{"id":531,"date":"2026-06-06T23:48:09","date_gmt":"2026-06-06T23:48:09","guid":{"rendered":"https:\/\/khkrh7q1ur.wpdns.site\/?p=531"},"modified":"2026-06-06T23:48:11","modified_gmt":"2026-06-06T23:48:11","slug":"mcb-calibration-machine-and-how-it-works","status":"publish","type":"post","link":"https:\/\/benlongkj.com\/tr\/blog\/mcb-calibration-machine-and-how-it-works\/","title":{"rendered":"MCB Kalibrasyon Makinesi Nedir ve Nas\u0131l \u00c7al\u0131\u015f\u0131r?"},"content":{"rendered":"<blockquote><p><strong>Ger\u00e7ek bir \u00fcretim ba\u015f a\u011fr\u0131s\u0131:<\/strong> Son test a\u015famas\u0131nda, termal a\u00e7ma sapmas\u0131 nedeniyle MCB'lerimizin 'ini reddediyorduk. MCB devresindeki sorunun nedeni, kulland\u0131\u011f\u0131m\u0131z kalibrasyon tezgah\u0131n\u0131n 30 dakikadan uzun s\u00fcreler boyunca sabit ak\u0131m sa\u011flayamamas\u0131yd\u0131. \u00d6nceki kalibrasyonlar\u0131m\u0131zla bimetallerin do\u011fru ayarland\u0131\u011f\u0131n\u0131 do\u011frulaman\u0131n bir yolu yoktu. \u2014 Kalite M\u00fcd\u00fcr\u00fc, orta \u00f6l\u00e7ekli elektrikli cihaz \u00fcreticisi<\/p><\/blockquote>\n<p><a title=\"MCB kalibrasyon makineleri\" href=\"https:\/\/benlongkj.com\/tr\/mcb-semi-automatic-thermal-trip-calibration-bench-type-b-product\/\"><strong>MCB kalibrasyon makineleri<\/strong><\/a> minyat\u00fcr devre kesicilerin termal veya a\u015f\u0131r\u0131 y\u00fck a\u00e7ma \u00f6zelliklerini test etmek ve ayarlamak i\u00e7in kullan\u0131lan \u00f6zel cihazlard\u0131r. Kalibrasyon tezgahlar\u0131, devre kesicilerin a\u00e7\u0131lma s\u00fcresini \u00f6l\u00e7erken hassas ve sabit a\u015f\u0131r\u0131 y\u00fckler (genellikle 100% ile 135% aras\u0131nda) uygulayabilir (+\/- 0,1%) \u00f6l\u00e7erken, devre kesicilerin \u00e7ok dar bir aral\u0131kta (\u00f6rne\u011fin, 135% In'de 45 \u2013 55 saniye) a\u00e7\u0131lmas\u0131n\u0131 sa\u011flayacak \u015fekilde bimetal \u015ferit ayar\u0131n\u0131n yap\u0131lmas\u0131na yard\u0131mc\u0131 olur. Bu k\u0131lavuz, bir MCB kalibrasyon makinesinin nas\u0131l do\u011fru \u015fekilde kullan\u0131laca\u011f\u0131n\u0131 a\u00e7\u0131klamaktad\u0131r; makine t\u00fcrlerini (manuel, yar\u0131 otomatik, uzun s\u00fcreli) listelemekte ve \u00fcretim laboratuvar\u0131n\u0131z veya \u00fcretim tesisiniz i\u00e7in do\u011fru makineyi nas\u0131l se\u00e7ece\u011finiz konusunda bilgi vermektedir.<\/p>\n<h2>Bu k\u0131lavuz \u015funlar\u0131 kapsar:<\/h2>\n<ul>\n<li>MCB kalibrasyon cihaz\u0131 nedir ve bir test cihaz\u0131ndan ne fark\u0131 vard\u0131r?<\/li>\n<li>\u00c7al\u0131\u015fma prensibi: termal devre kesme sim\u00fclasyonu, ak\u0131m kontrol\u00fc ve zamanlama<\/li>\n<li>Kalibrasyon tezgah\u0131 t\u00fcrleri: manuel, yar\u0131 otomatik (A\/B tipi) ve uzun s\u00fcreli tezgahlar<\/li>\n<li>De\u011ferlendirilmesi gereken temel teknik \u00f6zellikler (ak\u0131m aral\u0131\u011f\u0131, do\u011fruluk, kararl\u0131l\u0131k)<\/li>\n<li>Hacim ve hassasiyet gereksinimlerine g\u00f6re kalibrasyon cihaz\u0131 nas\u0131l se\u00e7ilir<\/li>\n<li>S\u0131k\u00e7a Sorulan Sorular: MCB kalibrasyonu, do\u011fru \u00e7al\u0131\u015fma testi ve 80% kural\u0131<\/li>\n<\/ul>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-532\" src=\"https:\/\/benlongkj.com\/wp-content\/uploads\/2026\/06\/What-is-a-MCB-Calibration-Machine-and-How-Does-it-Work.webp\" alt=\"MCB Kalibrasyon Makinesi Nedir ve Nas\u0131l \u00c7al\u0131\u015f\u0131r\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>1. MCB kalibrasyon makinesi nedir? (Tan\u0131m ve ama\u00e7)<\/h2>\n<p>MCB'ler i\u00e7in bir kalibrasyon cihaz\u0131 (Termal A\u00e7ma Kalibrasyon Tezgahlar\u0131 olarak da bilinir), minyat\u00fcr devre kesicilerin termal a\u015f\u0131r\u0131 y\u00fck eleman\u0131n\u0131 kalibre etmek \u00fczere tasarlanm\u0131\u015ft\u0131r. Her MCB'nin i\u00e7inde, i\u00e7inden ge\u00e7en a\u015f\u0131r\u0131 y\u00fck ak\u0131m\u0131n\u0131n \u0131s\u0131nmas\u0131 nedeniyle b\u00fck\u00fclen bir bimetalik \u015ferit bulunmaktad\u0131r. \u015eerit \u00e7ok erken veya \u00e7ok ge\u00e7 b\u00fck\u00fcl\u00fcrse, yay\u0131nlanan zaman-ak\u0131m karakteristi\u011finin (IEC 60898-1'e g\u00f6re) d\u0131\u015f\u0131nda devreye girer. Kalibrasyon makinesi, kalibre edilen MCB'ye sabit bir ak\u0131m (Tip B\/C\/D i\u00e7in 1,45\u00d7 nominal ak\u0131m) uygular ve devreye girmesi i\u00e7in ge\u00e7en ger\u00e7ek s\u00fcreyi \u00f6l\u00e7er. A\u00e7ma s\u00fcresi elde edildikten sonra, kabul aral\u0131\u011f\u0131 d\u0131\u015f\u0131ndaysa, operat\u00f6r (veya otomatik ayar istasyonu) bir kalibrasyon vidas\u0131n\u0131 \u00e7evirerek bimetalik \u015feridin sapmas\u0131n\u0131 art\u0131rarak veya azaltarak ayarlar. Ayarlamadan sonra, a\u00e7ma i\u015flemi do\u011fru spesifikasyon aral\u0131\u011f\u0131na girene kadar yeniden test edilir. Bu s\u00fcre\u00e7, her MCB'nin \u00fcreticiden \u00e7\u0131kt\u0131\u011f\u0131nda ayn\u0131 koruma seviyesini sa\u011flayaca\u011f\u0131n\u0131 garanti eder.<\/p>\n<p>Benlong Automation'\u0131n \u00fcr\u00fcn \u00f6rnekleri aras\u0131nda \u015funlar yer almaktad\u0131r: (yeni ba\u015flayanlar i\u00e7in) en uygun MCB Manuel Termal A\u00e7ma Kalibrasyon Tezgah\u0131 (giri\u015f seviyesi) ve MCB'lerin farkl\u0131 tasar\u0131m \u00f6zelliklerine uygun, vites mekanizmal\u0131 A Tipi Yar\u0131 Otomatik Tezgah.<\/p>\n<h2>2. MCB kalibrasyon makinesi nas\u0131l \u00e7al\u0131\u015f\u0131r?<\/h2>\n<p>\u00c7al\u0131\u015fma prensipleri temel olarak 3 ana alt sistemden olu\u015fur: ak\u0131m \u00fcretimi, zamanlama \u00f6l\u00e7\u00fcm\u00fc ve sabitleme deste\u011fi.<\/p>\n<h3>2.1 Kararl\u0131, programlanabilir ak\u0131m kayna\u011f\u0131<\/h3>\n<p>Cihaz, modele ba\u011fl\u0131 olarak birka\u00e7 amper ile 500 amper aras\u0131nda ayarlanabilir bir alternatif ak\u0131m \u00fcretir. Kalibrasyon i\u00e7in, ak\u0131m\u0131n kalibre edilecek MCB\u2019nin (Minyat\u00fcr Devre Kesici) nominal ak\u0131m de\u011ferinin 51\u2019i olarak ayarlanmas\u0131 gerekir. 