{"id":27,"date":"2026-06-01T10:37:36","date_gmt":"2026-06-01T10:37:36","guid":{"rendered":"https:\/\/khkrh7q1ur.wpdns.site\/product\/auxiliary-and-signal-contact-test-bench\/"},"modified":"2026-06-10T07:29:08","modified_gmt":"2026-06-10T07:29:08","slug":"auxiliary-and-signal-contact-test-bench-product","status":"publish","type":"product","link":"https:\/\/benlongkj.com\/pt\/auxiliary-and-signal-contact-test-bench-product\/","title":{"rendered":"Bancada de testes de contato auxiliar e de sinal"},"content":{"rendered":"<div class=\"bl-pdp-wrapper\">\n<div class=\"bl-pdp-split\">\n<div class=\"bl-pdp-split-text\">\n<div class=\"bl-pdp-badge\">L\u00f3gica de modo duplo \u00b7 Resist\u00eancia de contacto<\/div>\n<h1>Bancada de ensaio de contactos auxiliares e de sinaliza\u00e7\u00e3o para RCBO\/MCB<\/h1>\n<p>Os testes automatizados e manuais dos contactos auxiliares e dos contactos de alarme (ou sinais) s\u00e3o realizados em bancada. A bancada ir\u00e1 confirmar que o estado do contacto mudou de normal para inverso (ou vice-versa) sempre que a alavanca do disjuntor for aberta ou fechada manualmente (verificar o estado de um contacto auxiliar sempre que uma pessoa abrir ou fechar manualmente a alavanca do disjuntor). A bancada confirmar\u00e1 que o estado do contacto N\u00c3O se alterar\u00e1 enquanto o disjuntor estiver a ser aberto manualmente (verificar o estado de um contacto de alarme enquanto uma pessoa estiver a abrir manualmente o disjuntor) nem se alterar\u00e1 quando ocorrer uma falha, mas ALTERAR\u00c1 de estado quando for simulado um disparo por falha. (A simula\u00e7\u00e3o \u00e9 realizada atrav\u00e9s do bot\u00e3o de teste do RCBO ou da cria\u00e7\u00e3o de um curto-circuito total.) O banco de ensaio medir\u00e1 tamb\u00e9m a resist\u00eancia do contacto auxiliar utilizando um micro-ohm\u00edmetro e realizar\u00e1 testes de alta tens\u00e3o para confirmar que n\u00e3o ocorre corrente de fuga. O banco de ensaio \u00e9 adequado para laborat\u00f3rios de controlo de qualidade e linhas de produ\u00e7\u00e3o, bem como para a inspe\u00e7\u00e3o \u00e0 entrada de um m\u00f3dulo de contacto auxiliar.<\/p>\n<p><span style=\"color: #2872fa; font-weight: 500;\">Entrega padr\u00e3o: 30-45 dias | Testes l\u00f3gicos de modo duplo | Resist\u00eancia de contacto e teste de alta tens\u00e3o<\/span><\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-split-media\">\n            <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Auxiliary-and-Signal-Contact-test-bench.webp\" alt=\"Banco de teste de contato auxiliar e de sinal\"><\/p>\n<div style=\"font-size: 11px; margin-top: 8px;\">Esta\u00e7\u00e3o de teste de contacto de modo duplo (produto real)<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-definition\">\n<h2>Que problemas resolve esta bancada de ensaio?<\/h2>\n<p>Os contactos auxiliares\/de sinal s\u00e3o componentes essenciais na monitoriza\u00e7\u00e3o remota de disjuntores. No entanto, existem tr\u00eas problemas principais comuns tanto aos fabricantes como aos utilizadores de disjuntores: l\u00f3gica de comuta\u00e7\u00e3o incorreta (por exemplo, o disparo do alarme aquando da abertura manual, o que gera falsos alarmes); alta resist\u00eancia de contacto (a oxida\u00e7\u00e3o dos contactos resulta na perda de transmiss\u00e3o do sinal); e quebra de isolamento (o que pode constituir um problema de seguran\u00e7a). O banco de ensaio resolver\u00e1 estes tr\u00eas problemas atrav\u00e9s de uma sequ\u00eancia testada para validar a l\u00f3gica de modo duplo (Auxiliar vs. Alarme) e medir a resist\u00eancia de contacto (para identificar disjuntores avariados).