{"id":137,"date":"2026-06-01T10:38:55","date_gmt":"2026-06-01T10:38:55","guid":{"rendered":"https:\/\/khkrh7q1ur.wpdns.site\/product\/mcb-electrical-endurance-test-bench\/"},"modified":"2026-06-08T03:21:09","modified_gmt":"2026-06-08T03:21:09","slug":"mcb-electrical-endurance-test-bench-product","status":"publish","type":"product","link":"https:\/\/benlongkj.com\/pt\/mcb-electrical-endurance-test-bench-product\/","title":{"rendered":"Bancada de Teste de Resist\u00eancia El\u00e9trica MCB"},"content":{"rendered":"<div class=\"bl-pdp-wrapper\">\n<div class=\"bl-pdp-split\">\n<div class=\"bl-pdp-split-text\">\n<div class=\"bl-pdp-badge\">IEC 60898\u20111 Cl\u00e1usula 9.11 \u00b7 Resist\u00eancia El\u00e9trica<\/div>\n<h1>Bancada de Teste de Resist\u00eancia El\u00e9trica MCB<\/h1>\n<p>A bancada de testes de resist\u00eancia el\u00e9trica para disjuntores miniatura (MCB) \u00e9 um sistema de teste automatizado sofisticado, projetado para testar a vida \u00fatil el\u00e9trica e as caracter\u00edsticas de comuta\u00e7\u00e3o de disjuntores miniatura em configura\u00e7\u00f5es operacionais nominais, conforme as normas IEC 60898-1 (Cl\u00e1usula 9.11) e IEC 60947-2. A bancada mede a capacidade dos MCBs de suportar a abertura e o fechamento repetidos da conex\u00e3o el\u00e9trica sob uma fonte de alimenta\u00e7\u00e3o I\u2099 (corrente nominal) e U\u2099 (tens\u00e3o nominal). Durante esses testes, os contatos dos MCBs n\u00e3o devem soldar, apresentar arcos el\u00e9tricos excessivos ou mostrar sinais de falha mec\u00e2nica.<\/p>\n<p>Um sistema de atua\u00e7\u00e3o que pode ser operado com controle preciso de temporiza\u00e7\u00e3o e velocidade via servo com banco de carga program\u00e1vel indutivo-resistivo (LR) (cos \u03c6 = 0,85 \u00b1 0,05) com fator de pot\u00eancia e um CLP (Controlador L\u00f3gico Program\u00e1vel) que se comunica com um sistema de aquisi\u00e7\u00e3o de dados (DAQ) dedicado, o qual monitora a queda de tens\u00e3o no contato, a dura\u00e7\u00e3o do arco e o aumento de temperatura a cada ciclo. Um conjunto de sensores automatizados detecta falhas no disparo ou na soldagem do contato, acionando um desligamento de seguran\u00e7a. Todos os dados de teste, incluindo contagem de ciclos, forma de onda da corrente e registros de temperatura, s\u00e3o armazenados em um banco de dados na nuvem para rastreabilidade e conformidade completas.<\/p>\n<p><span style=\"color: #2872fa; font-weight: 500;\">Entrega padr\u00e3o: 45 a 60 dias | Ciclos de teste at\u00e9 20.000 | Em conformidade com a norma IEC 60898-1, cl\u00e1usula 9.11<\/span><\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-split-media\">\n            <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/electrical-life-test-main-image-1.png\" alt=\"MCB electrical endurance test bench\"><\/p>\n<div style=\"font-size: 11px; margin-top: 8px;\">Bancada de teste de vida \u00fatil el\u00e9trica com banco de carga L-R (produto real)<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-definition\">\n<h2>O que \u00e9 uma bancada de testes de resist\u00eancia el\u00e9trica MCB?<\/h2>\n<p>O objetivo de uma bancada de testes de resist\u00eancia el\u00e9trica para disjuntores miniatura (MCB) \u00e9 quantificar a vida \u00fatil de um disjuntor miniatura ap\u00f3s ser submetido a in\u00fameras opera\u00e7\u00f5es repetitivas de chaveamento. Ao contr\u00e1rio dos testes de ciclo de vida mec\u00e2nico, nos quais o disjuntor opera sem carga, os testes de resist\u00eancia el\u00e9trica operam sob condi\u00e7\u00f5es de carga, aplicando a corrente e a tens\u00e3o nominais durante cada ciclo de LIGAR e DESLIGAR. Isso testa o disjuntor miniatura de maneira semelhante \u00e0s condi\u00e7\u00f5es que