{"id":31,"date":"2026-06-01T10:37:38","date_gmt":"2026-06-01T10:37:38","guid":{"rendered":"https:\/\/khkrh7q1ur.wpdns.site\/product\/rcbo-semi-automatic-comprehensive-test-bench\/"},"modified":"2026-06-10T07:10:16","modified_gmt":"2026-06-10T07:10:16","slug":"rcbo-semi-automatic-comprehensive-test-bench-product","status":"publish","type":"product","link":"https:\/\/benlongkj.com\/fr\/rcbo-semi-automatic-comprehensive-test-bench-product\/","title":{"rendered":"Banc d&#039;essai complet semi-automatique RCBO"},"content":{"rendered":"<div class=\"bl-pdp-wrapper\">\n<div class=\"bl-pdp-split\">\n<div class=\"bl-pdp-split-text\">\n<div class=\"bl-pdp-badge\">10\u201163A \u00b7 Type AC\/A \u00b7 10\u2011500mA<\/div>\n<h1>Banc d\u2019essai complet semi-automatique RCBO<\/h1>\n<p>Le test semi-automatique de toutes les fonctions effectu\u00e9es sur les disjoncteurs diff\u00e9rentiels avec protection contre les surintensit\u00e9s (RCBO) sera r\u00e9alis\u00e9 \u00e0 l\u2019aide de cet \u00e9quipement. Les trois principaux tests effectu\u00e9s par ce banc sont : le test de d\u00e9clenchement diff\u00e9rentiel (\u00e9galement appel\u00e9 test de fuite), le test de v\u00e9rification du bouton de test et le test de mesure du temps de d\u00e9clenchement. Le mode de fonctionnement semi-automatique permet le chargement et le d\u00e9chargement manuels des RCBO ainsi que le test automatis\u00e9, ainsi que le processus automatis\u00e9 de validation ou d\u2019\u00e9chec \u00e0 l\u2019aide des indicateurs OK ou NG. Il r\u00e9pondra \u00e0 tous vos besoins, y compris le dispositif pour accueillir des RCBO de taille modulaire 18 mm, configuration 1P+N, configuration 3P+N et une plage de courant nominal de 10A \u00e0 63A (10A, 16A, 20A, 25A, 32A, 40A, 50A et 63A). De plus, les dispositifs vous permettront de passer facilement et rapidement d\u2019un mod\u00e8le de RCBO \u00e0 un autre sans changer d\u2019outils.<\/p>\n<p><span style=\"color: #2872fa; font-weight: 500;\">Livraison standard : 30-45 jours | Changement rapide de mod\u00e8le | Commutation \u00e0 une touche type AC\/A<\/span><\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-split-media\">\n            <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/RCBO-semi-automatic-comprehensive-test-bench.webp\" alt=\"Banc d&#039;essai complet semi-automatique RCBO\"><\/p>\n<div style=\"font-size: 11px; margin-top: 8px;\">Testeur de fuite et bouton de test RCBO (produit r\u00e9el)<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-definition\">\n<h2>Quels probl\u00e8mes ce banc d'essai permet-il de r\u00e9soudre ?<\/h2>\n<p>En g\u00e9n\u00e9ral, plusieurs testeurs sont n\u00e9cessaires pour tester les RCBO \u00e0 diff\u00e9rentes intensit\u00e9s nominales (de 10A \u00e0 63A), sensibilit\u00e9s de fuite (30mA, 100mA, etc.) et avec des configurations de test s\u00e9par\u00e9es pour les appareils de type AC et A. Le changement entre diff\u00e9rents mod\u00e8les de test peut prendre beaucoup de temps, et des erreurs sont susceptibles de se produire dans l\u2019interpr\u00e9tation manuelle des r\u00e9sultats de r\u00e9ussite\/\u00e9chec. Le banc d\u2019essai complet semi-automatique vise \u00e0 r\u00e9soudre ces probl\u00e8mes cl\u00e9s en :<\/p>\n<ul>\n<li><strong>Large compatibilit\u00e9<\/strong> \u2013 Offre des options pour supporter plusieurs intensit\u00e9s nominales (jusqu\u2019\u00e0 8) et configurations (1P+N ou 3P+N) dans un seul dispositif au lieu d\u2019exiger des prises factices\/appareils de test s\u00e9par\u00e9s pour chaque configuration.