{"id":482,"date":"2026-06-06T18:22:04","date_gmt":"2026-06-06T18:22:04","guid":{"rendered":"https:\/\/khkrh7q1ur.wpdns.site\/?p=482"},"modified":"2026-06-06T18:22:05","modified_gmt":"2026-06-06T18:22:05","slug":"2025-guide-effectively-test-vcb-breaker-testing-machines","status":"publish","type":"post","link":"https:\/\/benlongkj.com\/tr\/blog\/2025-guide-effectively-test-vcb-breaker-testing-machines\/","title":{"rendered":"2025 K\u0131lavuzu: VCB Kesici Test Cihazlar\u0131 Nas\u0131l Etkili Bir \u015eekilde Test Edilir?"},"content":{"rendered":"<blockquote><p><strong>Saha ar\u0131za maliyeti:<\/strong> 24 kV'luk bir VCB'de tespit edilemeyen bir vakum ka\u00e7a\u011f\u0131, k\u0131sa devrenin kesilememesine yol a\u00e7t\u0131. Bu trafo merkezi kesintisi, elektrik da\u011f\u0131t\u0131m \u015firketimize 1.420.000'den fazla zarara mal oldu ve bunu test prosed\u00fcrlerimiz nedeniyle g\u00f6zden ka\u00e7\u0131rd\u0131k. \u2013 Bak\u0131m m\u00fchendisi, b\u00f6lgesel elektrik da\u011f\u0131t\u0131m \u015firketi.<\/p><\/blockquote>\n<p>Bir VCB kesicinin test edilmesi, bir al\u00e7ak gerilim kesicisi veya MCB'nin test edilmesiyle ayn\u0131 \u015fey de\u011fildir. VCB'ler y\u00fcksek\/orta gerilim seviyelerinde (genellikle 12 kV ile 24 kV aras\u0131nda) \u00e7al\u0131\u015f\u0131r ve do\u011fru \u015fekilde \u00e7al\u0131\u015fabilmeleri i\u00e7in vakum kesicinin \u00f6zelliklerinden yararlan\u0131r. 2025 y\u0131l\u0131nda, elektrik \u015febekelerinin otomasyonunun uygulanmas\u0131yla birlikte, VCB'lerin d\u00fczg\u00fcn \u00e7al\u0131\u015fmas\u0131n\u0131 sa\u011flamak i\u00e7in, IEC 62271-100 standard\u0131na uygun olarak VCB'nin vakum b\u00fct\u00fcnl\u00fc\u011f\u00fcn\u00fc, mekanik i\u015flevselli\u011fini, yal\u0131t\u0131m direncini ve kontak a\u015f\u0131nmas\u0131n\u0131 do\u011fru bir \u015fekilde do\u011frulayabilen \u00f6zel ekipmanlara sahip olmak gereklidir. Bu makale, test etmek i\u00e7in ger\u00e7ekle\u015ftirmeniz gereken be\u015f temel do\u011frulamay\u0131 \u00f6zetlemektedir. <a title=\"VCB kesici testi\" href=\"https:\/\/benlongkj.com\/tr\/vcb-automaticproduction-line-product\/\"><strong>VCB kesici testi<\/strong><\/a> ekipman.<\/p>\n<h2>Bu k\u0131lavuz \u015funlar\u0131 kapsar:<\/h2>\n<ul>\n<li>VCB kesici test cihazlar\u0131 i\u00e7in be\u015f temel test (ve bunlar\u0131n nas\u0131l yap\u0131laca\u011f\u0131)<\/li>\n<li>Ba\u015far\u0131l\u0131 bir \u00f6l\u00e7\u00fcm i\u00e7in a\u015fa\u011f\u0131daki parametreler hayati \u00f6nem ta\u015f\u0131r: vakum seviyesi; temas mesafesi; a\u00e7\u0131lma\/kapanma h\u0131z\u0131; ve yal\u0131t\u0131m direnci.