<\/p>\n<div class=\"bl-pdp-feature-grid\">\n<div class=\"bl-pdp-feature-card\">\n                <strong>Verifica\u00e7\u00e3o l\u00f3gica de modo duplo<\/strong><\/p>\n<p>Teste o modo auxiliar (os contactos alteram-se com a manivela) e o modo de alarme (os contactos s\u00f3 se alteram em caso de desligamento por falha e n\u00e3o em caso de abertura manual).<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Medi\u00e7\u00e3o da resist\u00eancia de contacto<\/strong><\/p>\n<p>Mede a resist\u00eancia dos contactos fechados (&lt;50 m\u03a9, valor t\u00edpico) \u2013 deteta oxida\u00e7\u00e3o ou mau contacto que possam causar falhas no sinal.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Ensaio de resist\u00eancia diel\u00e9trica (hi-pot)<\/strong><\/p>\n<p>Aplica 1500 V ou 2000 V CA entre os terminais para verificar a integridade do isolamento, de acordo com a norma IEC 60947\u20115\u20111.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Verifica\u00e7\u00e3o do bloqueio mec\u00e2nico<\/strong><\/p>\n<p>Verifica o encaixe e o funcionamento corretos do contacto auxiliar\/de sinaliza\u00e7\u00e3o quando montado num RCBO\/MCB.<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery\">\n<h2>Processo de teste e vantagens para o cliente<\/h2>\n<div class=\"bl-pdp-gallery-grid\">\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Intelligence-Visibility.webp\" alt=\"Visibilidade Inteligente - monitoramento em tempo real\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Informa\u00e7\u00e3o e visibilidade \u2013 visualiza\u00e7\u00e3o em tempo real do estado dos contactos (NO\/NC) e dos par\u00e2metros de teste<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Efficiency-Sustainability.webp\" alt=\"Efici\u00eancia e Sustentabilidade - economia de energia\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Efici\u00eancia e sustentabilidade \u2013 a sequ\u00eancia de testes automatizada reduz o tempo de testes manuais em 80%<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Design-Integration.webp\" alt=\"Integra\u00e7\u00e3o de projeto - engenharia modular\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Conce\u00e7\u00e3o e integra\u00e7\u00e3o \u2013 suporte universal para diferentes modelos de contactos auxiliares<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Safety-Reliability.webp\" alt=\"Seguran\u00e7a e confiabilidade - testes rigorosos\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Seguran\u00e7a e fiabilidade \u2013 \u00e1rea fechada para testes de alta tens\u00e3o com sistema de interbloqueio que protege o operador<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<h2>Especifica\u00e7\u00f5es t\u00e9cnicas<\/h2>\n<div class=\"bl-pdp-summary\">Banco de ensaio para contactos auxiliares e de alarme. L\u00f3gica de modo duplo (Auxiliar\/Alarme), resist\u00eancia dos contactos (&lt;50 m\u03a9), ensaio de alta tens\u00e3o (1500 V\/2000 V CA), verifica\u00e7\u00e3o do interbloqueio mec\u00e2nico.