10 Amper nominal de\u011fere sahip tipik bir MCB i\u00e7in termal kalibrasyon ak\u0131m\u0131, termal (uzun vadeli) a\u00e7ma i\u015flevi i\u00e7in 13,5 Amper olarak ayarlanmal\u0131d\u0131r. Ak\u0131m ayr\u0131ca bir saatlik bir s\u00fcre boyunca \u00b12% tolerans aral\u0131\u011f\u0131nda tutulmal\u0131d\u0131r; aksi takdirde, devre kesme s\u00fcresi kayacak ve yanl\u0131\u015f sonu\u00e7lar ortaya \u00e7\u0131kacakt\u0131r. CW (Sabit Dalga) kararl\u0131l\u0131\u011f\u0131n\u0131n sabit Kapal\u0131 D\u00f6ng\u00fc Geri Beslemesini korumak i\u00e7in bir IGBT (Yal\u0131t\u0131ml\u0131 Kap\u0131l\u0131 Bipolar Transist\u00f6r) veya Trist\u00f6r denetleyicisi kullanan Benlong MCB uzun s\u00fcreli termal kalibrasyon tezgah\u0131, gerekli Kalibrasyon Ak\u0131m\u0131 kararl\u0131l\u0131\u011f\u0131n\u0131 sa\u011flayacakt\u0131r. Teknik performans \u00f6zellikleri \u015funlar\u0131 i\u00e7erir: \u0130stasyon Ba\u015f\u0131na Anma G\u00fcc\u00fc = 1 kVA, Maksimum \u00c7\u0131k\u0131\u015f = 500 Amper, Maksimum \u00c7\u0131k\u0131\u015f Dalga Formu Bozulmas\u0131 = &lt; 3%.<\/p>\n<h3>2.2 Y\u00fcksek hassasiyetli zamanlama ve devre kesme alg\u0131lama<\/h3>\n<p>Test cihaz\u0131n\u0131n bir par\u00e7as\u0131 olan dahili zamanlay\u0131c\u0131, test edilen MCB\u2019ye ak\u0131m akmaya ba\u015flad\u0131\u011f\u0131nda geri say\u0131ma ba\u015flar ve MCB\u2019nin t\u00fcm kontaklar\u0131 a\u00e7\u0131lana kadar devam eder. Zamanlama, uzun s\u00fcreli testler (1 ila 60 dakika) ba\u011flam\u0131nda \u00f6nemlidir \u00b10,1%; b\u00f6ylece, \u00f6rne\u011fin, 60 saniyelik bir a\u00e7ma i\u00e7in izin verilen hata 0,06 saniyeden fazla olmayacakt\u0131r. MCB uzun s\u00fcreli termal kalibrasyon tezgah\u0131n\u0131n veri sayfas\u0131, 1 saniye ile 9 saat 59 dakika aras\u0131nda zaman g\u00f6r\u00fcnt\u00fcleme aral\u0131klar\u0131 ile \u00b10,1% zamanlama do\u011frulu\u011fu belirtir. Verimi art\u0131rmak i\u00e7in, birden fazla istasyon (genellikle 4 ila 10) ayn\u0131 anda birden fazla MCB'yi test eder.<\/p>\n<h3>2.3 Sabitleme ve ayar mekanizmas\u0131<\/h3>\n<p>MCB\u2019leri kalibre etmek i\u00e7in kullan\u0131ld\u0131\u011f\u0131nda, Manuel Test Tezgahlar\u0131 \u2013 \u00f6rne\u011fin, termal a\u00e7ma kalibrasyon tezgah\u0131 kullanan MCB\u2019lerle birlikte kullan\u0131lmak \u00fczere tasarlanm\u0131\u015f olanlar gibi \u2013 mil \u00fczerine monte edilmi\u015f operat\u00f6r, MCB'nin manuel a\u00e7ma mekanizmas\u0131n\u0131 y\u00fckler ve dijital \u00f6l\u00e7\u00fcm ekran\u0131n\u0131 kullanarak MCB'nin termal a\u00e7\u0131lma s\u00fcresini kaydeder; bu noktada operat\u00f6r, ikinci bir test yapmadan \u00f6nce bir tornavida kullanarak MCB'nin kalibrasyon ayar\u0131n\u0131 yapar. Yar\u0131 Otomatik Tezgah Tip A ve B'nin cihaz \u00f6zellikleri aras\u0131nda pn\u00f6matik kelep\u00e7eler ve motorlu kalibrasyon ayarlay\u0131c\u0131 bulunur; operat\u00f6r sadece y\u00fckleme ve bo\u015faltma i\u015flemlerini ger\u00e7ekle\u015ftirir, makine testi yapar ve \u00e7oklu tekrarl\u0131 testler kullanarak a\u00e7ma s\u00fcresini kabul edilebilir bir aral\u0131\u011fa ayarlar ve operat\u00f6r\u00fcn ek m\u00fcdahalesine gerek kalmadan sonu\u00e7lar\u0131 operat\u00f6re sunar. Tip B Tezgah, birden fazla \u00fcretici grubunun MCB'leri dahil olmak \u00fczere \u00e7oklu test yetenekleri i\u00e7in de\u011fi\u015ftirilebilir kartlarla donat\u0131lm\u0131\u015ft\u0131r.