<\/li>\n<li>IEC 62271-100 standartlar\u0131na g\u00f6re sonu\u00e7lar\u0131n nas\u0131l yorumlanaca\u011f\u0131<\/li>\n<li>S\u0131k yap\u0131lan hatalar ve bunlardan ka\u00e7\u0131nman\u0131n yollar\u0131<\/li>\n<li>M\u00fchendisler taraf\u0131ndan yan\u0131tlanan VCB testleriyle ilgili s\u0131k sorulan sorular<\/li>\n<\/ul>\n<h2>VCB'nin ne oldu\u011funu ve testlerin neden \u00f6nemli oldu\u011funu anlay\u0131n<\/h2>\n<p>Test y\u00f6ntemlerine ge\u00e7meden \u00f6nce, VCB'nin \"Vakum Kesici\"nin k\u0131saltmas\u0131 oldu\u011funu hat\u0131rlamak \u00f6nemlidir. Bir vakum kesici, ar\u0131za durumunda kontaklar a\u00e7\u0131ld\u0131\u011f\u0131nda ark\u0131 s\u00f6nd\u00fcrecek vakum tipi bir cihaza sahiptir. Ya\u011f veya hava kesicilerin aksine, Vakum Kesicide g\u00f6zle g\u00f6r\u00fcl\u00fcr bir ark olu\u015fmaz ve minimum bak\u0131m gerektirir. Ancak, son derece az miktarda vakum bile Vakum Kesicinin ar\u0131zay\u0131 kesmesini engelleyece\u011finden, Vakum Kesiciyi test etmek \u00f6nemlidir. Otomatik \u00fcretim hatt\u0131nda Vakum Kesicileri test etmek i\u00e7in yerle\u015fik otomatik test istasyonlar\u0131 bulunur; bu istasyonlar, \u00fcretim s\u0131ras\u0131nda bu \u00f6zelliklerin otomatik olarak do\u011frulanmas\u0131n\u0131 sa\u011flar.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-485\" src=\"https:\/\/benlongkj.com\/wp-content\/uploads\/2026\/06\/2025-Guide-How-to-Effectively-Test-VCB-Breaker-Testing-Machines.webp\" alt=\"2025 K\u0131lavuzu: VCB Kesici Test Cihazlar\u0131 Nas\u0131l Etkili Bir \u015eekilde Test Edilir?\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>VCB kesici test cihazlar\u0131 i\u00e7in be\u015f temel test<\/h2>\n<p>T\u00fcm VCB\u2019lerde kapsaml\u0131 bir kesici testi i\u00e7in be\u015f adet do\u011frulama i\u015flemi ger\u00e7ekle\u015ftirilmelidir. Her bir ekipman par\u00e7as\u0131, ya her bir par\u00e7a test edildikten sonra bir kez ya da IEC 62271-100 standard\u0131nda belirtilenlere g\u00f6re d\u00fczenli aral\u0131klarla bu do\u011frulama i\u015flemlerinden ge\u00e7melidir.<\/p>\n<h3>Vakum s\u0131zd\u0131rmazl\u0131k testi (s\u0131z\u0131nt\u0131 tespiti)<\/h3>\n<p><span style=\"color: #ff0000;\">\u00d6l\u00e7t\u00fc\u011f\u00fc de\u011fer:<\/span> Vakum kesicinin bas\u0131nc\u0131, denetimden ge\u00e7ebilmesi i\u00e7in 1,33 x 10\u207b\u00b3 Pa'dan d\u00fc\u015f\u00fck olmal\u0131d\u0131r. Bu test, bir magnetron veya y\u00fcksek gerilim vakum test cihaz\u0131 kullan\u0131larak, y\u00fcksek gerilim (70 kV'a kadar) uygulan\u0131p kesme kontaklar\u0131ndan ge\u00e7en emisyon ak\u0131m\u0131 \u00f6l\u00e7\u00fclerek ger\u00e7ekle\u015ftirilir. Ak\u0131m e\u015fik seviyesini a\u015farsa (yani 12 kV vakum kesicide 10 \u00b5A veya daha az), vakum bozulmu\u015f demektir. Test, belirlenen s\u0131n\u0131rlar\u0131n d\u0131\u015f\u0131nda s\u00fcrekli de\u015farj veya X-\u0131\u015f\u0131n\u0131 emisyonu olmad\u0131\u011f\u0131 takdirde kabul edilmelidir.