ele encontraria em aplica\u00e7\u00f5es reais, durante as quais ocorrem arcos el\u00e9tricos, eros\u00e3o de contatos e tens\u00f5es t\u00e9rmicas. Como \u00e9 um requisito para testes de tipo, garantia da qualidade e certifica\u00e7\u00e3o de acordo com as normas IEC 60898-1 (Cl\u00e1usula 9.11) e IEC 60947-2, este equipamento \u00e9 uma parte importante do desenvolvimento e certifica\u00e7\u00e3o de um MCB. As caracter\u00edsticas t\u00edpicas de uma bancada de testes de resist\u00eancia el\u00e9trica para MCB incluem um banco de carga LR program\u00e1vel, acionamento servoacionado, monitoramento em tempo real dos contatos e desligamento autom\u00e1tico de seguran\u00e7a.<\/p>\n<div class=\"bl-pdp-feature-grid\">\n<div class=\"bl-pdp-feature-card\">\n                <strong>IEC 60898\u20111 Cl\u00e1usula 9.11<\/strong><br \/>\n                Totalmente em conformidade com os requisitos de teste de resist\u00eancia el\u00e9trica para disjuntores miniatura (MCBs).\n            <\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Banco de carga L-R program\u00e1vel<\/strong><br \/>\n                Fator de pot\u00eancia ajust\u00e1vel (0,85 \u00b10,05). Suporta testes de corrente nominal e sobrecorrente.\n            <\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Monitoramento de contatos em tempo real<\/strong><br \/>\n                Mede a queda de tens\u00e3o, a dura\u00e7\u00e3o do arco e a resist\u00eancia de contato por ciclo.\n            <\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Desligamento autom\u00e1tico em caso de falha<\/strong><br \/>\n                Detecta falhas na soldagem por contato ou no disparo; interrompe o teste e registra o ciclo de falha.\n            <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery\">\n<h2>Caracter\u00edsticas da m\u00e1quina e processo de teste<\/h2>\n<div class=\"bl-pdp-gallery-grid\">\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Intelligence-Visibility.webp\" alt=\"Intelligence Visibility - real-time monitoring\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Intelig\u00eancia e Visibilidade<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Efficiency-Sustainability.webp\" alt=\"Efficiency Sustainability - energy saving\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Efici\u00eancia e Sustentabilidade<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Design-Integration.webp\" alt=\"Design Integration - modular engineering\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Design e integra\u00e7\u00e3o<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Safety-Reliability.webp\" alt=\"Safety Reliability - rigorous testing\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Seguran\u00e7a e confiabilidade<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<h2>Especifica\u00e7\u00f5es t\u00e9cnicas<\/h2>\n<div class=\"bl-pdp-summary\">Bancada de teste de resist\u00eancia el\u00e9trica em conformidade com a norma IEC 60898-1, cl\u00e1usula 9.11. Carga L-R program\u00e1vel, monitoramento de contato em tempo real, desligamento de seguran\u00e7a autom\u00e1tico.<\/div>\n<div class=\"bl-pdp-table-wrap\">\n        Program\u00e1vel at\u00e9 <span style=\"color:#ff0000;\">20.000 ciclos<\/span> (Padr\u00e3o IEC: 4.000 ou 10.000)<\/p>\n<table class=\"bl-pdp-table\">\n<tbody>\n<tr>\n<th style=\"width: 35%;\">Normas aplic\u00e1veis<\/th>\n<td>IEC 60898\u20111 (Cl\u00e1usula 9.11), IEC 60947\u20112<\/td>\n<\/tr>\n<tr>\n<th>Escopo do teste<\/th>\n<td>Resist\u00eancia el\u00e9trica (ligar\/desligar) sob corrente nominal (I\u2099) e tens\u00e3o (U\u2099)<\/td>\n<\/tr>\n<tr>\n<th>Tipo de banco de carga<\/th>\n<td>Indutivo-resistivo (L-R), program\u00e1vel. Fator de pot\u00eancia ajust\u00e1vel de 0,7 a 1,0 (padr\u00e3o 0,85 \u00b10,05).