<\/li>\n<li><strong>Changement rapide de mod\u00e8le<\/strong> \u2013 Le dispositif modulaire 18 mm permet de passer d\u2019un RCBO \u00e0 un autre en quelques secondes, pas en minutes.<\/li>\n<li><strong>Commutation \u00e0 une touche type AC\/A<\/strong> Aucune reconfiguration mat\u00e9rielle n\u00e9cessaire gr\u00e2ce \u00e0 la commutation automatique des formes d\u2019onde de test et des angles de phase par l\u2019instrument.<\/li>\n<li><strong>Jugement automatique r\u00e9ussite\/\u00e9chec<\/strong> \u2013 Les indicateurs OK\/NG et l\u2019affichage num\u00e9rique \u00e9liminent les erreurs d\u2019interpr\u00e9tation de l\u2019op\u00e9rateur.<\/li>\n<\/ul>\n<div class=\"bl-pdp-feature-grid\">\n<div class=\"bl-pdp-feature-card\">\n                <strong>8 intensit\u00e9s nominales, un seul dispositif<\/strong><\/p>\n<p>Supporte 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A \u2013 aucun changement d\u2019outillage n\u00e9cessaire entre les intensit\u00e9s.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Commutation \u00e0 une touche type AC &amp; A<\/strong><\/p>\n<p>Testez les RCBO de type A \u00e0 0\u00b0, 90\u00b0, 135\u00b0, 180\u00b0, -90\u00b0, -135\u00b0 d\u2019angles de phase avec un seul bouton.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Courant de fuite r\u00e9glable 10\u2011500mA<\/strong><\/p>\n<p>I\u0394n programmable couvre les standards 30mA, 100mA, 300mA et valeurs personnalis\u00e9es.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Jugement automatique OK\/NG<\/strong><\/p>\n<p>Voyants vert\/rouge + affichage num\u00e9rique du temps de d\u00e9clenchement \u2013 r\u00e9sultats instantan\u00e9s et sans ambigu\u00eft\u00e9.<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery\">\n<h2>Capacit\u00e9s de test et avantages pour les clients<\/h2>\n<div class=\"bl-pdp-gallery-grid\">\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Intelligence-Visibility.webp\" alt=\"Visibilit\u00e9 des renseignements - surveillance en temps r\u00e9el\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Intelligence &amp; Visibilit\u00e9 \u2013 affichage en temps r\u00e9el du temps de d\u00e9clenchement et du courant de fuite<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Efficiency-Sustainability.webp\" alt=\"Durabilit\u00e9 et efficacit\u00e9 \u00e9nerg\u00e9tique - \u00e9conomies d&#039;\u00e9nergie\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Efficacit\u00e9 &amp; Durabilit\u00e9 \u2013 un banc remplace plusieurs testeurs d\u00e9di\u00e9s, r\u00e9duisant la consommation d\u2019\u00e9nergie et l\u2019espace au sol<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Design-Integration.webp\" alt=\"Int\u00e9gration de la conception - ing\u00e9nierie modulaire\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Conception &amp; Int\u00e9gration \u2013 dispositif modulaire 18 mm pour un changement rapide de mod\u00e8le<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Safety-Reliability.webp\" alt=\"Fiabilit\u00e9 et s\u00e9curit\u00e9 - tests rigoureux\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">S\u00e9curit\u00e9 &amp; Fiabilit\u00e9 \u2013 zone de test ferm\u00e9e, arr\u00eat d\u2019urgence et indication OK\/NG<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<h2>Sp\u00e9cifications techniques<\/h2>\n<div class=\"bl-pdp-summary\">Banc d\u2019essai semi-automatique RCBO. Courant de fuite 10\u2011500mA, temps de d\u00e9clenchement 1\u20119999ms, commutation \u00e0 une touche AC &amp; type A, 1P+N\/3P+N, 10A\u201163A, tension AC 1\u2011400V.