<\/p>\n<p>Bu testler s\u0131ras\u0131nda s\u0131k\u00e7a yap\u0131lan bir hata, testlerin hem ortam ko\u015fullar\u0131nda hem de (m\u00fcmk\u00fcnse) bir \u0131s\u0131 d\u00f6ng\u00fcs\u00fcnden sonra yap\u0131lmamas\u0131d\u0131r. Testlerin yaln\u0131zca ortam ko\u015fullar\u0131nda yap\u0131lmas\u0131, hatal\u0131 test sonu\u00e7lar\u0131na yol a\u00e7ar.<\/p>\n<h3>Mekanik \u00f6zellik testi (hareket mesafesi, h\u0131z, zamanlama)<\/h3>\n<p><span style=\"color: #ff0000;\">\u00d6l\u00e7t\u00fc\u011f\u00fc de\u011fer:<\/span> Hareket t\u00fcrleri aras\u0131nda temas (strok), a\u015f\u0131r\u0131 hareket, a\u00e7\u0131lma s\u00fcresi, kapanma s\u00fcresi ve ortalama hareket h\u0131z\u0131 yer al\u0131r.<br \/>\nSeyir Testlerinin Yap\u0131lmas\u0131: Bir VCB Test Seti, hareketli konta\u011fa bir do\u011frusal sens\u00f6r takar ve kesiciyi a\u00e7ma\/kapama komutu g\u00f6nderir. Sonu\u00e7lar e\u011fri grafikler halinde kaydedilir. 12 kV'luk bir VCB i\u00e7in, 8-12 mm'lik bir a\u00e7ma kontak stroku, 30-60 ms'lik bir a\u00e7ma s\u00fcresi ve 50-80 ms'lik bir kapama s\u00fcresi kabul edilmelidir.<br \/>\nSeyahat Testlerinin \u00d6nemi: Yava\u015f a\u00e7\u0131lma a\u015f\u0131r\u0131 ark enerjisine yol a\u00e7arken, h\u0131zl\u0131 kapanma kontaklar\u0131n z\u0131plamas\u0131na veya birbirine yap\u0131\u015fmas\u0131na neden olur.<\/p>\n<h3>Y\u00fcksek gerilim yal\u0131t\u0131m testi (dayan\u0131m gerilimi)<\/h3>\n<p><span style=\"color: #ff0000;\">\u00d6l\u00e7t\u00fc\u011f\u00fc de\u011fer:<\/span> Kesici ve yal\u0131t\u0131m destekleri, dielektrik dayan\u0131m testlerine tabi tutulur.<br \/>\nBu i\u015flem nas\u0131l yap\u0131l\u0131r? A\u00e7\u0131k kontaklar aras\u0131nda; her bir kutup ile toprak aras\u0131nda 60 saniye boyunca 42 kV (24 kV VCB i\u00e7in) veya 28 kV (12 kV VCB i\u00e7in) gerilim uygulan\u0131r. \u00dcretici s\u0131n\u0131r\u0131ndan (genellikle &lt;2 mA) daha b\u00fcy\u00fck bir flashover veya ka\u00e7ak ak\u0131m olmamal\u0131d\u0131r. (Otomasyon notu: \u00fcretim hatt\u0131ndaki s\u0131ral\u0131 yal\u0131t\u0131m test cihazlar\u0131 (VCB otomatik \u00fcretim hatt\u0131ndakiler gibi), montaj\u0131n sonunda her birimde 100% testi olarak bu testi ger\u00e7ekle\u015ftirir.)<\/p>\n<h3>Temas direnci (d\u00f6ng\u00fc direnci) testi<\/h3>\n<p><strong>\u00d6l\u00e7t\u00fc\u011f\u00fc de\u011fer:<\/strong> Terminaller aras\u0131 kapal\u0131 birincil devre direnci (vakum kesici dahil). A\u015fa\u011f\u0131dakileri uygulay\u0131n: mikro-ohmmetre (DC 50 \u2013 100A) kullan\u0131n. VCB'ler i\u00e7in, \u2018yeni\u2019 \u00fcnitelerde kabul edilebilir d\u00f6ng\u00fc direnci genellikle 50 mikro-ohm'dan az, hizmet halindekilerde ise 100 mikro-ohm'dan az olmal\u0131d\u0131r.