<\/div>\n<div class=\"bl-pdp-table-wrap\">\n<table class=\"bl-pdp-table\">\n<tbody>\n<tr>\n<th style=\"width: 35%;\">Fun\u00e7\u00f5es de teste<\/th>\n<td>L\u00f3gica do modo auxiliar, l\u00f3gica do modo de alarme, resist\u00eancia de contacto, rigidez diel\u00e9trica (hi-pot), interbloqueio mec\u00e2nico\n                <\/td>\n<\/tr>\n<tr>\n<th>Medi\u00e7\u00e3o da resist\u00eancia de contacto<\/th>\n<td>Intervalo de 0 a 200 m\u03a9, precis\u00e3o de \u00b11%, corrente de teste de 1 A CC (micro-ohm\u00edmetro)\n                <\/td>\n<\/tr>\n<tr>\n<th>Aceita\u00e7\u00e3o da resist\u00eancia de contacto<\/th>\n<td>&lt;50 m\u03a9 (t\u00edpico), limite program\u00e1vel\n                <\/td>\n<\/tr>\n<tr>\n<th>Tens\u00e3o de ensaio de alta tens\u00e3o<\/th>\n<td>1500 V CA \/ 2000 V CA (program\u00e1vel, 1 a 60 segundos)\n                <\/td>\n<\/tr>\n<tr>\n<th>Limiar de corrente de fuga<\/th>\n<td>Program\u00e1vel (por exemplo, 5 mA, 10 mA)\n                <\/td>\n<\/tr>\n<tr>\n<th>Teste do modo auxiliar<\/th>\n<td>Opera\u00e7\u00e3o manual da alavanca (fechar\/abrir) \u2013 verifica\u00e7\u00e3o autom\u00e1tica da continuidade nos contactos NO\/NC\n                <\/td>\n<\/tr>\n<tr>\n<th>Teste do modo de alarme \u2013 abertura manual<\/th>\n<td>O contacto N\u00c3O deve alterar o seu estado\n                <\/td>\n<\/tr>\n<tr>\n<th>Teste do modo de alarme \u2013 simula\u00e7\u00e3o de desligamento por falha<\/th>\n<td>O contacto deve mudar de estado (NO \u2192 fechado, NC \u2192 aberto) instantaneamente\n                <\/td>\n<\/tr>\n<tr>\n<th>M\u00e9todo de simula\u00e7\u00e3o de disparo por falha<\/th>\n<td>Para o RCBO: press\u00e3o autom\u00e1tica do bot\u00e3o \u201cT\u201d; para o MCB: inje\u00e7\u00e3o de corrente de curto-circuito (opcional)\n                <\/td>\n<\/tr>\n<tr>\n<th>Fonte de energia<\/th>\n<td>220 V \u00b110% 50 Hz\n                <\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<h2>Principais vantagens para o cliente \u2013 Por que raz\u00e3o os fabricantes utilizam esta bancada<\/h2>\n<div class=\"bl-pdp-grid\">\n<div class=\"bl-pdp-card\">\n<h4>Vantagem 1: Elimina os falsos alarmes no terreno<\/h4>\n<p>Os contactos de alarme s\u00f3 ser\u00e3o testados para verificar se funcionam corretamente (ou seja, os contactos de alarme) quando ocorrer uma avaria real (por exemplo, ao premir o bot\u00e3o de teste do RCBO ou ao simular um curto-circuito). Ser\u00e3o tamb\u00e9m testados corretamente quando o disjuntor for aberto manualmente, sem provocar um falso alarme, o que ajudar\u00e1 a eliminar o desperd\u00edcio de recursos necess\u00e1rios para reparar falsos alarmes que criam incerteza entre os clientes quanto \u00e0 fiabilidade dos seus equipamentos.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Vantagem 2: Deteta a oxida\u00e7\u00e3o dos contactos antes de esta provocar uma avaria<\/h4>\n<p>As devolu\u00e7\u00f5es no terreno e as chamadas de assist\u00eancia s\u00e3o dispendiosas para os fabricantes; a medi\u00e7\u00e3o de uma elevada resist\u00eancia de contacto (50 m\u03a9) provoca intermit\u00eancia ou perda do sinal. Os fabricantes detetam este sinal intermitente e procedem \u00e0 repara\u00e7\u00e3o do equipamento antes de este ser devolvido a um centro de assist\u00eancia.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Vantagem 3: Garante a integridade do isolamento para maior seguran\u00e7a<\/h4>\n<p>Um ensaio de rigidez diel\u00e9trica \u00e9 realizado aplicando a alta tens\u00e3o especificada (1500 V ou 2000 V) entre os terminais e verificando se h\u00e1 falhas no isolamento, bem como corrente de fuga. Consequentemente, o ensaio de rigidez diel\u00e9trica \u00e9 especialmente importante para dispositivos que possuem contactos auxiliares ligados a PLCs de baixa tens\u00e3o ou a circuitos de controlo, uma vez que qualquer falha no material isolante pode resultar em danos em equipamento de automa\u00e7\u00e3o muito dispendioso ou criar um risco de choque el\u00e9trico.