{"id":87,"date":"2026-06-01T10:38:14","date_gmt":"2026-06-01T10:38:14","guid":{"rendered":"https:\/\/khkrh7q1ur.wpdns.site\/product\/mccb-long-time-thermal-calibration-bench\/"},"modified":"2026-06-09T03:50:01","modified_gmt":"2026-06-09T03:50:01","slug":"mccb-long-time-thermal-calibration-bench-product","status":"publish","type":"product","link":"https:\/\/benlongkj.com\/id\/mccb-long-time-thermal-calibration-bench-product\/","title":{"rendered":"Bangku kalibrasi termal jangka panjang MCCB"},"content":{"rendered":"<div class=\"bl-pdp-wrapper\">\n<div class=\"bl-pdp-split\">\n<div class=\"bl-pdp-split-text\">\n<div class=\"bl-pdp-badge\">Long\u2011time overload \u00b7 High\u2011stability current<\/div>\n<h1>High\u2011Stability MCCB Long\u2011Time Thermal Calibration Test Bench<\/h1>\n<p>Ini <strong>Bangku kalibrasi termal jangka panjang MCCB<\/strong> is an essential solution for verifying and adjusting the thermal trip characteristics of molded case circuit breakers. Designed for continuous, high\u2011current operation (up to 500A or higher per station), it accurately simulates real\u2011world overload conditions, allowing manufacturers to calibrate the breaker\u2019s trip curve for optimal overload protection. The system integrates high\u2011stability current sources (<span style=\"color:#d32f2f;\">drift <2% over 8 hours<\/span>), precise temperature monitoring, and automated data logging for full traceability.<\/p>\n<p>Key capabilities include programmable test currents (e.g., 100% In, 135% In), multiple independent test stations, and real\u2011time trip time measurement with \u00b10.1% accuracy. The bench supports MCCB frames from 100A to 800A (customizable up to 1600A) and 1P\u20114P configurations. An optional environmental chamber maintains consistent ambient temperature for even more repeatable results. All test results are automatically recorded and can be exported to MES for quality audits. Ideal for MCCB manufacturing QC, certification labs, and routine production sampling.<\/p>\n<p><span style=\"color: #2872fa; font-weight: 500;\">Standard delivery: 45-60 days | Current stability <2% drift | Multi\u2011station parallel testing<\/span><\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-split-media\">\n            <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/retouch_2025120810414826-1.png\" alt=\"MCCB long time thermal calibration bench\" \/><\/p>\n<div style=\"font-size: 11px; margin-top: 8px;\">Long\u2011time thermal calibration station (actual product)<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-definition\">\n<h2>What is an MCCB Long\u2011Time Thermal Calibration Bench?<\/h2>\n<p>Sebuah <strong>MCCB long\u2011time thermal calibration bench<\/strong> is a specialized test system used to verify and adjust the overload (thermal) trip characteristic of molded case circuit breakers. The thermal trip unit uses a bimetal strip that bends under prolonged overcurrent. This bench applies stable, programmable test currents (e.g., 100% of rated current to ensure no trip, then 135% to verify trip within the required time window) and measures trip time with high accuracy. Unlike simple go\/no\u2011go testers, it also allows operators to adjust the bimetal position via a screw mechanism, re\u2011test, and confirm correct calibration. The bench typically includes multiple independent test positions, a high\u2011stability constant current source, and data logging software. It is essential for IEC 60947\u20112 compliance (clause on overload protection) and is used in MCCB manufacturing plants, quality control labs, and certification bodies. As a <strong>non\u2011standard custom solution<\/strong>, we tailor the bench to your MCCB frame sizes, current ratings, and production volume.<\/p>\n<div class=\"bl-pdp-feature-grid\">\n<div class=\"bl-pdp-feature-card\">\n                <strong>High\u2011stability current source<\/strong><br \/>\n                Drift <2% over 8 hours, THD <3%, accuracy \u00b11% of reading.\n            <\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Multi\u2011station parallel testing<\/strong><br \/>\n                Test multiple MCCBs simultaneously (4\u201116 positions) for high throughput.\n            <\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Programmable test currents<\/strong><br \/>\n                100%, 135%, 150%, or custom values per IEC 60947\u20112.\n            <\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Automated data logging<\/strong><br \/>\n                Records trip time, test current, ambient temperature, and pass\/fail status.