<\/p>\n<p>Y\u00fckselen bir diren\u00e7 e\u011filiminin yorumlanmas\u0131, temas y\u00fczeylerinde a\u015f\u0131nma ya da mekanik ba\u011flant\u0131da hizas\u0131zl\u0131k oldu\u011funu g\u00f6sterir.<\/p>\n<h3>Mekanik dayan\u0131kl\u0131l\u0131k (\u00f6m\u00fcr) testi<\/h3>\n<p><strong>\u00d6l\u00e7t\u00fc\u011f\u00fc de\u011fer:<\/strong> Bu test, bir cihaz\u0131n ar\u0131za vermeden \u00e7ok say\u0131da mekanik i\u015fleme dayanma kabiliyetini \u00f6l\u00e7er. Test y\u00f6ntemi, devre kesiciyi belirli say\u0131da (IEC 62271-100'de belirtildi\u011fi gibi; M1 \u2013 10.000 d\u00f6ng\u00fc; M2 \u2013 30.000 d\u00f6ng\u00fc) a\u00e7\u0131p kapatacak otomatik bir test sisteminin kullan\u0131lmas\u0131n\u0131 i\u00e7erir. Bu i\u015flem s\u0131ras\u0131nda test sistemi \u015fu parametreleri \u00f6l\u00e7er: a\u00e7\u0131lma s\u00fcresi, kapanma s\u00fcresi ve kesicinin kontaklar\u0131ndaki a\u015f\u0131nma. Bir devre kesici 10.000 kez test edildi\u011finde, a\u00e7\u0131lma s\u00fcresinde 5%'den az bir art\u0131\u015f olmas\u0131 beklenir.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-488\" src=\"https:\/\/benlongkj.com\/wp-content\/uploads\/2026\/06\/How-to-choose-and-validate-a-VCB-breaker-testing-machine.webp\" alt=\"VCB kesici test cihaz\u0131 nas\u0131l se\u00e7ilir ve do\u011frulan\u0131r?\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>VCB kesici test cihaz\u0131 nas\u0131l se\u00e7ilir ve do\u011frulan\u0131r?<\/h2>\n<p>Bir kesici test cihaz\u0131 se\u00e7erken, a\u015fa\u011f\u0131daki \u00f6zelliklerin \u00fcretim ortam\u0131nda VCB'lerle kullan\u0131m veya saha bak\u0131m\u0131 i\u00e7in uygun oldu\u011fu dikkate al\u0131nmal\u0131d\u0131r:<\/p>\n<ul>\n<li><strong>Vakum test cihaz\u0131 serisi:<\/strong> 1\u00d710\u207b\u00b2 Pa'dan y\u00fcksek (s\u0131z\u0131nt\u0131l\u0131) ve 1\u00d710\u207b\u2074 Pa'dan d\u00fc\u015f\u00fck (sorunsuz) bas\u0131n\u00e7lar\u0131 alg\u0131layabilmelidir.<\/li>\n<li><strong>Hacimsel sens\u00f6r hassasiyeti:<\/strong> Strok \u00f6l\u00e7\u00fcm\u00fc i\u00e7in \u2264\u00b10,1 mm.<\/li>\n<li><strong>Gerilim dayan\u0131kl\u0131l\u0131\u011f\u0131:<\/strong> 12\u201324 kV'luk VCB'ler i\u00e7in en az 70 kV.<\/li>\n<li><strong>Veri kayd\u0131:<\/strong> Her test i\u00e7in e\u011frileri kaydetmeli ve bunlar\u0131 CSV dosyas\u0131na veya do\u011frudan MES sistemine aktarmal\u0131d\u0131r.<\/li>\n<li><strong>Uyum:<\/strong> IEC 62271-100 ekine (denetim k\u0131lavuzlar\u0131) uygun olarak \u00fcretilmi\u015ftir.<\/li>\n<\/ul>\n<p>Benlong Automation'a g\u00f6re, \u00fcretim hatt\u0131 yukar\u0131daki testleri tek bir kesintisiz s\u00fcre\u00e7te birle\u015ftiriyor ve t\u00fcm VCB'lerin (Vakumlu Devre Kesiciler) fabrikadan \u00e7\u0131kmadan \u00f6nce 100% modeliyle otomatik olarak test edilmesini sa\u011fl\u0131yor.