<\/div>\n<div class=\"bl-pdp-table-wrap\">\n<table class=\"bl-pdp-table\">\n<tbody>\n<tr>\n<th style=\"width: 35%;\">Types de RCBO compatibles<\/th>\n<td>1P+N, 3P+N ; 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A ; taille modulaire 18mm \u2013\n                <\/td>\n<\/tr>\n<tr>\n                <\/tr>\n<tr>\n<th>Plage de courant de fuite<\/th>\n<td>AC 10\u2011500mA (programmable, par ex., 30mA, 100mA, 300mA)\n                <\/td>\n<\/tr>\n<tr>\n<th>Pr\u00e9cision du courant de fuite<\/th>\n<td>Erreur relative \u22641,5%, d\u00e9rive &lt;2% pendant le test, THD \u22643%\n                <\/td>\n<\/tr>\n<tr>\n<th>Plage de mesure du temps de d\u00e9clenchement<\/th>\n<td>1 \u2013 9999ms, affichage \u00e9lectronique\n                <\/td>\n<\/tr>\n<tr>\n<th>Temps de stabilisation du courant<\/th>\n<td>\u22642 secondes (de l\u2019application au courant stable)\n                <\/td>\n<\/tr>\n<tr>\n<th>Tension de test<\/th>\n<td>AC 1\u2011400V (r\u00e9glable)\n                <\/td>\n<\/tr>\n<tr>\n<th>Test du bouton de test<\/th>\n<td>Pression automatique du cylindre + v\u00e9rification du d\u00e9clenchement\n                <\/td>\n<\/tr>\n<tr>\n<th>Test de l\u2019angle de phase type A<\/th>\n<td>0\u00b0, 90\u00b0, 135\u00b0, 180\u00b0, -90\u00b0, -135\u00b0 (commutation \u00e0 une touche)\n                <\/td>\n<\/tr>\n<tr>\n<th>Sortie du r\u00e9sultat<\/th>\n<td>Voyants indicateurs OK\/NG (vert\/rouge) + affichage num\u00e9rique du temps\n                <\/td>\n<\/tr>\n<tr>\n<th>Alimentation \u00e9lectrique<\/th>\n<td>380V \u00b110% 50Hz\n                <\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<h2>Avantages cl\u00e9s pour le client \u2013 Pourquoi les fabricants choisissent ce banc<\/h2>\n<div class=\"bl-pdp-grid\">\n<div class=\"bl-pdp-card\">\n<h4>Avantage 1 : Un banc pour 8 intensit\u00e9s de courant<\/h4>\n<p>Ce banc d\u2019essai utilise un seul dispositif pour tester toutes les valeurs d\u2019amp\u00e9rage ci-dessus au lieu d\u2019acheter des testeurs individuels pour chaque intensit\u00e9 de 10, 16, 20, 25, 32, 40, 50 et 63 Amp\u00e8res. Le passage d\u2019une intensit\u00e9 \u00e0 une autre se fait en quelques secondes ; s\u00e9lectionnez votre recette HMI requise puis chargez le RCBO. Cela a permis de r\u00e9duire jusqu\u2019\u00e0 60% les d\u00e9penses d\u2019investissement et d\u2019\u00e9conomiser de l\u2019espace au sol dans l\u2019usine.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Avantage 2 : Test AC &amp; type A sans modification mat\u00e9rielle<\/h4>\n<p>Un test traditionnel d\u2019un RCBO de type A n\u00e9cessite un r\u00e9glage complexe des angles de phase lors du test. Notre syst\u00e8me de commutation unique peut produire les formes d\u2019onde de test n\u00e9cessaires (0\u00b0, 90\u00b0, 135\u00b0, 180\u00b0, -90\u00b0, et -135\u00b0) en utilisant un seul bouton sur le devant du testeur. Ainsi, il n\u2019est pas n\u00e9cessaire d\u2019utiliser des d\u00e9phaseurs externes ni des r\u00e9glages manuels, ce qui permet de gagner 50% du temps consacr\u00e9 au test d\u2019un produit de type A.