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-533\" src=\"https:\/\/benlongkj.com\/wp-content\/uploads\/2026\/06\/Types-of-MCB-calibration-machines.webp\" alt=\"MCB kalibrasyon makinelerinin t\u00fcrleri\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>3. MCB kalibrasyon makinelerinin t\u00fcrleri<\/h2>\n<p>Otomasyon d\u00fczeyine ve test s\u00fcresine g\u00f6re, yayg\u0131n olarak \u00fc\u00e7 t\u00fcr vard\u0131r:<\/p>\n<ul>\n<li><strong>Manuel termal a\u00e7ma kalibrasyon tezgah\u0131: <\/strong>En uygun maliyetli se\u00e7enek $5.000 ile $15.000 aras\u0131ndad\u0131r. Operat\u00f6r, \u00fcretim s\u0131ras\u0131nda vidalar\u0131 manuel olarak de\u011fi\u015ftirmek i\u00e7in ge\u00e7i\u015f s\u00fcresini okuyacakt\u0131r. Bu se\u00e7enek ara\u015ft\u0131rma ve geli\u015ftirme \u00e7al\u0131\u015fmalar\u0131, k\u00fc\u00e7\u00fck partiler (200 adede kadar) ve saha kullan\u0131m\u0131 i\u00e7in uygundur.<\/li>\n<li><strong>Yar\u0131 otomatik kalibrasyon tezgah\u0131 (Tip A \/ Tip B): <\/strong>Tipik fiyat aral\u0131\u011f\u0131 $15k-35k aras\u0131ndad\u0131r; genellikle otomatik ak\u0131m uygulamas\u0131 (gerekli elektrik miktar\u0131 i\u00e7in) ve devre kesme alg\u0131lama (devre kesme meydana geldi\u011finde) ile bazen de motorlu ayar (y\u00fckleme\/bo\u015faltmaya uyum sa\u011flamak i\u00e7in) i\u00e7erir; operat\u00f6r y\u00fckleme\/bo\u015faltma; en \u00e7ok orta hacimli (200 \u2013 1500 \u00fcr\u00fcn\/g\u00fcn) uygulamalarda kullan\u0131l\u0131r; tip \u2018A\u2019, farkl\u0131 tipteki (MCB) tasar\u0131mlara uyum sa\u011flamak i\u00e7in bir kayd\u0131rma mekanizmas\u0131 i\u00e7erir; tip \u2018B\u2019, h\u0131zl\u0131 ge\u00e7i\u015f i\u00e7in tak\u0131labilir kartlar kullan\u0131r.<\/li>\n<li><strong>Uzun s\u00fcreli termal kalibrasyon tezgah\u0131: <\/strong>100% nominal ak\u0131m\u0131nda uzun s\u00fcreli \u00e7al\u0131\u015fma i\u00e7in tasarlanm\u0131\u015ft\u0131r (1 ila 8 saat). Tip testi (nominal elektriksel \u00f6zelliklerin do\u011frulanmas\u0131) veya termal haf\u0131za etkisinin do\u011frulanmas\u0131 amac\u0131yla kullan\u0131l\u0131r. Birden fazla ba\u011f\u0131ms\u0131z test istasyonu (4 ila 12) i\u00e7erebilir ve veri kayd\u0131 \u00f6zelli\u011fi sunabilir.<\/li>\n<\/ul>\n<h2>4. De\u011ferlendirilmesi gereken temel \u00f6zellikler (ger\u00e7ek verilerle)<\/h2>\n<p>MCB kalibrasyon cihazlar\u0131n\u0131 kar\u015f\u0131la\u015ft\u0131r\u0131rken, \u015fu belgelenmi\u015f de\u011ferleri isteyin:<\/p>\n<ul>\n<li><span style=\"color: #0000ff;\">\u00c7\u0131k\u0131\u015f ak\u0131m\u0131 aral\u0131\u011f\u0131 ve do\u011frulu\u011fu<\/span>: Benlong uzun vadeli test tezgah\u0131, istasyon ba\u015f\u0131na 0,01 ila 500 Amper aral\u0131\u011f\u0131nda \u00f6l\u00e7\u00fcm yapma imkan\u0131 sunar; \u00f6l\u00e7\u00fcm belirsizli\u011fi 1%'dir. Dikkate al\u0131nabilecek MCB de\u011ferleri 1 \u2013 63 Amper aras\u0131nda veya baz\u0131 durumlarda 125 Amper'e kadar de\u011fi\u015febilir.