{"id":137,"date":"2026-06-01T10:38:55","date_gmt":"2026-06-01T10:38:55","guid":{"rendered":"https:\/\/khkrh7q1ur.wpdns.site\/product\/mcb-electrical-endurance-test-bench\/"},"modified":"2026-06-08T03:21:09","modified_gmt":"2026-06-08T03:21:09","slug":"mcb-electrical-endurance-test-bench-product","status":"publish","type":"product","link":"https:\/\/benlongkj.com\/fr\/mcb-electrical-endurance-test-bench-product\/","title":{"rendered":"Banc d&#039;essai d&#039;endurance \u00e9lectrique pour disjoncteurs miniatures (MCB)"},"content":{"rendered":"<div class=\"bl-pdp-wrapper\">\n<div class=\"bl-pdp-split\">\n<div class=\"bl-pdp-split-text\">\n<div class=\"bl-pdp-badge\">IEC 60898\u20111 Article 9.11 \u00b7 Endurance \u00e9lectrique<\/div>\n<h1>Banc d&#039;essai d&#039;endurance \u00e9lectrique pour disjoncteurs miniatures (MCB)<\/h1>\n<p>Le banc d&#039;essai d&#039;endurance \u00e9lectrique pour disjoncteurs miniatures (MCB) est un syst\u00e8me de test automatis\u00e9 sophistiqu\u00e9 con\u00e7u pour tester la dur\u00e9e de vie \u00e9lectrique et les caract\u00e9ristiques de commutation des disjoncteurs miniatures (MCB) dans leurs configurations de fonctionnement nominales, conform\u00e9ment aux normes IEC 60898-1 (article 9.11) et IEC 60947-2. Ce banc d&#039;essai mesure la capacit\u00e9 des MCB \u00e0 supporter des cycles r\u00e9p\u00e9t\u00e9s d&#039;\u00e9tablissement et de coupure du contact \u00e9lectrique sous une alimentation de courant nominal (I\u2099) et de tension nominale (U\u2099). Durant ces tests, les contacts des MCB ne doivent pr\u00e9senter ni soudure, ni arc \u00e9lectrique excessif, ni signes de d\u00e9faillance m\u00e9canique.<\/p>\n<p>Un syst\u00e8me d&#039;actionnement, pilot\u00e9 par servomoteur avec un contr\u00f4le pr\u00e9cis de la synchronisation et de la vitesse, est \u00e9quip\u00e9 d&#039;un banc de charge programmable inductif-r\u00e9sistif (cos \u03c6 = 0,85 \u00b1 0,05) \u00e0 facteur de puissance donn\u00e9 et d&#039;un automate programmable (PLC) interfac\u00e9 \u00e0 un syst\u00e8me d&#039;acquisition de donn\u00e9es (DAQ) d\u00e9di\u00e9. Ce dernier surveille la chute de tension de contact, la dur\u00e9e de l&#039;arc et l&#039;\u00e9l\u00e9vation de temp\u00e9rature \u00e0 chaque cycle. Un r\u00e9seau de capteurs automatis\u00e9s d\u00e9tecte les d\u00e9fauts de d\u00e9clenchement ou de soudage et d\u00e9clenche un arr\u00eat de s\u00e9curit\u00e9. Toutes les donn\u00e9es de test, incluant le nombre de cycles, les formes d&#039;onde du courant et les enregistrements de temp\u00e9rature, sont stock\u00e9es dans une base de donn\u00e9es s\u00e9curis\u00e9e sur le cloud, garantissant une tra\u00e7abilit\u00e9 et une conformit\u00e9 compl\u00e8tes.<\/p>\n<p><span style=\"color: #2872fa; font-weight: 500;\">D\u00e9lai de livraison standard\u00a0: 45 \u00e0 60\u00a0jours | Cycles de test jusqu\u2019\u00e0 20\u00a0000 | Conforme \u00e0 la norme IEC\u00a060898-1, paragraphe\u00a09.11<\/span><\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-split-media\">\n            <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/electrical-life-test-main-image-1.png\" alt=\"Banc d&#039;essai d&#039;endurance \u00e9lectrique pour disjoncteurs miniatures\"><\/p>\n<div style=\"font-size: 11px; margin-top: 8px;\">Banc d&#039;essai de dur\u00e9e de vie \u00e9lectrique avec banc de charge L-R (produit r\u00e9el)<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-definition\">\n<h2>Qu&#039;est-ce qu&#039;un banc d&#039;essai d&#039;endurance \u00e9lectrique pour disjoncteur miniature (MCB)\u00a0?