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Avantage 3 : Courant de fuite rapide et pr\u00e9cis<\/h4>\n<p>La source de courant se stabilise en moins de 2 secondes avec une d\u00e9rive &lt;2% et une distorsion de forme d\u2019onde &lt;3% \u2013 r\u00e9pondant aux exigences IEC 61008\u20111 \/ 61009\u20111 pour une mesure r\u00e9p\u00e9table du temps de d\u00e9clenchement. Les op\u00e9rateurs n\u2019attendent plus la stabilisation du courant, augmentant ainsi le d\u00e9bit.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Avantage 4 : V\u00e9rification automatique du bouton de test<\/h4>\n<p>Le bouton de test du RCBO est test\u00e9 par pression et le d\u00e9clenchement confirm\u00e9 par l\u2019utilisation d\u2019un cylindre pneumatique au lieu d\u2019une pression manuelle, ce qui peut prendre plus de temps et \u00eatre incoh\u00e9rent selon les op\u00e9rateurs. Le cycle de test se d\u00e9roule en m\u00eame temps que le cycle de test de fuite.<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-partners\">\n        <span class=\"bl-pdp-partners-title\">Reconnue par les leaders du secteur<\/span><\/p>\n<div class=\"bl-pdp-partners-list\">\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738413289.webp\" alt=\"ABB\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594739263598.webp\" alt=\"D\u00c9LICI\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594739675877.webp\" alt=\"EKF\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594741141751.webp\" alt=\"KRIPAL\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738593989.webp\" alt=\"HPL\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738101609.webp\" alt=\"CHAC\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738124777.webp\" alt=\"Schneider\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738797907.webp\" alt=\"Groupe IEK\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738812289.webp\" alt=\"SUNIR\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738411369.webp\" alt=\"Bevone\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738389707.webp\" alt=\"Weg\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738361034.webp\" alt=\"HUYU\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738416677.webp\" alt=\"RAAD\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738314557.webp\" alt=\"WALTONE\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738445639.webp\" alt=\"HAVELLS\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738720809.webp\" alt=\"C&amp;S \u00e9lectrique\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-case\">\n<h3>Succ\u00e8s client \u2013 Le fabricant de RCBO r\u00e9duit le temps de test de 70%<\/h3>\n<p>Auparavant, ils devaient utiliser deux testeurs diff\u00e9rents, un pour chaque type d\u2019appareil, et changer manuellement les dispositifs pour diff\u00e9rentes intensit\u00e9s de courant. Le temps moyen de test \u00e9tait de 45 secondes par unit\u00e9, et les tests d\u2019angle de phase de type A n\u00e9cessitaient un testeur externe. Apr\u00e8s avoir utilis\u00e9 leur nouveau banc d\u2019essai semi-automatique complet avec une touche pour basculer entre AC et type A et le dispositif modulaire 18mm, ils ont pu atteindre :<\/p>\n<div class=\"bl-pdp-case-stats\">\n<div class=\"bl-pdp-case-stat\"><strong>14 sec\/unit\u00e9<\/strong> Temps moyen de test (contre 45 sec)<\/div>\n<div class=\"bl-pdp-case-stat\"><strong>8 intensit\u00e9s<\/strong> Couvertes sur un seul banc (rempla\u00e7ant 4 testeurs)<\/div>\n<div class=\"bl-pdp-case-stat\"><strong>0%<\/strong> Erreur op\u00e9rateur dans le jugement r\u00e9ussite\/\u00e9chec (voyants OK\/NG)<\/div>\n<\/p><\/div>\n<p style=\"margin-top: 12px; font-size: 14px;\">Ce produit a permis au client d'augmenter la production gr\u00e2ce \u00e0 l'expansion, ce qui a entra\u00een\u00e9 une r\u00e9duction des co\u00fbts g\u00e9n\u00e9raux. Ils ont pu amortir le co\u00fbt de cet \u00e9quipement en sept mois.