for 1P/2P/3P/4P MCBs (adjustable spacing)
電源 220V ±10% 50Hz (control) + high‑current source input
Dimensions (L×W×H) Approx. 500mm × 400mm × 300mm (desktop)
Weight Approx. 20kg
Safety features Enclosed test chamber (optional), emergency stop

核心技術優勢

Simple, rugged design for daily use

Constructed using heavy-duty industrial-grade components and featuring a stout, solid construction to endure the rigors of high-volume recurring use in production floor and after-market field environments. There is no need for an extraordinary level of training; operators will be able to perform testing within minutes.

Accurate manual current setting

The adjustment of the test current multiplier (e.g., 5x, 7.5x, and 10x) can be made accurately with a large dial or digital encoder. The operator has total control and can see the actual current on either an analogue or digital meter.

Fast, repeatable trip time measurement

The timer starts automatically when the current pulse is applied and stops when the MCB has tripped. The operator can read the result directly without needing to use a stopwatch.

Versatile fixture for different MCB types

The adjustable clamps can accept 1P, 2P, 3P, and 4P MCBs without the need for changing any tools. The space between each clamp is adjustable from 10mm – 30mm to match the terminal pitch of your terminals.

深受業界領導者信賴

ABB
DELIXI
EKF
KRIPAL
HPL
CHAC
Schneider
IEK GROUP
SUNIR
Bevone
Weg
HUYU
RAAD
WALTONE
HAVELLS
C&S electric

Customer Success Story – Electrical Workshop

After having no equipment to test MCBs (miniature circuit breakers) for their drop in performance due to new magnetics being added to them and needing to replace them, a small electrical workshop (within a control panel) now has a manual MCB Trip Bench that was created by Benlong. It is portable because it comes with a rugged carrying case and uses simple dial controls to measure magnetics. Results after 6 months of use:

200+ MCBs tested
100% Defective breakers identified
0% Unnecessary replacements

The bench paid for itself in 3 months by avoiding false replacements and reducing downtime.

應用與集成

Small‑batch MCB manufacturing – QC sampling and final inspection
Electrical field service – On‑site verification of existing MCBs
Technical training labs – Student experiments on short‑circuit protection
Maintenance workshops – Testing breakers after fault events

客製化工程與交付

1. 需求分析 5-10 days · current rating, test volume
2. Current source & fixture design 10-20 days · custom clamps, current range
3. Manufacturing & assembly 30-45天
4. Pre‑FAT 在 Benlong 工廠
5. 安裝與培訓 On-site 1‑2 days
6. 最終SAT 1‑2 days · acceptance report

Request a Custom Manual Magnetic Trip Bench Quote

Please provide your rating of MCB devices and the number of tests conducted daily on these devices. Our engineering department can then provide you with a basic manual magnetic trip testing solution that delivers desired performance by providing a reasonable margin of coverage (ROI).

立即諮詢

WhatsApp:+86 150 5837 0007 | 信箱:xsb@benlongkj.cn | 提供中英文支持

Why Choose Benlong for Manual Test Benches?

  • 15年以上設計經驗 MCB test equipment for professionals
  • Simple, robust, and cost‑effective designs
  • Accurate current generation (±5%) and timing (±1ms)
  • Universal fixture for 1P‑4P MCBs
  • 全球服務和備件支持

Standard Bench Includes

Manual adjustable high-current generator; Digital timer (±1ms ); Universal MCB clamps; Analog or digital current measuring device; Emergency stop switch; PPE; Operating manual; Calibration certificate; 1 Year warranty;

常見問題解答

What is the difference between magnetic trip and thermal trip?

An instantaneous magnetic trip is a mechanism to protect against short circuits. The breaker will trip nearly instantaneously when the current flowing exceeds approximately 5-10 times its rated capacity. A thermal trip is used to protect against overload conditions. The breaker will trip after several seconds to several minutes of continuous overload at approximately 1.13-1.45 times rated capacity. This bench test will only provide data for the magnetic trip portion of the breaker operation.

Can I test both B‑curve and C‑curve MCBs with this bench?

Sure. This bench lets you manually adjust the test current over its range. For B-curves, you will set the current to 5x In and for C-curves you will set it to 10x In (or in between). The timer will display the time it took to trip.

Does the bench require special power wiring?

A dedicated power feed (typically either 32 A to 63 A depending upon the maximum tested current) is required to supply the high current generator because a standard 220 V outlet is not suitable. The requirement will be defined by our engineers prior to the quote process.

Is the bench safe to operate?

Yes, there will be an emergency stop button as standard practice. A supplementary enclosed test chamber (with an interlock) may be added for further protection against accidental contact with the live terminal when conducting tests.

What is the typical test time per MCB?

The duration of manual testing for each MCB is about 10 to 20 seconds (this includes loading, setting of current, applying pulses to the MCB and unloading). In comparison, the actual duration of the high-current pulse is in hundreds of milliseconds.

All specifications subject to final technical agreement. Benlong Automation – manual MCB magnetic trip test solutions since 2008.

相關產品

MCCB long time thermal calibration bench

MCCB 長時間熱校準台

看詳情
Magnetic ring current test bench

磁環電流測試台

看詳情
MCB automatic magnetic trip test + on-off & high voltage test machine

MCB自動磁脫扣試驗機+開關及高壓試驗機

看詳情
MCB Electrical Endurance Test Bench

MCB電機耐久性測試台

看詳情
MCB long time thermal calibration bench

MCB長時間熱校準台

看詳情
RCBO Automatic Magnetic Reset + Testing machine

RCBO自動磁復位+測試機

看詳情

發送詢價

聯絡表單演示
WhatsApp
+86 150 5837 0007
Email
xsb@benlongkj.cn