<\/h2>\n<p>L&#039;objectif d&#039;un banc d&#039;essai d&#039;endurance \u00e9lectrique pour disjoncteur miniature (MCB) est de quantifier sa dur\u00e9e de vie apr\u00e8s de nombreux cycles de commutation. Contrairement aux essais m\u00e9caniques, o\u00f9 le disjoncteur fonctionne \u00e0 vide, les essais d&#039;endurance \u00e9lectrique fonctionnent en charge, en appliquant le courant et la tension nominaux \u00e0 chaque cycle d&#039;ouverture et de fermeture. Ce type d&#039;essai reproduit les conditions r\u00e9elles d&#039;utilisation, caract\u00e9ris\u00e9es par la formation d&#039;arcs \u00e9lectriques, l&#039;\u00e9rosion des contacts et des contraintes thermiques. R\u00e9alis\u00e9 pour les essais de type, l&#039;assurance qualit\u00e9 et la certification selon les normes IEC 60898-1 (article 9.11) et IEC 60947-2, cet appareil est un \u00e9l\u00e9ment essentiel du d\u00e9veloppement et de la certification d&#039;un MCB. Un banc d&#039;essai d&#039;endurance \u00e9lectrique pour MCB comprend g\u00e9n\u00e9ralement un banc de charge LR programmable, un actionnement servo-command\u00e9, une surveillance en temps r\u00e9el des contacts et un syst\u00e8me de coupure automatique de s\u00e9curit\u00e9.<\/p>\n<div class=\"bl-pdp-feature-grid\">\n<div class=\"bl-pdp-feature-card\">\n                <strong>IEC 60898\u20111 Article 9.11<\/strong><br \/>\n                Enti\u00e8rement conforme aux exigences des tests d&#039;endurance \u00e9lectrique pour les disjoncteurs miniatures.\n            <\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Banque de charge programmable L-R<\/strong><br \/>\n                Facteur de puissance ajustable (0,85 \u00b10,05). Prend en charge les tests de courant nominal et de surintensit\u00e9.\n            <\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Surveillance des contacts en temps r\u00e9el<\/strong><br \/>\n                Mesure la chute de tension, la dur\u00e9e de l&#039;arc et la r\u00e9sistance de contact par cycle.\n            <\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Arr\u00eat automatique en cas de panne<\/strong><br \/>\n                D\u00e9tecte la soudure par contact ou une d\u00e9faillance de d\u00e9clenchement ; arr\u00eate le test et enregistre le cycle de d\u00e9faut.\n            <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery\">\n<h2>Caract\u00e9ristiques de la machine et processus de test<\/h2>\n<div class=\"bl-pdp-gallery-grid\">\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Intelligence-Visibility.webp\" alt=\"Visibilit\u00e9 des renseignements - surveillance en temps r\u00e9el\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Renseignements et visibilit\u00e9<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Efficiency-Sustainability.webp\" alt=\"Durabilit\u00e9 et efficacit\u00e9 \u00e9nerg\u00e9tique - \u00e9conomies d&#039;\u00e9nergie\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Efficacit\u00e9 et durabilit\u00e9<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Design-Integration.webp\" alt=\"Int\u00e9gration de la conception - ing\u00e9nierie modulaire\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Conception et int\u00e9gration<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Safety-Reliability.webp\" alt=\"Fiabilit\u00e9 et s\u00e9curit\u00e9 - tests rigoureux\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">S\u00e9curit\u00e9 et fiabilit\u00e9<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<h2>Sp\u00e9cifications techniques<\/h2>\n<div class=\"bl-pdp-summary\">Banc d&#039;essai d&#039;endurance \u00e9lectrique conforme \u00e0 la norme IEC 60898\u20111, clause 9.11. Charge L-R programmable, surveillance des contacts en temps r\u00e9el, arr\u00eat de s\u00e9curit\u00e9 automatis\u00e9.<\/div>\n<div class=\"bl-pdp-table-wrap\">\n        Programmable jusqu&#039;\u00e0 <span style=\"color:#ff0000;\">20 000 cycles<\/span> (Valeur par d\u00e9faut CEI\u00a0: 4\u00a0000 ou 10\u00a0000)<\/p>\n<table class=\"bl-pdp-table\">\n<tbody>\n<tr>\n<th style=\"width: 35%;\">Normes applicables<\/th>\n<td>CEI 60898\u20111 (article 9.11), CEI 60947\u20112<\/td>\n<\/tr>\n<tr>\n<th>port\u00e9e de test<\/th>\n<td>Endurance \u00e9lectrique (commutation) sous courant nominal (I\u2099) et tension (U\u2099)<\/td>\n<\/tr>\n<tr>\n<th>type de banc de charge<\/th>\n<td>Inductif-r\u00e9sistif (G-D), programmable. Facteur de puissance r\u00e9glable de 0,7 \u00e0 1,0 (par d\u00e9faut\u00a0: 0,85 \u00b1 0,05).