<\/p>\n<h2>VCB testlerinde s\u0131k\u00e7a yap\u0131lan hatalar ve bunlar\u0131n nas\u0131l \u00f6nlenece\u011fi<\/h2>\n<ul>\n<li>Hata 1: Vakum sisteminin s\u0131zd\u0131rmazl\u0131\u011f\u0131n\u0131n kontrol\u00fc i\u00e7in geleneksel olarak bir megger (izolasyon test cihaz\u0131) kullan\u0131l\u0131rd\u0131. Bu y\u00f6ntem, topraklamaya (topra\u011fa) de\u011fil, a\u00e7\u0131k kontaklara y\u00fcksek gerilim (AC veya DC) uygulayan ba\u011f\u0131ms\u0131z bir vakum test cihaz\u0131 kullan\u0131larak iyile\u015ftirilebilir.<\/li>\n<li>Hata 2: Temas hareket e\u011frilerinin kaydedilmemesi: Tek bir \u201cvuru\u015f\u201d de\u011feri yeterli de\u011fildir. S\u0131\u00e7rama, a\u015f\u0131r\u0131 hareket ve temas titre\u015fimini g\u00f6sterdi\u011fi i\u00e7in her zaman hareket-zaman e\u011frisinin tamam\u0131n\u0131 kaydetmelisiniz.<\/li>\n<li>Hata 3<strong>:<\/strong> Temas direnci i\u00e7in s\u0131cakl\u0131k d\u00fczeltmesi dikkate al\u0131nmam\u0131\u015ft\u0131r. Bak\u0131rda elektrik direnci, her 1 \u00b0C'de 0,41 TP3T de\u011fi\u015fir. \u00c7\u00f6z\u00fcm: S\u0131cakl\u0131\u011f\u0131 \u00f6l\u00e7\u00fcn veya de\u011feri 20 \u00b0C referans noktas\u0131na g\u00f6re ayarlay\u0131n.<\/li>\n<\/ul>\n<h2>S\u0131k\u00e7a sorulan sorular (SSS)<\/h2>\n<h3>VCB testi nedir?<\/h3>\n<p><strong>VCB testi<\/strong> Bu, bir vakumlu kesicinin ar\u0131za ak\u0131mlar\u0131n\u0131 g\u00fcvenli bir \u015fekilde kesme ve normal \u00e7al\u0131\u015fma gerilimlerine dayanma yetene\u011fini do\u011frulamak amac\u0131yla ger\u00e7ekle\u015ftirilen elektriksel ve mekanik do\u011frulama test programlar\u0131n\u0131n eksiksiz bir setidir. Bu koleksiyon d\u00f6rt testten olu\u015fur: vakum b\u00fct\u00fcnl\u00fc\u011f\u00fc testi (hava s\u0131z\u0131nt\u0131lar\u0131n\u0131 tespit etme), yal\u0131t\u0131m dayan\u0131m gerilimi testi, kontak direnci \u00f6l\u00e7\u00fcm\u00fc ve mekanik \u00f6zellik testleri (a\u00e7\u0131lma\/kapanma s\u00fcreleri, strok, h\u0131z). Bu testler IEC 62271\u2011100 standard\u0131nda tan\u0131mlanm\u0131\u015ft\u0131r, tip testi kapsam\u0131nda zorunludur ve genellikle \u00fcretim rutin testleri olarak ger\u00e7ekle\u015ftirilir.<\/p>\n<h3>VCB ne i\u00e7in kullan\u0131l\u0131r?<\/h3>\n<p>Maksimum gerilimi 40,5 kV olan MV (Orta Gerilim) elektrik devrelerinin anahtarlama ve koruma i\u015flemlerinde VCB\u2019lerin (Vakumlu Kesiciler) kullan\u0131m\u0131, \u00f6ncelikle a\u015fa\u011f\u0131daki uygulamalar i\u00e7indir: (1) End\u00fcstriyel tesislerdeki birincil da\u011f\u0131t\u0131m sistemleri (2) Elektrik da\u011f\u0131t\u0131m trafo merkezleriyle ili\u015fkili \u015falt sistemleri (3) Demiryolu elektrifikasyon sistemleri (25 kV AC) (4) R\u00fczgar t\u00fcrbini jenerat\u00f6rleri (5) Kondansat\u00f6r bankalar\u0131. VCB'lerin tercih edilmesinin nedeni, bak\u0131m gerektirmemeleri (yani ya\u011f ve SF6 i\u00e7ermemeleri), \u00e7ok uzun elektriksel \u00f6m\u00fcrleri (\u00e7al\u0131\u015fma s\u00fcresi) (30.000 devre) ve sa\u011flam g\u00fcvenilirlikleridir.