<\/p>\n<\/p><\/div>\n<h2>Applications \u2013 Les domaines dans lesquels ce banc apporte le plus de valeur ajout\u00e9e<\/h2>\n<div class=\"bl-pdp-feature\">\n<div class=\"bl-pdp-feature-list\">\n<div class=\"bl-pdp-feature-item\"><strong>Lignes de production RCBO<\/strong> \u2013 Test fonctionnel final (fuite, bouton de test, temps de d\u00e9clenchement)<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>laboratoires de contr\u00f4le de la qualit\u00e9<\/strong> \u2013 \u00c9chantillonnage par lot et tests de certification<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Inspection \u00e0 r\u00e9ception<\/strong> \u2013 V\u00e9rification des RCBO achet\u00e9s aupr\u00e8s de plusieurs fournisseurs<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Validation de la R&amp;D<\/strong> \u2013 Caract\u00e9risation des nouveaux mod\u00e8les de RCBO (type AC et A)<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<h2>Ing\u00e9nierie et livraison sur mesure<\/h2>\n<div class=\"bl-pdp-steps\">\n<div class=\"bl-pdp-step\"><strong>1. Analyse d&#039;\u00e9chantillons RCBO<\/strong> 7-15 jours \u00b7 intensit\u00e9s nominales, type (AC\/A), normes de test<\/div>\n<div class=\"bl-pdp-step\"><strong>Installation et configuration des param\u00e8tres<\/strong> 10-20 jours \u00b7 dispositif modulaire 18 mm, plages de courant de fuite<\/div>\n<div class=\"bl-pdp-step\"><strong>3. Fabrication et assemblage<\/strong> 30 \u00e0 45 jours<\/div>\n<div class=\"bl-pdp-step\"><strong>4. Pr\u00e9-FAT<\/strong> \u00c0 l&#039;usine de Benlong<\/div>\n<div class=\"bl-pdp-step\"><strong>5. Installation et formation<\/strong> Sur place, 2 \u00e0 3 jours<\/div>\n<div class=\"bl-pdp-step\"><strong>6. SAT final<\/strong> 2 \u00e0 3 jours \u00b7 rapport de r\u00e9ception<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-cta\">\n<h2>Demandez un devis personnalis\u00e9 pour un banc de test RCBO<\/h2>\n<p>Nous souhaitons recevoir les \u00e9l\u00e9ments suivants : \u00e9chantillons de RCBO, mod\u00e8les avec intensit\u00e9 nominale, sp\u00e9cifications de test (AC ou type), de votre part. Sur la base des donn\u00e9es fournies ainsi que des sp\u00e9cifications techniques, nos ing\u00e9nieurs concevront un banc de test semi-automatique avec des capacit\u00e9s d'\u00e9change rapide, un commutateur AC\/A \u00e0 une touche, ainsi qu'une analyse compl\u00e8te du retour sur investissement (ROI).<\/p>\n<p>        <a class=\"bl-pdp-btn\" href=\"\/fr\/contact\/\">Renseignez-vous d\u00e8s maintenant<\/a><\/p>\n<p class=\"bl-pdp-footnote\">WhatsApp\u00a0: +86\u00a0150\u00a05837\u00a00007 | Courriel\u00a0: xsb@benlongkj.cn | Assistance en anglais et en chinois<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-two-col\">\n<div class=\"bl-pdp-col-main\">\n<h3>Pourquoi choisir Benlong pour les bancs de test RCBO ?