<\/td>\n<\/tr>\n<tr>\n<th>Plage de tension<\/th>\n<td>Jusqu&#039;\u00e0 440 V CA (monophas\u00e9 ou triphas\u00e9, configurable)<\/td>\n<\/tr>\n<tr>\n<th>Gamme actuelle<\/th>\n<td>6A \u2013 125A (programmable, selon le calibre du disjoncteur)<\/td>\n<\/tr>\n<tr>\n<th>cycles de test (endurance)<\/th>\n<\/tr>\n<tr>\n<th>Syst\u00e8me d&#039;actionnement<\/th>\n<td>Servomoteur, vitesse de 6 \u00e0 30 op\u00e9rations\/minute (r\u00e9glable), course programmable<\/td>\n<\/tr>\n<tr>\n<th>Param\u00e8tres de surveillance<\/th>\n<td>Chute de tension aux contacts (mV), dur\u00e9e de l&#039;arc (ms), temp\u00e9rature des contacts (\u00b0C), nombre de cycles<\/td>\n<\/tr>\n<tr>\n<th>D\u00e9tection des d\u00e9faillances<\/th>\n<td>D\u00e9tection de contact soud\u00e9, d\u00e9faut de d\u00e9clenchement, temp\u00e9rature excessive \u2013 arr\u00eat automatique et alarme<\/td>\n<\/tr>\n<tr>\n<th>Contr\u00f4le et enregistrement des donn\u00e9es<\/th>\n<td>Automate programmable (Siemens) + IHM, module d&#039;acquisition de donn\u00e9es, Ethernet\/OPC UA, exportation CSV ou SQL<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<h2>Principaux avantages techniques<\/h2>\n<div class=\"bl-pdp-grid\">\n<div class=\"bl-pdp-card\">\n<h4>Simulation d&#039;arcs dans le monde r\u00e9el<\/h4>\n<p>            Le banc de charge L\u2011R reproduit un facteur de puissance r\u00e9aliste (0,85) et des conditions d\u2019appel, essentiels pour v\u00e9rifier les performances d\u2019\u00e9rosion des contacts et d\u2019extinction de l\u2019arc.\n        <\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Analyse des contacts par cycle<\/h4>\n<p>            L&#039;acquisition de donn\u00e9es \u00e0 haute vitesse enregistre la chute de tension et la dur\u00e9e de l&#039;arc pour chaque op\u00e9ration. L&#039;analyse des tendances permet d&#039;identifier la d\u00e9gradation progressive des contacts avant la d\u00e9faillance.\n        <\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Arr\u00eat de s\u00e9curit\u00e9 automatique<\/h4>\n<p>            En cas de soudure des contacts ou de non-d\u00e9clenchement du disjoncteur, le syst\u00e8me coupe imm\u00e9diatement l&#039;alimentation, arr\u00eate l&#039;actionnement et enregistre le cycle de d\u00e9faillance, prot\u00e9geant ainsi \u00e0 la fois l&#039;\u00e9quipement et l&#039;\u00e9chantillon test\u00e9.\n        <\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Rapports pr\u00eats pour la certification<\/h4>\n<p>            Tous les r\u00e9sultats des tests (formes d&#039;onde, enregistrements de temp\u00e9rature, comptages de cycles) sont stock\u00e9s dans une base de donn\u00e9es inviolable, g\u00e9n\u00e9rant des rapports pr\u00eats pour l&#039;audit pour les organismes de certification IEC\/UL.\n        <\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-partners\">\n        <span class=\"bl-pdp-partners-title\">Reconnue par les leaders du secteur<\/span><\/p>\n<div class=\"bl-pdp-partners-list\">\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738413289.webp\" alt=\"ABB\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594739263598.webp\" alt=\"D\u00c9LICI\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594739675877.webp\" alt=\"EKF\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738101609.webp\" alt=\"CHAC\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738124777.webp\" alt=\"Schneider\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738797907.webp\" alt=\"Groupe