<\/p>\n<h3>VCB nas\u0131l kontrol edilir?<\/h3>\n<p>Bir VCB'yi kontrol etmek i\u00e7in \u00f6zel bir <strong>Kesici Testi<\/strong> ayarlay\u0131n. Ad\u0131m ad\u0131m prosed\u00fcr \u015f\u00f6yledir:<\/p>\n<ol>\n<li>VCB'yi devre d\u0131\u015f\u0131 b\u0131rak\u0131n ve t\u00fcm kapasitif y\u00fck\u00fc bo\u015falt\u0131n (kilitleme\/etiketleme prosed\u00fcrlerini uygulay\u0131n).<\/li>\n<li>Vakum kesici cam\u0131nda veya seramik k\u0131l\u0131f\u0131nda \u00e7atlak olup olmad\u0131\u011f\u0131n\u0131 g\u00f6zle kontrol edin.<\/li>\n<li>Magnetronlu bir y\u00fcksek gerilim test cihaz\u0131 kullanarak vakum s\u0131zd\u0131rmazl\u0131k testi yap\u0131n; kontaklar \u00fczerinden daha y\u00fcksek gerilimler uygulay\u0131n ve olas\u0131 s\u0131z\u0131nt\u0131lar\u0131 izleyin.<\/li>\n<li>Temas direncini bir mikroohmmetre (50\u2013100 A DC) ile \u00f6l\u00e7\u00fcn.<\/li>\n<li>Hareket sens\u00f6r\u00fc yard\u0131m\u0131yla toplam a\u00e7\u0131lma s\u00fcresi, toplam kapanma s\u00fcresi, strok uzunlu\u011fu ve ortalama h\u0131z\u0131 kaydederek mekanik \u00e7al\u0131\u015fma testi ger\u00e7ekle\u015ftirin.<\/li>\n<li>\u0130ki faz aras\u0131nda ve ayr\u0131ca faz ile toprak aras\u0131nda bir y\u00fcksek gerilim yal\u0131t\u0131m testi (yani, \u015febeke frekans\u0131 dayan\u0131m gerilimi testi) ger\u00e7ekle\u015ftirin.<\/li>\n<\/ol>\n<p>T\u00fcm sonu\u00e7lar, \u00fcreticinin teknik \u00f6zellik belgesiyle veya IEC 62271-100 kabul kriterleriyle kar\u015f\u0131la\u015ft\u0131r\u0131lmal\u0131d\u0131r.<\/p>\n<h3>Elektrik alan\u0131nda VCB ne anlama gelir?<\/h3>\n<p>Elektrik m\u00fchendisli\u011fi alan\u0131nda, \u201cVakumlu Devre Kesiciler\u201d anlam\u0131na gelen VCB gibi terimler yer al\u0131r. Vakumlu devre kesici, bir ar\u0131za durumunda elektrik devresini \u00e7ok h\u0131zl\u0131 bir \u015fekilde kesebilecek \u015fekilde tasarlanm\u0131\u015f bir elektrik anahtar\u0131d\u0131r; b\u00f6ylece hatlar\u0131n veya elektrikli cihazlar\u0131n a\u015f\u0131r\u0131 ak\u0131mdan zarar g\u00f6rmesini \u00f6nlemeye yard\u0131mc\u0131 olur. Bu cihazlar, iki ayr\u0131 kontak grubunu ( \u201csabit\u201d kontak ve \u201chareketli\u201d kontak) i\u00e7eren seramik veya cam bir muhafaza kullanarak \u00e7al\u0131\u015f\u0131r; kontaklar g\u00fc\u00e7 birikimi veya a\u015f\u0131r\u0131 ak\u0131m nedeniyle birbirinden ayr\u0131ld\u0131\u011f\u0131nda (yukar\u0131daki \u00f6rnekte oldu\u011fu gibi), iki kontak seti aras\u0131nda milisaniyeler i\u00e7inde s\u00f6nen anl\u0131k bir elektrik ark\u0131 olu\u015fur. Bu nedenle, bu t\u00fcr elektrikli cihazlar 3,6 kV ile 40,5 kV aras\u0131ndaki gerilimlerdeki uygulamalarda (buna \u201cOrta Gerilim\u201d uygulamalar\u0131 denir) yayg\u0131n olarak kullan\u0131l\u0131r.