1. Equipment input voltage: 380V ± 10%, 50Hz; ± 1Hz;
2. Equipment automation types: “Semi automatic equipment” and “Fully automatic equipment”.
3. Equipment production rhythm: 3-15 seconds per unit, or customized according to customer production capacity.
4. Device compatibility: Within the same series of products, different specifications of 2-pole, 3-pole, and 4-pole can be switched with one click or scan code.
5. Laser marking parameters: automatic scanning switching parameters.
6. On/off detection: The number and time of detections can be set arbitrarily.
7. High voltage output range: 0-5000V; The leakage current is 10mA, 20mA, 100mA, and 200mA, which can be selected in different levels.
8. Detection of high-voltage insulation time: The parameters can be set arbitrarily from 1 to 999S.
9. High voltage detection part: When the product is in the open state, the voltage resistance between the detection phase and the bottom plate is tested; When the product is in an open state, detect the voltage resistance between the incoming and outgoing lines; When the product is in a closed state, detect the voltage resistance between phases.
10. Optional for testing when the product is in a horizontal state or when the product is in a vertical state.
11. The equipment has alarm display functions such as fault alarm and pressure monitoring.
12. There are two operating systems available: Chinese and English.
13. All core accessories are imported from different countries and regions such as Italy, Sweden, Germany, Japan, the United States, Taiwan, etc.
14. The device can be equipped with functions such as the “Smart Energy Analysis and Energy Conservation Management System” and the “Smart Equipment Service Big Data Cloud Platform”.
15. Having independent and independent intellectual property rights