<\/td>\n<\/tr>\n<tr>\n<th>Faixa de tens\u00e3o<\/th>\n<td>At\u00e9 440V CA (monof\u00e1sico ou trif\u00e1sico, configur\u00e1vel)<\/td>\n<\/tr>\n<tr>\n<th>Faixa atual<\/th>\n<td>6A \u2013 125A (program\u00e1vel, conforme a classifica\u00e7\u00e3o do disjuntor)<\/td>\n<\/tr>\n<tr>\n<th>Ciclos de teste (resist\u00eancia)<\/th>\n<\/tr>\n<tr>\n<th>Sistema de atua\u00e7\u00e3o<\/th>\n<td>Servomotorizado, velocidade de 6 a 30 opera\u00e7\u00f5es\/minuto (ajust\u00e1vel), curso program\u00e1vel.<\/td>\n<\/tr>\n<tr>\n<th>Par\u00e2metros de monitoramento<\/th>\n<td>Queda de tens\u00e3o no contato (mV), dura\u00e7\u00e3o do arco (ms), temperatura do contato (\u00b0C), contagem de ciclos<\/td>\n<\/tr>\n<tr>\n<th>Detec\u00e7\u00e3o de falhas<\/th>\n<td>Detec\u00e7\u00e3o de contato soldado, falha no disparo, temperatura excessiva \u2013 desligamento autom\u00e1tico + alarme<\/td>\n<\/tr>\n<tr>\n<th>Controle e registro de dados<\/th>\n<td>PLC (Siemens) + IHM, m\u00f3dulo DAQ, Ethernet\/OPC UA, exporta\u00e7\u00e3o CSV ou SQL<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<h2>Principais vantagens t\u00e9cnicas<\/h2>\n<div class=\"bl-pdp-grid\">\n<div class=\"bl-pdp-card\">\n<h4>Simula\u00e7\u00e3o de arco no mundo real<\/h4>\n<p>            O banco de carga L-R reproduz um fator de pot\u00eancia realista (0,85) e condi\u00e7\u00f5es de corrente de partida, essenciais para verificar o desempenho de eros\u00e3o por contato e extin\u00e7\u00e3o do arco.\n        <\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>An\u00e1lise de contato por ciclo<\/h4>\n<p>            O sistema de aquisi\u00e7\u00e3o de dados de alta velocidade captura a queda de tens\u00e3o e a dura\u00e7\u00e3o do arco em cada opera\u00e7\u00e3o. Os dados de tend\u00eancia identificam a degrada\u00e7\u00e3o gradual do contato antes da falha.\n        <\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Desligamento autom\u00e1tico de seguran\u00e7a<\/h4>\n<p>            Se os contatos soldarem ou o disjuntor n\u00e3o desarmar, o sistema corta imediatamente a energia, interrompe a atua\u00e7\u00e3o e registra o ciclo de falha, protegendo tanto o equipamento quanto a amostra de teste.\n        <\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Relat\u00f3rios prontos para certifica\u00e7\u00e3o<\/h4>\n<p>            Todos os resultados dos testes (formas de onda, registros de temperatura, contagens de ciclos) s\u00e3o armazenados em um banco de dados inviol\u00e1vel, gerando relat\u00f3rios prontos para auditoria para os organismos de certifica\u00e7\u00e3o IEC\/UL.\n        <\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-partners\">\n        <span class=\"bl-pdp-partners-title\">Aprovado pelos l\u00edderes do setor<\/span><\/p>\n<div class=\"bl-pdp-partners-list\">\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738413289.webp\" alt=\"ABB\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594739263598.webp\" alt=\"DELIXI\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594739675877.webp\" alt=\"EKF\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738101609.webp\" alt=\"CHAC\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738124777.webp\" alt=\"Schneider\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738797907.webp\" alt=\"IEK GROUP\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738411369.webp\" alt=\"Bevone\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738389707.webp\" alt=\"Weg\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738361034.webp\" alt=\"HUYU\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738416677.webp\" alt=\"RAAD\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738314557.webp\" alt=\"WALTONE\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738445639.webp\" alt=\"HAVELLS\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-case\">\n<h3>Hist\u00f3ria