<\/p>\n<p>2025 y\u0131l\u0131nda VCB'lerin test edilmesinde do\u011fru yakla\u015f\u0131m, vakumun, mekanik par\u00e7alar\u0131n, yal\u0131t\u0131m kapasitesinin, temas direncinin ve mekanik dayan\u0131kl\u0131l\u0131\u011f\u0131n b\u00fct\u00fcnsel b\u00fct\u00fcnl\u00fc\u011f\u00fcn\u00fc de\u011ferlendirmek i\u00e7in sistematik bir y\u00f6nteme sahip olmay\u0131 gerektirir. T\u00fcm testlerde, magnetron vakum test cihaz\u0131, hareket transd\u00fcseri, mikro-ohmmetre ve y\u00fcksek gerilim seti dahil olmak \u00fczere uygun test ekipmanlar\u0131 kullan\u0131lmal\u0131 ve sonu\u00e7lar IEC 62271-100 standard\u0131na g\u00f6re yorumlanmal\u0131d\u0131r. VCB'lerin y\u00fcksek hacimli \u00fcretimi i\u00e7in, yeni tam otomatik VCB \u00fcretim hatt\u0131 gibi entegre Kesici Test Hatlar\u0131 mevcuttur. Bu hatlar, yukar\u0131daki 5 testin her birini g\u00fcvenilir ve tutarl\u0131 bir \u015fekilde otomatikle\u015ftirerek 100% denetimini ve veri izlenebilirli\u011fini sa\u011flar ve g\u00fcnl\u00fck olarak vardiya ba\u015f\u0131na 25-30 adet VCB \u00fcretir. \u0130ster bir kamu hizmeti \u015firketinde m\u00fchendis olarak \u00e7al\u0131\u015f\u0131yor olun, ister VCB'lerin \u00fcretiminden ve testinden sorumlu olun, bu belge, yukar\u0131daki VCB Test Hatalar\u0131ndan herhangi biri meydana geldi\u011finde maliyetli sonu\u00e7lar\u0131 \u00f6nleyebilmenizi sa\u011flamak amac\u0131yla sunulmu\u015ftur.<\/p>","protected":false},"excerpt":{"rendered":"<p>Field failure cost: An undetected vacuum leak on a 24KV VCB led to failure to interrupt a short circuit. This substation outage cost our utility company more than $200,000, and we missed it due to our testing procedures. \u2013 Maintenance engineer, regional utility company. Testing a VCB breaker is not the same as testing a [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":485,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-482","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/posts\/482","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/comments?post=482"}],"version-history":[{"count":3,"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/posts\/482\/revisions"}],"predecessor-version":[{"id":489,"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/posts\/482\/revisions\/489"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/media\/485"}],"wp:attachment":[{"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/media?parent=482"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/categories?post=482"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/benlongkj.com\/tr\/wp-json\/wp\/v2\/tags?post=482"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}