\n            <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery\">\n<h2>Key Features &#038; Calibration Process<\/h2>\n<div class=\"bl-pdp-gallery-grid\">\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Intelligence-Visibility.webp\" alt=\"Intelligence Visibility - real-time monitoring\" \/><\/p>\n<div class=\"bl-pdp-gallery-caption\">Intelijen &amp; Visibilitas<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Efficiency-Sustainability.webp\" alt=\"Efficiency Sustainability - energy saving\" \/><\/p>\n<div class=\"bl-pdp-gallery-caption\">Efisiensi &amp; Keberlanjutan<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Design-Integration.webp\" alt=\"Design Integration - modular engineering\" \/><\/p>\n<div class=\"bl-pdp-gallery-caption\">Desain &amp; Integrasi<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Safety-Reliability.webp\" alt=\"Safety Reliability - rigorous testing\" \/><\/p>\n<div class=\"bl-pdp-gallery-caption\">Keamanan &amp; Keandalan<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<h2>Spesifikasi Teknis<\/h2>\n<div class=\"bl-pdp-summary\">High\u2011stability thermal calibration bench for MCCB overload testing. Multiple test positions, programmable current, automated data logging. Customizable for various frame sizes.<\/div>\n<div class=\"bl-pdp-table-wrap\">\n<table class=\"bl-pdp-table\">\n<tbody>\n<tr>\n<th style=\"width: 35%;\">Supported MCCB frames<\/th>\n<td>100A \u2013 800A (standard); custom up to 1600A<\/span> &#8212;<br \/>\n                <\/tr>\n<tr>\n<th>Jumlah stasiun pengujian<\/th>\n<td>4, 8, 12, or 16 independent positions (customizable)<\/span>&#8212;<br \/>\n                <\/tr>\n<tr>\n<th>Test current range<\/th>\n<td>Up to 500A per station (expandable)<\/span>&#8212;<br \/>\n                <\/tr>\n<tr>\n<th>Akurasi saat ini<\/th>\n<td>\u00b11% of reading, stability <2% drift over 8 hours<\/span>&#8212;<br \/>\n                <\/tr>\n<tr>\n<th>Timing resolution<\/th>\n<td>0.01s (standard), accuracy \u00b10.1% of reading<\/span>&#8212;<br \/>\n                <\/tr>\n<tr>\n<th>Jenis tes<\/th>\n<td>No\u2011trip at 100% In, trip at 135% In (or 150% In by IEC 60947\u20112)<\/span>&#8212;<br \/>\n                <\/tr>\n<tr>\n<th>Data logging<\/th>\n<td>Trip time, test current, ambient temperature, pass\/fail per station<\/span>&#8212;<br \/>\n                <\/tr>\n<tr>\n<th>Cooling system<\/th>\n<td>Forced air cooling between tests to ensure repeatability<\/span>&#8212;<br \/>\n                <\/tr>\n<tr>\n<th>Sistem kontrol<\/th>\n<td>PLC (Siemens\/Mitsubishi) dengan HMI, penyimpanan resep untuk 20+ jenis produk.<\/span>&#8212;<br \/>\n                <\/tr>\n<tr>\n<th>Catu daya<\/th>\n<td>380V \u00b110% 50Hz | Three\u2011phase, heavy\u2011duty<\/span>&#8212;<br \/>\n                <\/tr>\n<\/tbody>\n<\/table><\/div>\n<h2>Keunggulan Teknis Inti<\/h2>\n<div class=\"bl-pdp-grid\">\n<div class=\"bl-pdp-card\">\n<h4>Exceptionally stable current over long tests<\/h4>\n<p>            The bench\u2019s closed\u2011loop current control (IGBT or thyristor) maintains set current within \u00b12% even after 8 hours of continuous operation \u2013 critical for long\u2011time tests that can last 1\u20118 hours. Waveform distortion below 3% ensures accurate bimetal heating.\n        <\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Parallel testing maximizes throughput<\/h4>\n<p>            With 8 independent stations, you can calibrate 8 MCCBs simultaneously. Each station has its own current source, timer, and pass\/fail indication. Bottlenecks are eliminated, and per\u2011unit test time is drastically reduced.\n        <\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Automatic trip detection &#038; adjustment assistance<\/h4>\n<p>            Sensors detect the exact moment the breaker trips. The HMI displays trip time and compares it to the acceptable window. For adjustable breakers, we can integrate a stepper motor to automatically turn the calibration screw \u2013 forming a fully automatic calibration loop.\n        <\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Temperature compensation for consistent results<\/h4>\n<p>            Ambient temperature affects bimetal trip time. The bench monitors temperature and can automatically adjust acceptance windows or test currents to compensate. An optional environmental chamber maintains 25\u00b0C \u00b13\u00b0C for lab\u2011grade tests.\n        <\/p><\/div>\n<\/p><\/div>\n<p>    <!-- \u5408\u4f5c\u4f19\u4f34\u6a21\u5757 --><\/p>\n<div class=\"bl-pdp-partners\">\n        <span class=\"bl-pdp-partners-title\">Dipercaya oleh para pemimpin industri.