de sucesso do cliente<\/h3>\n<p>Para realizar os testes de resist\u00eancia el\u00e9trica da norma IEC 60898-1, cl\u00e1usula 9.11, em 30 disjuntores miniatura (MCBs) diferentes (variando de 6A a 63A), um laborat\u00f3rio de certifica\u00e7\u00e3o internacional utilizou nosso equipamento de teste de resist\u00eancia el\u00e9trica para MCBs, o que permitiu que os testes fossem conclu\u00eddos em 12 semanas \u2013 uma economia de tempo de 50% em rela\u00e7\u00e3o \u00e0 configura\u00e7\u00e3o anterior.<\/p>\n<p>O monitoramento automatizado de contato e a detec\u00e7\u00e3o de falhas por ciclo permitiram que eles determinassem que havia um problema com o material de contato em um de seus prot\u00f3tipos, possibilitando a corre\u00e7\u00e3o do problema antes da produ\u00e7\u00e3o.<\/p>\n<div class=\"bl-pdp-case-stats\">\n<div class=\"bl-pdp-case-stat\"><strong>12 semanas<\/strong> Campanha de teste completa<\/div>\n<div class=\"bl-pdp-case-stat\"><strong>30 modelos<\/strong> Tipos de MCB verificados<\/div>\n<div class=\"bl-pdp-case-stat\"><strong>100%<\/strong> Rastreabilidade por ciclo de teste<\/div>\n<\/p><\/div>\n<p style=\"margin-top: 12px; font-size: 14px;\">A bancada no laborat\u00f3rio agora est\u00e1 sendo usada para todos os testes regulares de resist\u00eancia el\u00e9trica e esse m\u00e9todo de teste foi acreditado como estando em conformidade com a norma ISO 17025.<\/p>\n<\/p><\/div>\n<h2>Aplica\u00e7\u00f5es e Ambientes de Teste<\/h2>\n<div class=\"bl-pdp-feature\">\n<div class=\"bl-pdp-feature-list\">\n<div class=\"bl-pdp-feature-item\"><strong>Laborat\u00f3rios de certifica\u00e7\u00e3o IEC\/UL<\/strong> \u2013 Testes de tipo para aprova\u00e7\u00e3o do produto<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Garantia de qualidade na fabrica\u00e7\u00e3o de MCB<\/strong> \u2013 Amostragem em lote e verifica\u00e7\u00e3o de rotina<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Valida\u00e7\u00e3o de P&amp;D<\/strong> \u2013 Compare os materiais de contato, os designs da c\u00e2mara de arco e os mecanismos de mola.<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Qualifica\u00e7\u00e3o de fornecedores<\/strong> \u2013 Verifica\u00e7\u00e3o de entrada de mecanismos MCB de terceiros<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<h2>Entrega e comissionamento padr\u00e3o<\/h2>\n<div class=\"bl-pdp-steps\">\n<div class=\"bl-pdp-step\"><strong>1. Revis\u00e3o do projeto<\/strong> 10 a 15 dias \u00b7 Layout 3D e esquemas el\u00e9tricos<\/div>\n<div class=\"bl-pdp-step\"><strong>2. Fabrica\u00e7\u00e3o<\/strong> 45-60 dias<\/div>\n<div class=\"bl-pdp-step\"><strong>3. Pr\u00e9-GORDURA<\/strong> Na f\u00e1brica de Benlong, com testemunhas clientes.<\/div>\n<div class=\"bl-pdp-step\"><strong>4. Instala\u00e7\u00e3o<\/strong> No local em 5 a 7 dias<\/div>\n<div class=\"bl-pdp-step\"><strong>5. Treinamento e fase de adapta\u00e7\u00e3o<\/strong> Treinamento para operadores e manuten\u00e7\u00e3o<\/div>\n<div class=\"bl-pdp-step\"><strong>6. SAT final<\/strong> 7 a 10 dias \u00b7 relat\u00f3rio de aceita\u00e7\u00e3o<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-cta\">\n<h2>Solicite um or\u00e7amento personalizado para bancada de testes de resist\u00eancia el\u00e9trica.<\/h2>\n<p>Por favor, envie-nos as especifica\u00e7\u00f5es do MCB (correntes nominais, ciclo de teste, fatores de pot\u00eancia) e o volume de teste pretendido. Nossos engenheiros podem fornecer uma solu\u00e7\u00e3o em conformidade com a norma IEC 60898-1, cl\u00e1usula 9.11.