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Vantagem 4: Testes r\u00e1pidos e repet\u00edveis<\/h4>\n<p>Ao automatizar a sequ\u00eancia de testes l\u00f3gicos em modo duplo, os testes em bancada podem agora concluir a valida\u00e7\u00e3o\/teste de um m\u00f3dulo de contacto auxiliar em menos de 30 segundos, em compara\u00e7\u00e3o com os v\u00e1rios minutos necess\u00e1rios para os testes manuais com mult\u00edmetro. Um \u00fanico operador pode testar centenas destes m\u00f3dulos durante um turno e os resultados repet\u00edveis ser\u00e3o consistentes com a precis\u00e3o 100%.<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-partners\">\n        <span class=\"bl-pdp-partners-title\">Aprovado pelos l\u00edderes do setor<\/span><\/p>\n<div class=\"bl-pdp-partners-list\">\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738413289.webp\" alt=\"ABB\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594739263598.webp\" alt=\"DELICIOSO\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594739675877.webp\" alt=\"EKF\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594741141751.webp\" alt=\"KRIPAL\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738593989.webp\" alt=\"HPL\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738101609.webp\" alt=\"CHAC\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738124777.webp\" alt=\"Schneider\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738797907.webp\" alt=\"GRUPO IEK\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738812289.webp\" alt=\"SUNIR\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738411369.webp\" alt=\"Bevone\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738389707.webp\" alt=\"Weg\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738361034.webp\" alt=\"HUYU\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738416677.webp\" alt=\"RAAD\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738314557.webp\" alt=\"WALTONE\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738445639.webp\" alt=\"HAVELLS\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738720809.webp\" alt=\"C&amp;S el\u00e9trica\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-case\">\n<h3>Sucesso do Cliente \u2013 Eliminar devolu\u00e7\u00f5es por falsos alarmes<\/h3>\n<p>Uma empresa consolidada no setor dos RCBO tinha 5% das suas devolu\u00e7\u00f5es de campo direcionadas para m\u00f3dulos de contactos auxiliares, os quais geravam falsos alarmes quando o sistema era desligado manualmente. A empresa investigou a causa destes problemas e descobriu que a origem do problema residia em testes l\u00f3gicos inconsistentes durante a produ\u00e7\u00e3o. Posteriormente, introduziu uma bancada de testes de contactos auxiliares e de sinal com testes automatizados em modo duplo para verifica\u00e7\u00e3o l\u00f3gica e conseguiu:<\/p>\n<div class=\"bl-pdp-case-stats\">\n<div class=\"bl-pdp-case-stat\"><strong>0.1%<\/strong> Os falsos alarmes voltam (uma descida em rela\u00e7\u00e3o a 5%)<\/div>\n<div class=\"bl-pdp-case-stat\"><strong>100%<\/strong> Cobertura de teste para a resist\u00eancia l\u00f3gica e de contacto<\/div>\n<div class=\"bl-pdp-case-stat\"><strong>$200k\/ano<\/strong> Poupan\u00e7a em custos de garantia e de assist\u00eancia no local<\/div>\n<\/p><\/div>\n<p style=\"margin-top: 12px; font-size: 14px;\">A bancada recuperou os custos no prazo de 4 meses ap\u00f3s a compra, al\u00e9m de ser a principal esta\u00e7\u00e3o de testes para todos os contactos auxiliares produzidos.