<\/li>\n<li><span style=\"color: #0000ff;\">Zamanlama do\u011frulu\u011fu<\/span>: \u00b10,11 TP3T veya daha iyi. Uzun s\u00fcreli testlerde, 8 saatlik sapma &lt;0,51 TP3T olmal\u0131d\u0131r.<\/li>\n<li><span style=\"color: #0000ff;\">Test istasyonu say\u0131s\u0131<\/span>: 1 ila 12. \u0130stasyon say\u0131s\u0131 artt\u0131k\u00e7a i\u015f hacmi artar, ancak daha fazla yer kaplar.<\/li>\n<li><span style=\"color: #0000ff;\">Dalga formu bozulmas\u0131<\/span>: &lt;3% (THD) \u2013 daha y\u00fcksek bozulma, bimetal \u0131s\u0131tmay\u0131 etkiler.<\/li>\n<li><span style=\"color: #0000ff;\">\u0130zolasyon direnci<\/span>: &gt;10 M\u03a9 (g\u00fcvenlik).<\/li>\n<li><span style=\"color: #0000ff;\">Standartlara uygunluk<\/span>: IEC 60898\u20111 (MCB'ler i\u00e7in) veya m\u00fc\u015fteriye \u00f6zel test planlar\u0131.<\/li>\n<\/ul>\n<h2>5. Fabrikan\u0131z i\u00e7in do\u011fru MCB kalibrasyon makinesini nas\u0131l se\u00e7ersiniz?<\/h2>\n<p>G\u00fcnl\u00fck \u00fcretim hacminize ve do\u011fruluk gereksinimlerinize g\u00f6re bu karar k\u0131lavuzunu kullan\u0131n:<\/p>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<thead style=\"background: #f0f0f0;\">\n<tr>\n<th style=\"border: 1px solid #ddd; padding: 8px;\">G\u00fcnl\u00fck \u00fcretim hacmi<\/th>\n<th style=\"border: 1px solid #ddd; padding: 8px;\">\u00d6nerilen makine<\/th>\n<th style=\"border: 1px solid #ddd; padding: 8px;\">En \u00f6nemli avantaj<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">&lt; 200 adet<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Manuel termal a\u00e7ma test tezgah\u0131<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">En d\u00fc\u015f\u00fck yat\u0131r\u0131m<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">200\u20131000 adet<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Yar\u0131 otomatik Tip A veya Tip B<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">H\u0131z ve maliyet dengesi<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">&gt;1000 adet<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">\u00c7ok istasyonlu uzun s\u00fcreli \u00e7al\u0131\u015fma tezgah\u0131<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Y\u00fcksek verim, veri kayd\u0131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u0130htiya\u00e7lar\u0131n\u0131z\u0131 de\u011ferlendirirken, yaln\u0131zca termal a\u00e7ma mekanizmalar\u0131n\u0131 m\u0131 yoksa yaln\u0131zca manyetik a\u00e7ma mekanizmalar\u0131n\u0131 m\u0131 test etmeniz gerekece\u011fini d\u00fc\u015f\u00fcnmelisiniz. Kalibrasyon tezgahlar\u0131n\u0131n \u00e7o\u011fu, yaln\u0131zca termal (uzun s\u00fcreli) a\u00e7ma mekanizmalar\u0131n\u0131n test edilmesi i\u00e7in tasarlanm\u0131\u015ft\u0131r. Manyetik a\u00e7ma testleri i\u00e7in ek bir anl\u0131k test cihaz\u0131na ihtiyac\u0131n\u0131z olacakt\u0131r, ancak her iki \u00f6zelli\u011fi de sunan baz\u0131 geli\u015fmi\u015f modeller de mevcuttur. Bu makalede daha \u00f6nce bahsetti\u011fimiz kalibrasyon tezgahlar\u0131, yukar\u0131daki iki a\u00e7ma t\u00fcr\u00fcnden herhangi birinin \u00f6zel kalibrasyonu i\u00e7in m\u00fckemmeldir.