IEK\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738411369.webp\" alt=\"Bevone\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738389707.webp\" alt=\"Weg\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738361034.webp\" alt=\"HUYU\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738416677.webp\" alt=\"RAAD\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738314557.webp\" alt=\"WALTONE\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738445639.webp\" alt=\"HAVELLS\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-case\">\n<h3>T\u00e9moignage client<\/h3>\n<p>Afin de r\u00e9aliser les tests d&#039;endurance \u00e9lectrique IEC 60898-1 Clause 9.11 pour 30 MCB diff\u00e9rents (allant de 6A \u00e0 63A), un laboratoire de certification international a utilis\u00e9 notre banc d&#039;essai d&#039;endurance \u00e9lectrique MCB, ce qui leur a permis de les terminer en 12 semaines \u2013 un gain de temps 50% par rapport \u00e0 leur configuration pr\u00e9c\u00e9dente.<\/p>\n<p>La surveillance automatis\u00e9e des contacts et la d\u00e9tection des d\u00e9faillances \u00e0 chaque cycle leur ont permis de d\u00e9terminer qu&#039;il y avait un probl\u00e8me de mat\u00e9riau de contact avec l&#039;un de leurs prototypes, ce qui leur a permis de corriger ce probl\u00e8me avant la production.<\/p>\n<div class=\"bl-pdp-case-stats\">\n<div class=\"bl-pdp-case-stat\"><strong>12 semaines<\/strong> Campagne de test compl\u00e8te<\/div>\n<div class=\"bl-pdp-case-stat\"><strong>30 mod\u00e8les<\/strong> Types de disjoncteurs v\u00e9rifi\u00e9s<\/div>\n<div class=\"bl-pdp-case-stat\"><strong>100%<\/strong> Tra\u00e7abilit\u00e9 par cycle de test<\/div>\n<\/p><\/div>\n<p style=\"margin-top: 12px; font-size: 14px;\">Le banc d&#039;essai du laboratoire est d\u00e9sormais utilis\u00e9 pour tous les tests r\u00e9guliers d&#039;endurance \u00e9lectrique et cette m\u00e9thode de test a \u00e9t\u00e9 accr\u00e9dit\u00e9e comme \u00e9tant conforme \u00e0 la norme ISO 17025.<\/p>\n<\/p><\/div>\n<h2>Applications et environnements de test<\/h2>\n<div class=\"bl-pdp-feature\">\n<div class=\"bl-pdp-feature-list\">\n<div class=\"bl-pdp-feature-item\"><strong>Laboratoires de certification IEC\/UL<\/strong> \u2013 Essais de type pour l\u2019homologation du produit<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Assurance qualit\u00e9 de la fabrication des disjoncteurs MCB<\/strong> \u2013 \u00c9chantillonnage par lots et v\u00e9rification de routine<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Validation de la R&amp;D<\/strong> \u2013 Comparer les mat\u00e9riaux de contact, les conceptions de la chambre \u00e0 arc et les m\u00e9canismes \u00e0 ressort<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Qualification des fournisseurs<\/strong> \u2013 V\u00e9rification \u00e0 r\u00e9ception des m\u00e9canismes MCB tiers<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<h2>Livraison et mise en service standard<\/h2>\n<div class=\"bl-pdp-steps\">\n<div class=\"bl-pdp-step\"><strong>1. Revue de conception<\/strong> 10 \u00e0 15 jours \u00b7 Conception 3D et sch\u00e9mas \u00e9lectriques<\/div>\n<div class=\"bl-pdp-step\"><strong>2. Fabrication<\/strong> 45 \u00e0 60 jours<\/div>\n<div class=\"bl-pdp-step\"><strong>3. Pr\u00e9-graisse<\/strong> \u00c0 l&#039;usine de Benlong, en pr\u00e9sence d&#039;un client<\/div>\n<div class=\"bl-pdp-step\"><strong>4. Installation<\/strong> Intervention sur site sous 5 \u00e0 7 jours<\/div>\n<div class=\"bl-pdp-step\"><strong>5. Formation et mont\u00e9e en puissance<\/strong> Formation des op\u00e9rateurs et de la maintenance<\/div>\n<div class=\"bl-pdp-step\"><strong>6. SAT final<\/strong> 7 \u00e0 10 jours \u00b7 rapport d&#039;acceptation<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-cta\">\n<h2>Demandez un devis personnalis\u00e9 pour un banc d&#039;essai d&#039;endurance \u00e9lectrique<\/h2>\n<p>Veuillez nous envoyer les sp\u00e9cifications du MCB (intensit\u00e9s nominales, cycle de test, facteurs de puissance) et le volume de test cible, nos ing\u00e9nieurs peuvent fournir une solution conforme \u00e0 la norme IEC 60898-1 pour la clause 9.11.