<\/p>\n<\/p><\/div>\n<h2>Aplica\u00e7\u00f5es \u2013 Onde este banco de trabalho acrescenta mais valor<\/h2>\n<div class=\"bl-pdp-feature\">\n<div class=\"bl-pdp-feature-list\">\n<div class=\"bl-pdp-feature-item\"><strong>Fabrico de contactos auxiliares<\/strong> \u2013 Testes finais de controlo de qualidade da l\u00f3gica de contacto, da resist\u00eancia e do isolamento<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Linhas de montagem de RCBO \/ MCB<\/strong> \u2013 Verifica\u00e7\u00e3o em linha dos contactos auxiliares\/de sinal montados<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Inspe\u00e7\u00e3o de entrada<\/strong> \u2013 Testar os m\u00f3dulos de contactos auxiliares adquiridos junto dos fornecedores<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Valida\u00e7\u00e3o de P&amp;D<\/strong> \u2013 Caracteriza\u00e7\u00e3o de novos modelos de contactos auxiliares<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<h2>Engenharia e entrega personalizadas<\/h2>\n<div class=\"bl-pdp-steps\">\n<div class=\"bl-pdp-step\"><strong>1. An\u00e1lise de amostras por contacto<\/strong> 7 a 15 dias \u00b7 m\u00f3dulo de contactos auxiliares\/de sinaliza\u00e7\u00e3o, RCBO\/MCB para instala\u00e7\u00e3o<\/div>\n<div class=\"bl-pdp-step\"><strong>2. Programa\u00e7\u00e3o de fixa\u00e7\u00f5es e l\u00f3gica<\/strong> 10-20 dias \u00b7 suporte universal, sequ\u00eancia de teste de modo duplo<\/div>\n<div class=\"bl-pdp-step\"><strong>3. Fabrica\u00e7\u00e3o e montagem<\/strong> 30 a 45 dias<\/div>\n<div class=\"bl-pdp-step\"><strong>4. Pr\u00e9-gordura<\/strong> Na f\u00e1brica de Benlong<\/div>\n<div class=\"bl-pdp-step\"><strong>5. Instala\u00e7\u00e3o e treinamento<\/strong> No local, 2 a 3 dias<\/div>\n<div class=\"bl-pdp-step\"><strong>6. SAT final<\/strong> 2 a 3 dias \u00b7 relat\u00f3rio de aceita\u00e7\u00e3o<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-cta\">\n<h2>Solicite um or\u00e7amento personalizado para uma bancada de ensaio de contactos auxiliares<\/h2>\n<p>Por favor, forne\u00e7a as especifica\u00e7\u00f5es de teste dos contactos auxiliares\/de sinal e amostras. Iremos conceber um banco de ensaio que inclua testes de modo duplo, de resist\u00eancia de contacto (baixo n\u00edvel) e de alta tens\u00e3o, e calcularemos o retorno do investimento (ROI).<\/p>\n<p>        <a class=\"bl-pdp-btn\" href=\"\/pt\/contact\/\">Consulte agora<\/a><\/p>\n<p class=\"bl-pdp-footnote\">WhatsApp: +86 150 5837 0007 | E-mail: xsb@benlongkj.cn | Suporte em ingl\u00eas e chin\u00eas<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-two-col\">\n<div class=\"bl-pdp-col-main\">\n<h3>Por que escolher a Benlong para bancadas de ensaio de contacto?