<\/h3>\n<ul>\n<li>Plus de 15 ans d&#039;exp\u00e9rience en conception <strong>\u00e9quipement de test RCBO<\/strong> pour les fabricants de dispositifs \u00e0 courant r\u00e9siduel<\/li>\n<li>Dispositif modulaire 18 mm \u00e9prouv\u00e9 \u2013 supporte 8 intensit\u00e9s nominales sans changement d'outillage<\/li>\n<li>Commutation \u00e0 une touche AC &amp; type A (angles de phase 0\u00b0, 90\u00b0, 135\u00b0, 180\u00b0, -90\u00b0, -135\u00b0)<\/li>\n<li>Courant de fuite programmable 10\u2011500mA, temps de d\u00e9clenchement 1\u20119999ms, pr\u00e9cision \u00b11.5%<\/li>\n<li>V\u00e9rification automatique du bouton de test et jugement OK\/NG<\/li>\n<\/ul><\/div>\n<div class=\"bl-pdp-col-side\">\n<h3>Le banc standard comprend<\/h3>\n<p>Dispositif de test modulaire, 18 mm, type 1P + N\/3P + N source de courant de fuite programmable, 10mA \u00e0 500mA module de commutation AC\/A minuterie num\u00e9rique d\u00e9clenchement 1 ms \u00e0 9999 ms actionneur bouton-poussoir \u2013 v\u00e9rin pneumatique voyants indicateurs OK\/NG PLC \u2013 IHM Enceinte de s\u00e9curit\u00e9 Manuel utilisateur Certificat d'\u00e9talonnage Garantie 1 an<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-internal-links\">\n        <span class=\"bl-pdp-internal-links-title\">Solutions connexes<\/span><\/p>\n<div class=\"bl-pdp-links-list\">\n            <a href=\"https:\/\/benlongkj.com\/fr\/rcbo-automatic-magnetic-reset-testing-machine-product\/\">Machine automatique de r\u00e9armement magn\u00e9tique et de test RCBO<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/fr\/rcbo-pcba-automatic-soldering-machine-product\/\">Machine \u00e0 souder automatique RCBO PCBA<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/fr\/mcb-automatic-testing-line\/\">Ligne de test automatique MCB<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/fr\/load-isolation-switch-automatic-testing-line-product\/\">Ligne de test du commutateur d&#039;isolement de charge<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/fr\/mccb-semi-automatic-high-voltage-test-bench-product\/\">Banc d&#039;essai haute tension semi-automatique pour MCCB<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/fr\/ac-contactor-comprehensive-test-machine-product\/\">Machine d&#039;essai compl\u00e8te pour contacteurs CA<\/a>\n        <\/div>\n<\/p><\/div>\n<h2>Foire aux questions<\/h2>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Quels types de RCBO ce banc peut-il tester ?<\/div>\n<p>1 p\u00f4le avec neutre et 3 p\u00f4les avec neutre (taille modulaire 18 mm) intensit\u00e9s nominales 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A RCBO. L'appareil est capable de tester \u00e0 la fois les dispositifs de type AC et A, \u00e0 l'exception des dispositifs de type AC dont les angles de phase sont r\u00e9gl\u00e9s par une seule touche.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Comment changer entre les diff\u00e9rentes intensit\u00e9s nominales ?<\/div>\n<p>Le dispositif modulaire 18 mm accepte toutes les intensit\u00e9s sans n\u00e9cessiter de modifications m\u00e9caniques. Vous s\u00e9lectionnez la recette de test souhait\u00e9e (par exemple, 16A, 32A) depuis l'\u00e9cran tactile IHM, et le banc r\u00e8gle automatiquement le seuil de courant de fuite et la fen\u00eatre de temps de d\u00e9clenchement appropri\u00e9s. Aucun changement d'outillage n'est n\u00e9cessaire.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Quelle est la diff\u00e9rence entre les tests de type AC et A ?<\/div>\n<p>Les RCBO de type AC sont con\u00e7us pour d\u00e9clencher avec un courant r\u00e9siduel sinuso\u00efdal, tandis que les RCBO de type A doivent \u00e9galement d\u00e9clencher pour diff\u00e9rents types de commutation, tels que le d\u00e9calage de phase avec diff\u00e9rents degr\u00e9s d'angle de phase (par exemple 0 degr\u00e9s, 90 degr\u00e9s et 135 degr\u00e9s). Le syst\u00e8me du banc dispose d'un syst\u00e8me de commutation \u00e0 une touche pour g\u00e9n\u00e9rer la forme d'onde requise pour les tests de type A, mais aucun d\u00e9phaseur externe n'est n\u00e9cessaire pour l'utilisation avec ces dispositifs.