<\/span><\/p>\n<div class=\"bl-pdp-partners-list\">\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738413289.webp\" alt=\"ABB\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594739263598.webp\" alt=\"DELIXI\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594739675877.webp\" alt=\"EKF\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594741141751.webp\" alt=\"KRIPAL\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738593989.webp\" alt=\"HPL\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738101609.webp\" alt=\"CHAC\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738124777.webp\" alt=\"Schneider\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738797907.webp\" alt=\"IEK GROUP\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738812289.webp\" alt=\"SUNIR\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738411369.webp\" alt=\"Bevone\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738389707.webp\" alt=\"Weg\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738361034.webp\" alt=\"HUYU\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738416677.webp\" alt=\"RAAD\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738314557.webp\" alt=\"WALTONE\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738445639.webp\" alt=\"HAVELLS\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738720809.webp\" alt=\"C&amp;S electric\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-case\">\n<h3>Customer Success Story \u2013 MCCB Manufacturer<\/h3>\n<p>A Brazilian MCCB manufacturer was experiencing inconsistent long\u2011time trip results due to unstable test currents. Their old bench had current drift >5% over 1 hour, causing false failures and rework. Benlong replaced it with an 8\u2011station long\u2011time thermal calibration bench featuring closed\u2011loop current control (<1% drift over 8 hours). Results after 3 months:<\/p>\n<div class=\"bl-pdp-case-stats\">\n<div class=\"bl-pdp-case-stat\"><strong>Hasil tahap pertama<\/strong> 98% (up from 85%)<\/div>\n<div class=\"bl-pdp-case-stat\"><strong>+200%<\/strong> Throughput (parallel 8 stations)<\/div>\n<div class=\"bl-pdp-case-stat\"><strong>70%<\/strong> Reduction in operator time<\/div>\n<\/p><\/div>\n<p style=\"margin-top: 12px; font-size: 14px;\">The bench paid for itself in 8 months and helped the customer pass an IEC audit with complete traceability records.<\/p>\n<\/p><\/div>\n<h2>Aplikasi dan Integrasi<\/h2>\n<div class=\"bl-pdp-feature\">\n<div class=\"bl-pdp-feature-list\">\n<div class=\"bl-pdp-feature-item\"><strong>Kontrol kualitas manufaktur MCCB<\/strong> \u2013 Routine long\u2011time calibration on production lines<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Type test laboratories<\/strong> \u2013 Certification testing per IEC 60947\u20112<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Inspeksi masuk<\/strong> \u2013 Verifying purchased MCCBs meet trip curves<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>R&#038;D validation<\/strong> \u2013 Characterizing new bimetal designs<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<h2>Custom Engineering &#038; Delivery<\/h2>\n<div class=\"bl-pdp-steps\">\n<div class=\"bl-pdp-step\"><strong>1. Analisis kebutuhan<\/strong> 10-20 days \u00b7 MCCB samples, test current specs<\/div>\n<div class=\"bl-pdp-step\"><strong>2. Current source &#038; station design<\/strong> 15-30 days \u00b7 number of stations, cooling system<\/div>\n<div class=\"bl-pdp-step\"><strong>3. Manufaktur<\/strong> 45-60 hari<\/div>\n<div class=\"bl-pdp-step\"><strong>4. Pre\u2011FAT<\/strong> Di pabrik Benlong<\/div>\n<div class=\"bl-pdp-step\"><strong>5. Installation &#038; training<\/strong> On-site 5\u20117 days<\/div>\n<div class=\"bl-pdp-step\"><strong>6. SAT Akhir<\/strong> 5\u20117 days \u00b7 acceptance report<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-cta\">\n<h2>Request a Custom MCCB Long\u2011Time Calibration Bench Quote<\/h2>\n<p>Send us your MCCB specifications (frame sizes, rated currents, test volume). Our engineers will design a bench with the optimal number of stations, current range, and data logging features \u2013 including a full ROI analysis.<\/p>\n<p>        <a class=\"bl-pdp-btn\" href=\"\/id\/contact\/\">Ajukan Pertanyaan Sekarang<\/a><\/p>\n<p class=\"bl-pdp-footnote\">WhatsApp: +86 150 5837 0007 | Email: xsb@benlongkj.cn | English &#038; Chinese support<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-two-col\">\n<div class=\"bl-pdp-col-main\">\n<h3>Why Choose Benlong for MCCB Calibration Benches?<\/h3>\n<ul>\n<li>15+ tahun mendesain <strong>thermal calibration equipment<\/strong> untuk produsen MCCB<\/li>\n<li>Proven high\u2011stability current sources (drift <2% over 8 hours)<\/li>\n<li>Multi\u2011station parallel testing (4\u201116 positions)<\/li>\n<li>Integrated temperature monitoring and optional environmental chamber<\/li>\n<li>Full data logging with MES connectivity (OPC UA \/ Modbus)<\/li>\n<\/ul><\/div>\n<div class=\"bl-pdp-col-side\">\n<h3>Bangku Kustom Khas Meliputi:<\/h3>\n<p>High\u2011stability constant current source \u00b7 Multi\u2011station test rack (custom positions) \u00b7 Programmable current controller \u00b7 Digital timers (\u00b10.1%) \u00b7 HMI touch screen \u00b7 Ambient temperature sensor \u00b7 Data logging software (CSV \/ SQL) \u00b7 Forced cooling fans \u00b7 Safety interlocks \u00b7 Calibration certificate \u00b7 1\u2011year warranty<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<p>    <!