<\/p>\n<h2>S\u0131k\u00e7a sorulan sorular (SSS)<\/h2>\n<h3>MCB kalibrasyonu nedir?<\/h3>\n<p><strong>MCB kalibrasyonu<\/strong> Bir minyat\u00fcr devre kesicinin kalibrasyonu, termal a\u00e7ma mekanizmas\u0131nda (bimetal \u015ferit) ayarlamalar yap\u0131lmas\u0131n\u0131 gerektirir. Bu ayarlaman\u0131n amac\u0131, devre kesiciden a\u015f\u0131r\u0131 ak\u0131m ge\u00e7ti\u011finde kesicinin belirli bir s\u00fcre i\u00e7inde a\u00e7\u0131lmas\u0131n\u0131 sa\u011flamakt\u0131r. A\u015f\u0131r\u0131 y\u00fck ak\u0131m\u0131, IEC60898-1 standartlar\u0131nda Tip B, C ve D i\u00e7in belirtildi\u011fi \u00fczere nominal ak\u0131m\u0131n 1,45 kat\u0131 olarak ayarlanacakt\u0131r (yani, In'in 1,45 kat\u0131 olacakt\u0131r). Tipik olarak, devre kesicinin kalibrasyonunu ger\u00e7ekle\u015ftirmek i\u00e7in \u00f6zel bir kalibrasyon makinesi kullan\u0131l\u0131r. Kalibrasyon makinesi, kesiciye hassas ve sabit bir ak\u0131m uygulayacak, a\u00e7\u0131lma s\u00fcresini \u00f6l\u00e7ecek ve operat\u00f6r\u00fcn veya otomatik bir sistemin, a\u00e7\u0131lma standartlarda belirtilen s\u0131n\u0131rlar i\u00e7inde ger\u00e7ekle\u015fene kadar (\u00f6rne\u011fin, 10A'l\u0131k bir kesicinin @135% In'de 45 saniye ile 55 saniye aras\u0131nda olmal\u0131d\u0131r). Bu i\u015flemin ba\u015far\u0131yla tamamlanmas\u0131, devre kesicinin uzun s\u00fcreli a\u015f\u0131r\u0131 y\u00fcklerden g\u00fcvenilir koruma sa\u011flamas\u0131na olanak tan\u0131r.<\/p>\n<h3>Bir MCB'nin d\u00fczg\u00fcn \u00e7al\u0131\u015f\u0131p \u00e7al\u0131\u015fmad\u0131\u011f\u0131n\u0131 nas\u0131l kontrol edebilirim?<\/h3>\n<p>Bir minyat\u00fcr devre kesicinin d\u00fczg\u00fcn \u00e7al\u0131\u015f\u0131p \u00e7al\u0131\u015fmad\u0131\u011f\u0131n\u0131 belirlemek i\u00e7in, bir termal (a\u015f\u0131r\u0131 y\u00fck) testi ve bir manyetik (k\u0131sa devre) testi yapman\u0131z gerekir. Termal test i\u00e7in, nominal ak\u0131m\u0131n 1,45 kat\u0131n\u0131 uygulamak \u00fczere bir kalibrasyon cihaz\u0131 veya birincil ak\u0131m enjeksiyon seti kullan\u0131n ve a\u00e7\u0131lma s\u00fcresini kaydedin. MCB, 1 saat i\u00e7inde (10 A i\u00e7in) veya 1 dakika i\u00e7inde (daha d\u00fc\u015f\u00fck de\u011ferler i\u00e7in) a\u00e7\u0131lmal\u0131d\u0131r. Manyetik test i\u00e7in, nominal ak\u0131m\u0131n 5-10 kat\u0131n\u0131 (B, C, D e\u011frisine ba\u011fl\u0131 olarak) uygulay\u0131n; MCB, 100 milisaniye i\u00e7inde a\u00e7\u0131lmal\u0131d\u0131r. MCB'nin ANSI standartlar\u0131na uygun oldu\u011fundan emin olmak i\u00e7in kontak direncini (100 M\u03a9, 500V'da) kontrol edin. Bas-a\u00e7 d\u00fc\u011fmesi kullan\u0131larak yap\u0131lan basit bir saha testi, yaln\u0131zca mekanik ba\u011flant\u0131y\u0131 g\u00f6sterir, ancak elektriksel kalibrasyonu do\u011frulamaz.<\/p>\n<h3>Kesiciler i\u00e7in 80% kural\u0131 nedir?