<\/h3>\n<ul>\n<li>Mais de 15 anos de experi\u00eancia em design. <strong>equipamento de teste de contacto<\/strong> para componentes el\u00e9tricos de baixa tens\u00e3o<\/li>\n<li>Teste l\u00f3gico comprovado em modo duplo (Auxiliar vs. Alarme) \u2013 elimina os falsos alarmes<\/li>\n<li>Medi\u00e7\u00e3o integrada da resist\u00eancia de contacto (precis\u00e3o de \u00b11%) e ensaio de alta tens\u00e3o<\/li>\n<li>Suporte universal para v\u00e1rios modelos de contactos auxiliares<\/li>\n<li>Servi\u00e7o global e suporte de pe\u00e7as de reposi\u00e7\u00e3o<\/li>\n<\/ul><\/div>\n<div class=\"bl-pdp-col-side\">\n<h3>O banco padr\u00e3o inclui<\/h3>\n<p>Dispositivo universal de contacto de sinal auxiliar, com acionamento autom\u00e1tico da alavanca no modo auxiliar, simulador de desligamento por falha e\/ou atuador do bot\u00e3o de teste para inje\u00e7\u00e3o de curto-circuito. Microohm\u00edmetro para medi\u00e7\u00e3o da resist\u00eancia de contacto. Testador de CA de alta tens\u00e3o para 2000 V. PLC com IHM. Luzes indicadoras OK\/NG. Caixa de seguran\u00e7a. Manuais do utilizador. Certificados de calibra\u00e7\u00e3o. Garantia de 1 ano.<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-internal-links\">\n        <span class=\"bl-pdp-internal-links-title\">Solu\u00e7\u00f5es relacionadas<\/span><\/p>\n<div class=\"bl-pdp-links-list\">\n            <a href=\"https:\/\/benlongkj.com\/pt\/rcbo-semi-automatic-comprehensive-test-bench-product\/\">Banco de ensaios semi-autom\u00e1tico e abrangente para RCBO<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/pt\/mcb-automatic-testing-line\/\">Linha de teste autom\u00e1tico MCB<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/pt\/ac-contactor-comprehensive-test-machine-product\/\">M\u00e1quina de teste abrangente para contatores CA<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/pt\/mccb-semi-automatic-high-voltage-test-bench-product\/\">Bancada de teste de alta tens\u00e3o semiautom\u00e1tica MCCB<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/pt\/load-isolation-switch-automatic-testing-line-product\/\">Linha de teste de chave seccionadora de carga<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/pt\/mcb-handle-link-automatic-assembly-machine-product\/\">M\u00e1quina de montagem de elos de alavanca MCB<\/a>\n        <\/div>\n<\/p><\/div>\n<h2>Perguntas frequentes<\/h2>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Qual \u00e9 a diferen\u00e7a entre o modo auxiliar e o modo de alarme?<\/div>\n<p>Os contactos para o modo auxiliar mudam de estado a cada acionamento da alavanca do disjuntor, quer se trate de um acionamento manual (como a abertura ou o fecho) ou de uma indica\u00e7\u00e3o remota da posi\u00e7\u00e3o; n\u00e3o mudam de estado devido a um evento de disparo (falha), como uma sobrecarga ou um curto-circuito. Os contactos utilizados no modo de alarme indicam o estado do disjuntor no momento do disparo, causado por uma falha. O objetivo de testar o banco de ensaio em ambos os modos \u00e9 verificar o funcionamento esperado dos contactos.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Como \u00e9 que o banco de ensaio simula um disparo por falha para os testes no modo de alarme?<\/div>\n<p>No caso dos RCBOs, n\u00e3o \u00e9 necess\u00e1rio criar o circuito de teste, uma vez que o banco de ensaio realiza automaticamente o teste ao premir o bot\u00e3o T (teste) localizado na tampa do disjuntor. No caso dos MCBs, o banco de ensaio pode injetar uma corrente de curto-circuito ajust\u00e1vel para criar as condi\u00e7\u00f5es necess\u00e1rias ao funcionamento do mecanismo de disparo magn\u00e9tico; alternativamente, a utiliza\u00e7\u00e3o de um atuador mec\u00e2nico para acionar o mecanismo tamb\u00e9m exigir\u00e1 a cria\u00e7\u00e3o de um circuito de teste. A altera\u00e7\u00e3o do estado dos contactos \u00e9 verificada em tempo real.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Qual \u00e9 a resist\u00eancia de contacto aceit\u00e1vel para os contactos auxiliares?