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Le banc appuie-t-il automatiquement sur le bouton de test ?<\/div>\n<p>Certainement. Un v\u00e9rin pneumatique appuiera automatiquement sur le bouton d\u2019un test RCBO et v\u00e9rifiera qu\u2019il d\u00e9clenche dans le temps requis. Cela \u00e9limine la n\u00e9cessit\u00e9 d\u2019appuyer manuellement sur le bouton de test et garantit la coh\u00e9rence des r\u00e9sultats de test.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Quel est le temps de cycle de test typique\u00a0?<\/div>\n<p>Le temps de cycle approximatif pour un test de fuite de 30 mA, qui inclut la v\u00e9rification du bouton de test, est d\u2019environ 10-15 secondes pour chaque RCBO ; cependant, il peut prendre plus de temps pour effectuer des tests de type A (\u00e0 plusieurs angles de phase) ; n\u00e9anmoins, toutes les v\u00e9rifications ou tests de type A restent consid\u00e9rablement plus rapides que la v\u00e9rification manuelle.<\/p>\n<\/p><\/div>\n<div style=\"margin: 32px 0 16px; font-size: 12px; text-align: center; border-top: 1px solid #e9edf2; padding-top: 16px; color: #5f7d9c;\">\n        Toutes les sp\u00e9cifications sont sujettes \u00e0 un accord technique final. Benlong Automation \u2013 Solutions compl\u00e8tes de test RCBO pour les fabricants de dispositifs \u00e0 courant r\u00e9siduel.\n    <\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Banc d&#039;essai semi-automatique complet pour disjoncteurs diff\u00e9rentiels (RCBO)\u00a0: contr\u00f4le du courant de fuite (10-500\u00a0mA), du temps de d\u00e9clenchement (1-9999\u00a0ms) et v\u00e9rification du bouton de test. Compatible avec les configurations 1P+N\/3P+N, 10-63\u00a0A, et les commutations de type\u00a0A et AC (angles de phase de 0 \u00e0 180\u00b0). Montage modulaire de 18\u00a0mm\u00a0: aucun changement d&#039;outillage n\u00e9cessaire pour diff\u00e9rentes valeurs nominales. Diagnostic automatique OK\/NG. Id\u00e9al pour le contr\u00f4le qualit\u00e9 en production et l&#039;inspection \u00e0 r\u00e9ception des disjoncteurs diff\u00e9rentiels.<\/p>","protected":false},"featured_media":30,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[20],"product_tag":[],"class_list":["post-31","product","type-product","status-publish","has-post-thumbnail","product_cat-test-bench-project","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/benlongkj.com\/fr\/wp-json\/wp\/v2\/product\/31","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/benlongkj.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/benlongkj.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/fr\/wp-json\/wp\/v2\/comments?post=31"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/fr\/wp-json\/wp\/v2\/media\/30"}],"wp:attachment":[{"href":"https:\/\/benlongkj.com\/fr\/wp-json\/wp\/v2\/media?parent=31"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/benlongkj.com\/fr\/wp-json\/wp\/v2\/product_brand?post=31"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/benlongkj.com\/fr\/wp-json\/wp\/v2\/product_cat?post=31"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/benlongkj.com\/fr\/wp-json\/wp\/v2\/product_tag?post=31"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}