<\/h3>\n<p>NEC 210.20'ye g\u00f6re, 80% kural\u0131, bir devre kesicinin nominal de\u011ferinin (ak\u0131m de\u011feri) 80%'nin \u00fczerinde s\u00fcrekli olarak y\u00fcklenmesini yasaklamaktad\u0131r. \u00d6rnek olarak, bir MCB'nin ak\u0131m ta\u015f\u0131ma kapasitesi 20 A ise, bu, termal birikim nedeniyle 3 saatten fazla s\u00fcreyle yaln\u0131zca 16 A'l\u0131k bir ak\u0131m ta\u015f\u0131yabilece\u011fi anlam\u0131na gelir. Varsay\u0131m, termal birikimin neden oldu\u011fu hatal\u0131 devre kesintilerinin, s\u00fcrekli olarak a\u015f\u0131r\u0131 y\u00fcklenmi\u015f devrelerde meydana gelece\u011fidir. Kalibrasyonun 80% kural\u0131yla do\u011frudan bir ili\u015fkisi yoktur, ancak kalibrasyon prosed\u00fcr\u00fc, kesici 80% kural\u0131n\u0131 ihlal ederek devrede 100%'de s\u00fcrekli olarak y\u00fcklenmi\u015f olsa bile, a\u015f\u0131r\u0131 y\u00fcklendi\u011finde (nominal de\u011ferin 135%'si) kesicinin do\u011fru \u015fekilde devreye girece\u011fini garanti eder. Zamanla, bimetalin genle\u015fmesi nedeniyle kesiciden hatal\u0131 bir a\u00e7ma meydana gelme olas\u0131l\u0131\u011f\u0131 vard\u0131r; bu nedenle, kalibrasyonun a\u00e7man\u0131n standart zaman aral\u0131\u011f\u0131 i\u00e7inde ger\u00e7ekle\u015fti\u011fini do\u011frulamas\u0131 \u00e7ok \u00f6nemlidir. Baz\u0131 \u00fcreticiler, \u00f6zel uygulamalar i\u00e7in di\u011fer \u00fcreticilerle ayn\u0131 ak\u0131m ta\u015f\u0131ma kapasitesine sahip kesiciler \u00fcreterek bu standarda bir istisna olu\u015ftururlar.<\/p>\n<h3>MCB nedir ve i\u015flevi nedir?<\/h3>\n<p>MCB\u2019nin temel amac\u0131, 125 A\u2019ya kadar ak\u0131m de\u011ferine sahip al\u00e7ak gerilim elektrik devrelerini, a\u015f\u0131r\u0131 y\u00fck (uzun s\u00fcreli y\u00fcksek ak\u0131m) veya k\u0131sa devre (a\u015f\u0131r\u0131 y\u00fcksek ak\u0131m) kaynakl\u0131 hasarlara kar\u015f\u0131 koruyarak g\u00fcvence alt\u0131na almakt\u0131r. Bir MCB, a\u015f\u0131r\u0131 y\u00fck durumunu alg\u0131layan bir termal \u00fcniteye (bimetalik) ve k\u0131sa devre durumunu alg\u0131layan bir elektromanyetik \u00fcniteye sahiptir; k\u0131sa devre, esasen a\u015f\u0131r\u0131 ak\u0131m nedeniyle devre i\u00e7inde meydana gelen bir ar\u0131zad\u0131r. MCB'nin ba\u011fl\u0131 oldu\u011fu devrede herhangi bir ar\u0131za oldu\u011funda, MCB otomatik olarak devreye girer ve ar\u0131zal\u0131 devreye g\u00fc\u00e7 beslemesini keser; bu da yang\u0131nlara kar\u015f\u0131 koruma sa\u011flar ve ar\u0131zal\u0131 devreye ba\u011fl\u0131 ekipman\u0131n hasar g\u00f6rmesini \u00f6nler. MCB ayr\u0131ca, att\u0131\u011f\u0131nda de\u011fi\u015ftirilmesi gereken sigortalar\u0131n aksine, ar\u0131za giderildikten sonra s\u0131f\u0131rlanabilir. MCB'nin testi veya kalibrasyonu, termal \u00fcnitenin uygun ak\u0131m seviyesinde ve ayr\u0131ca IEC 60898-1'de belirtilen tan\u0131mlanm\u0131\u015f zaman aral\u0131\u011f\u0131 i\u00e7inde devreye girece\u011fini garanti etmek amac\u0131yla ger\u00e7ekle\u015ftirilir.<\/p>\n<p>MCB Kalibrasyon Makineleri, MCB\u2019lerin (minyat\u00fcr devre kesiciler) termal a\u015f\u0131r\u0131 y\u00fck korumas\u0131n\u0131 do\u011frulamak ve gerekli ayarlamalar\u0131 yapmak amac\u0131yla \u00fcreticiler, test ve kalibrasyon laboratuvarlar\u0131 ile bak\u0131m departmanlar\u0131 taraf\u0131ndan kullan\u0131lmaktad\u0131r. MCB Kalibrasyon Makineleri, MCB\/minyat\u00fcr devre kesiciye sabit ve hassas bir ak\u0131m (genellikle MCB nominal ak\u0131m\u0131n\u0131n 135%'si) uygulayarak ve devre kesicinin a\u00e7\u0131lmas\u0131n\u0131n ne kadar s\u00fcrd\u00fc\u011f\u00fcn\u00fc \u00f6l\u00e7erek (\u00e7ok y\u00fcksek hassasiyetle, \u00b10,1%) \u00e7al\u0131\u015f\u0131r.