<\/p>\n<p>        <a class=\"bl-pdp-btn\" href=\"\/pt\/contact\/\">Consulte agora<\/a><\/p>\n<p class=\"bl-pdp-footnote\">WhatsApp: +86 150 5837 0007 | E-mail: xsb@benlongkj.cn | Suporte em ingl\u00eas e chin\u00eas<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-two-col\">\n<div class=\"bl-pdp-col-main\">\n<h3>Por que escolher a Benlong para testes de resist\u00eancia el\u00e9trica?<\/h3>\n<ul>\n<li>Mais de 15 anos de experi\u00eancia em design. <strong>bancadas de teste de resist\u00eancia el\u00e9trica MCB<\/strong> para laborat\u00f3rios e f\u00e1bricas<\/li>\n<li>Tecnologia comprovada de banco de carga L-R com controle preciso do fator de pot\u00eancia.<\/li>\n<li>Monitoramento de contato em tempo real (queda de tens\u00e3o, dura\u00e7\u00e3o do arco, temperatura)<\/li>\n<li>Desligamento autom\u00e1tico \u00e0 prova de falhas \u2013 protege equipamentos e amostras.<\/li>\n<li>Registro de dados pronto para auditoria \u2013 exporta\u00e7\u00e3o em SQL, OPC UA ou CSV<\/li>\n<\/ul><\/div>\n<div class=\"bl-pdp-col-side\">\n<h3>O sistema padr\u00e3o inclui<\/h3>\n<p>Mecanismo de abertura e fechamento servoacionado<br \/>\nBanco de carga LR program\u00e1vel (inclui ajuste do fator de pot\u00eancia)<br \/>\nPLC de alta velocidade (Siemens) + m\u00f3dulo de aquisi\u00e7\u00e3o de dados<br \/>\nTela sens\u00edvel ao toque HMI<br \/>\nSensores de medi\u00e7\u00e3o de queda de tens\u00e3o por contato<br \/>\nMonitoramento de temperatura (termopares)<br \/>\nCabine de seguran\u00e7a com parada de emerg\u00eancia<br \/>\n1 conjunto de disjuntores (1P\/2P\/3P\/4P)<br \/>\nCertifica\u00e7\u00e3o de Calibra\u00e7\u00e3o<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-internal-links\">\n        <span class=\"bl-pdp-internal-links-title\">Solu\u00e7\u00f5es relacionadas<\/span><\/p>\n<div class=\"bl-pdp-links-list\">\n            <a href=\"https:\/\/benlongkj.com\/pt\/mcb-mechanism-life-test-bench-product\/\">Bancada de Teste de Vida \u00datil do Mecanismo MCB<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/pt\/mcb-automatic-testing-line\/\">Linha de teste autom\u00e1tico MCB<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/pt\/mcb-long-time-thermal-calibration-bench-product\/\">Bancada de Calibra\u00e7\u00e3o T\u00e9rmica de Longo Prazo MCB<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/pt\/mcb-semi-automatic-thermal-trip-calibration-bench-type-a-product\/\">Bancada de Calibra\u00e7\u00e3o de Disparo T\u00e9rmico do MCB<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/pt\/iot-smart-mcb-automatic-production-line-product\/\">Linha de produ\u00e7\u00e3o de MCBs inteligentes para IoT<\/a>\n        <\/div>\n<\/p><\/div>\n<h2>Perguntas frequentes<\/h2>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Qual a diferen\u00e7a entre testes de vida mec\u00e2nica e testes de vida el\u00e9trica para disjuntores?<\/div>\n<p>O teste das caracter\u00edsticas mec\u00e2nicas dos disjuntores testa o mecanismo sem a aplica\u00e7\u00e3o de corrente el\u00e9trica, utilizando ciclos mec\u00e2nicos \u2013 isso apenas verifica se a durabilidade mec\u00e2nica da alavanca e da mola suporta esses ciclos. O teste de resist\u00eancia el\u00e9trica, na corrente e tens\u00e3o nominais especificadas para cada ciclo, submete os contatos a arcos el\u00e9tricos\/eros\u00e3o e estresse t\u00e9rmico. Nosso teste de resist\u00eancia el\u00e9trica exemplifica o atendimento a esse requisito de conformidade com a norma IEC 60898-1, cl\u00e1usula 9.11.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Qual o fator de pot\u00eancia necess\u00e1rio para os testes de resist\u00eancia el\u00e9trica da IEC?