<\/p>\n<p>        <a class=\"bl-pdp-btn\" href=\"\/fr\/contact\/\">Renseignez-vous d\u00e8s maintenant<\/a><\/p>\n<p class=\"bl-pdp-footnote\">WhatsApp\u00a0: +86\u00a0150\u00a05837\u00a00007 | Courriel\u00a0: xsb@benlongkj.cn | Assistance en anglais et en chinois<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-two-col\">\n<div class=\"bl-pdp-col-main\">\n<h3>Pourquoi choisir Benlong pour les essais d&#039;endurance \u00e9lectrique\u00a0?<\/h3>\n<ul>\n<li>Plus de 15 ans d&#039;exp\u00e9rience en conception <strong>Bancs d&#039;essai d&#039;endurance \u00e9lectrique MCB<\/strong> pour les laboratoires et les usines<\/li>\n<li>Technologie \u00e9prouv\u00e9e de banc de charge L-R avec contr\u00f4le pr\u00e9cis du facteur de puissance<\/li>\n<li>Surveillance des contacts en temps r\u00e9el (chute de tension, dur\u00e9e de l&#039;arc, temp\u00e9rature)<\/li>\n<li>Arr\u00eat automatique de s\u00e9curit\u00e9 \u2013 prot\u00e8ge l\u2019\u00e9quipement et les \u00e9chantillons<\/li>\n<li>Enregistrement des donn\u00e9es conforme aux exigences d&#039;audit \u2013 exportation SQL, OPC UA ou CSV<\/li>\n<\/ul><\/div>\n<div class=\"bl-pdp-col-side\">\n<h3>Le syst\u00e8me standard comprend<\/h3>\n<p>M\u00e9canisme de fermeture\/d\u00e9souverture servo-actionn\u00e9<br \/>\nBanc de charge programmable LR (avec r\u00e9glage du facteur de puissance)<br \/>\nAutomate programmable haute vitesse (Siemens) + module d&#039;acquisition de donn\u00e9es<br \/>\n\u00c9cran tactile IHM<br \/>\nCapteurs de mesure de chute de tension de contact<br \/>\nSurveillance de la temp\u00e9rature (thermocouples)<br \/>\nEnceinte de s\u00e9curit\u00e9 avec arr\u00eat d&#039;urgence<br \/>\n1 jeu de fixations MCB (1P\/2P\/3P\/4P)<br \/>\nCertification d&#039;\u00e9talonnage<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-internal-links\">\n        <span class=\"bl-pdp-internal-links-title\">Solutions connexes<\/span><\/p>\n<div class=\"bl-pdp-links-list\">\n            <a href=\"https:\/\/benlongkj.com\/fr\/mcb-mechanism-life-test-bench-product\/\">Banc d&#039;essai de dur\u00e9e de vie du m\u00e9canisme MCB<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/fr\/mcb-automatic-testing-line\/\">Ligne de test automatique MCB<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/fr\/mcb-long-time-thermal-calibration-bench-product\/\">Banc d&#039;\u00e9talonnage thermique longue dur\u00e9e MCB<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/fr\/mcb-semi-automatic-thermal-trip-calibration-bench-type-a-product\/\">Banc d&#039;\u00e9talonnage pour d\u00e9clenchement thermique de disjoncteur miniature<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/fr\/iot-smart-mcb-automatic-production-line-product\/\">Ligne de production de disjoncteurs intelligents IoT<\/a>\n        <\/div>\n<\/p><\/div>\n<h2>Foire aux questions<\/h2>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Quelle est la diff\u00e9rence entre les tests de dur\u00e9e de vie m\u00e9canique et les tests de dur\u00e9e de vie \u00e9lectrique des disjoncteurs miniatures ?<\/div>\n<p>Les essais de caract\u00e9ristiques m\u00e9caniques des disjoncteurs testent le m\u00e9canisme sans courant \u00e9lectrique par des cycles m\u00e9caniques. Ceci permet uniquement de v\u00e9rifier la r\u00e9sistance m\u00e9canique du levier et du ressort \u00e0 ces cycles. Les essais d&#039;endurance \u00e9lectrique, r\u00e9alis\u00e9s sous courant et tension nominaux sp\u00e9cifi\u00e9s pour chaque cycle, soumettent les contacts \u00e0 des contraintes d&#039;arc \u00e9lectrique\/d&#039;\u00e9rosion et thermiques. Nos essais d&#039;endurance \u00e9lectrique constituent un exemple de conformit\u00e9 \u00e0 la norme CEI 60898-1, paragraphe 9.11.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Quel facteur de puissance est requis pour les essais d&#039;endurance \u00e9lectrique CEI\u00a0?