<\/p>\n<p>MCB kalibrasyon makineleri \u00e7e\u015fitli modellerde mevcuttur; manuel makineler, i\u015f hacminin az oldu\u011fu durumlarda (\u00f6rne\u011fin: ara\u015ft\u0131rma ve geli\u015ftirme) kullan\u0131l\u0131r; yar\u0131 otomatik makineler (A ve B Tipi), orta hacimli i\u015fleri ger\u00e7ekle\u015ftirerek verimlili\u011fi art\u0131rmak \u00fczere tasarlanm\u0131\u015ft\u0131r; otomatik olarak \u00e7al\u0131\u015fan uzun s\u00fcreli makineler ise b\u00fcy\u00fck hacimli i\u015fleri \u00fcstlenir.<\/p>\n<p>\u0130htiya\u00e7lar\u0131n\u0131za en uygun MCB kalibrasyon makinelerinin hangileri oldu\u011funu de\u011ferlendirirken, a\u015fa\u011f\u0131daki teknik \u00f6zellikleri g\u00f6z \u00f6n\u00fcnde bulundurun. Dikkate al\u0131nmas\u0131 gereken \u00e7ok \u00f6nemli teknik \u00f6zellikler \u015funlard\u0131r: Maksimum Ak\u0131m Aral\u0131\u011f\u0131 (maks. 500A), a\u00e7ma i\u015fleminde \u00e7ok y\u00fcksek hassasiyetli zaman \u00f6l\u00e7\u00fcm\u00fc, G\u00fcnde \u00e7al\u0131\u015ft\u0131rmak istedi\u011finiz MCB\/kalibrasyon say\u0131s\u0131 ve IEC 60898-1 standard\u0131na uygunluk.<\/p>\n<p>Se\u00e7im yaparken <strong>MCB Kalibrasyon Makineleri<\/strong>, g\u00fcnl\u00fck \u00fcretim hacminizi, b\u00fct\u00e7enizi ve ihtiya\u00e7 duydu\u011funuz otomasyon d\u00fczeyini g\u00f6z \u00f6n\u00fcnde bulundurun. MCB'lerin do\u011fru \u015fekilde kalibre edilmesi, a\u015f\u0131r\u0131 y\u00fck ko\u015fullar\u0131nda devreye girmelerini sa\u011flamaya yard\u0131mc\u0131 olacakt\u0131r. Do\u011fru kalibrasyon, hem ekipman\u0131 hem de personeli koruyacakt\u0131r.<\/p>","protected":false},"excerpt":{"rendered":"<p>Real production headache: During the final testing phase, we were rejecting 8% of our MCBs due to thermal trip drift. The reason for the issue with the MCB&#8217;s circuit was that the calibration bench that we were using did not hold stable current for time periods greater than 30 minutes. There was no way to [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":532,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-531","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/posts\/531","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/comments?post=531"}],"version-history":[{"count":1,"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/posts\/531\/revisions"}],"predecessor-version":[{"id":534,"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/posts\/531\/revisions\/534"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/media\/532"}],"wp:attachment":[{"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/media?parent=531"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/categories?post=531"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/tags?post=531"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}