<\/div>\n<p>A norma IEC 60947\u20115\u20111 recomenda &lt;50 m\u03a9 para contactos novos. O equipamento permite definir um limite superior program\u00e1vel (por exemplo, 50 m\u03a9). Uma resist\u00eancia mais elevada indica oxida\u00e7\u00e3o, contamina\u00e7\u00e3o ou press\u00e3o de contacto insuficiente, o que pode levar a uma transmiss\u00e3o intermitente do sinal.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">A bancada suporta diferentes configura\u00e7\u00f5es de pinos de contacto (por exemplo, 11-12-14)?<\/div>\n<p>Sim. O suporte universal disp\u00f5e de sondas que podem ser ajustadas para se adaptarem a v\u00e1rias configura\u00e7\u00f5es de pinos. Assim que a receita do produto for selecionada, a sequ\u00eancia de teste determinar\u00e1 a configura\u00e7\u00e3o de pinos por si.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">O equipamento de ensaio pode testar simultaneamente contactos normalmente abertos e normalmente fechados?<\/div>\n<p>O banco de ensaios verifica a continuidade dos contactos NO e NC ao longo de toda a sequ\u00eancia de ensaio. No ensaio auxiliar, deve haver continuidade no contacto NO enquanto o disjuntor estiver na posi\u00e7\u00e3o ON e no contacto NC enquanto o disjuntor estiver na posi\u00e7\u00e3o OFF. O modo de alarme ir\u00e1 verificar se apenas o contacto adequado altera o seu estado quando ocorre um disparo por falha.<\/p>\n<\/p><\/div>\n<div style=\"margin: 32px 0 16px; font-size: 12px; text-align: center; border-top: 1px solid #e9edf2; padding-top: 16px; color: #5f7d9c;\">\n        Todas as especifica\u00e7\u00f5es est\u00e3o sujeitas a acordo t\u00e9cnico final. Benlong Automation \u2013 solu\u00e7\u00f5es de teste de contactos auxiliares e de sinal para fabricantes de RCBO e MCB.\n    <\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Banco de ensaio de contactos auxiliares e de sinaliza\u00e7\u00e3o para RCBO\/MCB. Testa a l\u00f3gica de modo duplo (auxiliar e alarme), a resist\u00eancia dos contactos (&lt;50 m\u03a9) e rigidez diel\u00e9trica (1500 V\/2000 V). Elimina falsos alarmes, deteta oxida\u00e7\u00e3o e garante a integridade do isolamento. Ideal para laborat\u00f3rios de controlo de qualidade e linhas de produ\u00e7\u00e3o. Em conformidade com a norma IEC 60947\u20115\u20111.\n<\/p>","protected":false},"featured_media":26,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[20],"product_tag":[],"class_list":["post-27","product","type-product","status-publish","has-post-thumbnail","product_cat-test-bench-project","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/benlongkj.com\/pt\/wp-json\/wp\/v2\/product\/27","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/benlongkj.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/benlongkj.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/pt\/wp-json\/wp\/v2\/comments?post=27"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/pt\/wp-json\/wp\/v2\/media\/26"}],"wp:attachment":[{"href":"https:\/\/benlongkj.com\/pt\/wp-json\/wp\/v2\/media?parent=27"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/benlongkj.com\/pt\/wp-json\/wp\/v2\/product_brand?post=27"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/benlongkj.com\/pt\/wp-json\/wp\/v2\/product_cat?post=27"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/benlongkj.com\/pt\/wp-json\/wp\/v2\/product_tag?post=27"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}