<\/div>\n<p>Les charges inductives doivent avoir un facteur de puissance compris entre 0,85 et 0,90 conform\u00e9ment \u00e0 la clause 9.11 de la norme IEC 60898-1. Nous disposons dans notre installation d&#039;une charge \u00e0 r\u00e9sistances inductives variables (LR) qui peut \u00eatre r\u00e9gl\u00e9e \u00e0 0,85 ou \u00e0 une autre valeur, sur demande.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Le banc s&#039;arr\u00eate-t-il automatiquement en cas de soudure des contacts\u00a0?<\/div>\n<p>Le syst\u00e8me de contr\u00f4le de courant surveille les tensions de contact et la continuit\u00e9 du circuit. En cas de d\u00e9faut d&#039;ouverture (soudure) ou de d\u00e9clenchement, le test s&#039;arr\u00eate, une alarme se d\u00e9clenche et un enregistrement du cycle de d\u00e9faillance est effectu\u00e9.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Combien de cycles de test le banc d&#039;essai peut-il effectuer en continu\u00a0?<\/div>\n<p>Le banc d&#039;essai a \u00e9t\u00e9 con\u00e7u pour fonctionner 24 h\/24 et 7 j\/7. Le cycle de test standard (endurance) est de 20\u00a0000 cycles (la Commission \u00e9lectrotechnique internationale \u2013 CEI exige 4\u00a0000 ou 10\u00a0000 cycles selon le type de disjoncteur). Le syst\u00e8me enregistre automatiquement toutes les donn\u00e9es et peut \u00eatre mis en pause ou repris \u00e0 la demande.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Le banc d&#039;essai peut-il tester simultan\u00e9ment des disjoncteurs tripolaires\u00a0?<\/div>\n<p>Oui. Le banc d&#039;essai peut supporter les disjoncteurs multipolaires (MCB) de configurations 1P, 2P, 3P et 4P, permettant ainsi de configurer le m\u00e9canisme d&#039;actionnement des MCB multipolaires pour actionner tous les p\u00f4les de mani\u00e8re synchrone et assurer une surveillance s\u00e9par\u00e9e pour chaque p\u00f4le.<\/p>\n<\/p><\/div>\n<div style=\"margin: 32px 0 16px; font-size: 12px; text-align: center; border-top: 1px solid #e9edf2; padding-top: 16px; color: #5f7d9c;\">\n        Toutes les sp\u00e9cifications sont soumises \u00e0 un accord technique final. Benlong Automation propose des solutions de test d&#039;endurance \u00e9lectrique conformes \u00e0 la norme IEC 60898\u20111, clause 9.11, depuis 2010.\n    <\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Banc d&#039;essai d&#039;endurance \u00e9lectrique pour disjoncteurs Benlong, conforme \u00e0 la norme CEI 60898-1, paragraphe 9.11. Charge L-R programmable (PF 0,85), surveillance en temps r\u00e9el de la chute de tension aux contacts et de l&#039;arc \u00e9lectrique, arr\u00eat automatique en cas de soudage des contacts. Destin\u00e9 aux laboratoires de certification et au contr\u00f4le qualit\u00e9 de la fabrication des disjoncteurs.<\/p>","protected":false},"featured_media":136,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[20],"product_tag":[],"class_list":["post-137","product","type-product","status-publish","has-post-thumbnail","product_cat-test-bench-project","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/benlongkj.com\/fr\/wp-json\/wp\/v2\/product\/137","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/benlongkj.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/benlongkj.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/fr\/wp-json\/wp\/v2\/comments?post=137"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/fr\/wp-json\/wp\/v2\/media\/136"}],"wp:attachment":[{"href":"https:\/\/benlongkj.com\/fr\/wp-json\/wp\/v2\/media?parent=137"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/benlongkj.com\/fr\/wp-json\/wp\/v2\/product_brand?post=137"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/benlongkj.com\/fr\/wp-json\/wp\/v2\/product_cat?post=137"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/benlongkj.com\/fr\/wp-json\/wp\/v2\/product_tag?post=137"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}