-- \u5185\u90e8\u94fe\u63a5 --><\/p>\n<div class=\"bl-pdp-internal-links\">\n        <span class=\"bl-pdp-internal-links-title\">Solusi terkait<\/span><\/p>\n<div class=\"bl-pdp-links-list\">\n            <a href=\"https:\/\/benlongkj.com\/id\/mccb-semi-automatic-high-voltage-test-bench-product\/\">Bangku Uji Tegangan Tinggi Semi-Otomatis MCCB<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/id\/mccb-manual-thermal-calibration-bench-product\/\">Bangku Kalibrasi Termal Manual MCCB<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/id\/mccb-tripping-mechanism-machine-product\/\">Mesin Uji Mekanisme Pemutus MCCB<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/id\/mcb-long-time-thermal-calibration-bench-product\/\">Bangku Kalibrasi Termal Jangka Panjang MCB<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/id\/mccb-automatic-production-line-product\/\">Jalur Produksi Otomatis MCCB<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/id\/mcb-automatic-testing-line\/\">Jalur Pengujian Otomatis MCB<\/a>\n        <\/div>\n<\/p><\/div>\n<h2>Pertanyaan yang Sering Diajukan<\/h2>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">What is the difference between long\u2011time thermal calibration and instantaneous magnetic testing?<\/div>\n<p>Long\u2011time thermal testing applies moderate overload currents (e.g., 135% In) for seconds to hours to verify the bimetal\u2019s thermal trip characteristic. Instantaneous magnetic testing applies high currents (5\u201110\u00d7 In) for milliseconds to verify short\u2011circuit protection. This bench is dedicated to long\u2011time thermal tests only.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">How many MCCBs can be tested at once?<\/div>\n<p>Standard configurations support 4, 8, 12, or 16 independent stations. Each station has its own current source and timer, allowing parallel testing of multiple breakers with different ratings.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">How is current stability ensured over long tests (e.g., 8 hours)?<\/div>\n<p>The bench uses a closed\u2011loop current control system with a high\u2011accuracy current transformer and thyristor or IGBT regulator. It compensates for line voltage fluctuations and temperature drift, maintaining set current within \u00b12% over 8 hours.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Can the bench automatically adjust the bimetal screw?<\/div>\n<p>Yes. For MCCBs with an external adjustment screw, we can integrate a stepper motor or electric screwdriver on each station. The system will test, adjust, and re\u2011test until the trip time falls within the acceptance window \u2013 fully automatic calibration.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">What is the typical test duration for a 100A MCCB?<\/div>\n<p>At 100% In, the test runs for 1 hour (no trip expected). At 135% In, trip time is typically between 45\u201155 seconds for a 100A frame. The bench can be programmed to run these sequences automatically.<\/p>\n<\/p><\/div>\n<div style=\"margin: 32px 0 16px; font-size: 12px; text-align: center; border-top: 1px solid #e9edf2; padding-top: 16px; color: #5f7d9c;\">\n        All specifications subject to final technical agreement. Benlong Automation \u2013 IEC 60947\u20112 compliant MCCB calibration solutions since 2008.\n    <\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Bangku kalibrasi termal jangka panjang MCCB khusus untuk pengujian beban berlebih sesuai IEC 60947\u20112. Arus stabilitas tinggi (<2% drift), 4\u201116 independent stations, programmable 100% \/ 135% In, automated data logging. Optional auto\u2011adjustment. Ideal for MCCB production QC and type testing.\n<\/p>","protected":false},"featured_media":86,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[20],"product_tag":[],"class_list":["post-87","product","type-product","status-publish","has-post-thumbnail","product_cat-test-bench-project","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/benlongkj.com\/id\/wp-json\/wp\/v2\/product\/87","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/benlongkj.com\/id\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/benlongkj.com\/id\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/id\/wp-json\/wp\/v2\/comments?post=87"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/id\/wp-json\/wp\/v2\/media\/86"}],"wp:attachment":[{"href":"https:\/\/benlongkj.com\/id\/wp-json\/wp\/v2\/media?parent=87"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/benlongkj.com\/id\/wp-json\/wp\/v2\/product_brand?post=87"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/benlongkj.com\/id\/wp-json\/wp\/v2\/product_cat?post=87"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/benlongkj.com\/id\/wp-json\/wp\/v2\/product_tag?post=87"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}