<\/div>\n<p>De acordo com a cl\u00e1usula 9.11 da norma IEC 60898-1, as cargas indutivas devem ter um fator de pot\u00eancia entre 0,85 e 0,90. Em nossas instala\u00e7\u00f5es, dispomos de uma carga de resist\u00eancia indutiva vari\u00e1vel (LR) que pode ser configurada para 0,85 ou outro valor, conforme solicitado.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">O banco de ensaio para automaticamente se os contatos soldarem?<\/div>\n<p>As tens\u00f5es de contato e a continuidade do circuito s\u00e3o monitoradas pelo sistema de teste de corrente. Se houver uma falha na abertura (soldagem) ou no disparo, o teste \u00e9 interrompido, um alarme \u00e9 ativado e o ciclo de falha \u00e9 registrado.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Quantos ciclos de teste o banco de testes pode realizar continuamente?<\/div>\n<p>A bancada foi projetada para operar 24 horas por dia, 7 dias por semana. O ciclo de teste padr\u00e3o (resist\u00eancia) \u00e9 de 20.000 ciclos (a Comiss\u00e3o Eletrot\u00e9cnica Internacional \u2013 IEC exige 4.000 ou 10.000 ciclos, dependendo do tipo de disjuntor). O sistema registrar\u00e1 todos os dados automaticamente e tamb\u00e9m poder\u00e1 pausar ou continuar quando necess\u00e1rio.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">\u00c9 poss\u00edvel testar disjuntores tripolares simultaneamente em bancada?<\/div>\n<p>Sim. A bancada \u00e9 capaz de suportar disjuntores miniatura (MCBs) com configura\u00e7\u00f5es de 1P, 2P, 3P e 4P, permitindo que disjuntores multipolares tenham o mecanismo de atua\u00e7\u00e3o configurado para acionar todos os polos de forma s\u00edncrona e fornecer monitoramento separado para cada polo.<\/p>\n<\/p><\/div>\n<div style=\"margin: 32px 0 16px; font-size: 12px; text-align: center; border-top: 1px solid #e9edf2; padding-top: 16px; color: #5f7d9c;\">\n        Todas as especifica\u00e7\u00f5es est\u00e3o sujeitas a acordo t\u00e9cnico final. Benlong Automation \u2013 Solu\u00e7\u00f5es de teste de resist\u00eancia el\u00e9trica em conformidade com a norma IEC 60898-1, cl\u00e1usula 9.11, desde 2010.\n    <\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Bancada de teste de resist\u00eancia el\u00e9trica para disjuntores Benlong, em conformidade com a norma IEC 60898-1, cl\u00e1usula 9.11. Carga L-R program\u00e1vel (FP 0,85), monitoramento em tempo real da queda de tens\u00e3o nos contatos e do arco el\u00e9trico, desligamento autom\u00e1tico em caso de soldagem dos contatos. Para laborat\u00f3rios de certifica\u00e7\u00e3o e controle de qualidade na fabrica\u00e7\u00e3o de disjuntores.<\/p>","protected":false},"featured_media":136,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[20],"product_tag":[],"class_list":["post-137","product","type-product","status-publish","has-post-thumbnail","product_cat-test-bench-project","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/benlongkj.com\/pt\/wp-json\/wp\/v2\/product\/137","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/benlongkj.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/benlongkj.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/pt\/wp-json\/wp\/v2\/comments?post=137"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/pt\/wp-json\/wp\/v2\/media\/136"}],"wp:attachment":[{"href":"https:\/\/benlongkj.com\/pt\/wp-json\/wp\/v2\/media?parent=137"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/benlongkj.com\/pt\/wp-json\/wp\/v2\/product_brand?post=137"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/benlongkj.com\/pt\/wp-json\/wp\/v2\/product_cat?post=137"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/benlongkj.com\/pt\/wp-json\/wp\/v2\/product_tag?post=137"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}