{"id":2122,"date":"2026-11-24T16:42:39","date_gmt":"2026-11-24T16:42:39","guid":{"rendered":"https:\/\/benlongkj.com\/?p=2122"},"modified":"2026-11-24T17:17:12","modified_gmt":"2026-11-24T17:17:12","slug":"what-are-the-different-types-of-testing-equipment","status":"publish","type":"post","link":"https:\/\/benlongkj.com\/fa\/blog\/what-are-the-different-types-of-testing-equipment\/","title":{"rendered":"\u0627\u0646\u0648\u0627\u0639 \u0645\u062e\u062a\u0644\u0641 \u062a\u062c\u0647\u06cc\u0632\u0627\u062a \u062a\u0633\u062a \u0686\u06cc\u0633\u062a\u061f"},"content":{"rendered":"<p>Manufacturing testing equipment can be divided into six categories: electrical safety and dielectric testing; function and performance test benches; automated inspection\/test stations (vision\/dimensions, force); environmental\/reliability chambers; end-of-line pass\/fail stations; calibration\/metrology equipment.<\/p>\n<blockquote><p><strong>\u067e\u0627\u0633\u062e \u0633\u0631\u06cc\u0639:<\/strong> the term \u201cautomated testing\u201d refers to performing tests at production speed, so 30 seconds for manual testing creates delays in production but does not cause a bottleneck in quality control if automated. An example of an automated test system is a complete electrical test bench for circuit breakers and contactors; this falls under Harmonized System code 9031.20.<\/p><\/blockquote>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2123\" src=\"https:\/\/benlongkj.com\/wp-content\/uploads\/2026\/11\/What-Are-the-Different-Types-of-Testing-Equipment.webp\" alt=\"\u0627\u0646\u0648\u0627\u0639 \u0645\u062e\u062a\u0644\u0641 \u062a\u062c\u0647\u06cc\u0632\u0627\u062a \u062a\u0633\u062a \u0686\u06cc\u0633\u062a\u0646\u062f\u061f\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>Six Families, and What Each One Proves<\/h2>\n<table>\n<thead>\n<tr>\n<th>Family<\/th>\n<th>\u0622\u0646\u0686\u0647 \u0627\u062b\u0628\u0627\u062a \u0645\u06cc\u200c\u06a9\u0646\u062f<\/th>\n<th>Typical station<\/th>\n<th>Where it is bought<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Electrical safety<\/td>\n<td>Insulation, dielectric strength, earth continuity, leakage<\/td>\n<td>Hipot and safety compliance tester<\/td>\n<td>Switchgear, appliances, motors, cables<\/td>\n<\/tr>\n<tr>\n<td>Functional and performance<\/td>\n<td>The product does what the datasheet says<\/td>\n<td>Custom bench with a current source and a data logger<\/td>\n<td>Breakers, contactors, relays, drives<\/td>\n<\/tr>\n<tr>\n<td>Automated inspection<\/td>\n<td>Appearance, dimensions, assembly correctness<\/td>\n<td>Vision cell, force gauge, laser scan<\/td>\n<td>Plastics, terminals, stamped parts, assemblies<\/td>\n<\/tr>\n<tr>\n<td>Environmental and reliability<\/td>\n<td>The product survives its life<\/td>\n<td>Thermal chamber, vibration table, aging rack<\/td>\n<td>Anything with a warranty<\/td>\n<\/tr>\n<tr>\n<td>End-of-line<\/td>\n<td>Pass or fail, fast, on every unit<\/td>\n<td>Fixture plus tester plus reject gate<\/td>\n<td>High-volume assembly<\/td>\n<\/tr>\n<tr>\n<td>Calibration and metrology<\/td>\n<td>The other five are telling the truth<\/td>\n<td>Reference standards, calibration bench<\/td>\n<td>Every plant that keeps records<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The last row is the first one to be eliminated, even though, in the end, it costs the most money. <span style=\"color: #c00000;\">A Test Bench that has never had Calibration performed produces numbers that do not have Traceability.<\/span> During a Customer Audit, the company will discover this fact long before it finds any defective products.<\/p>\n<h2>Electrical Safety and Dielectric Testing<\/h2>\n<p>Safety Testing is also a Family with Legal Obligations. The Hipot Test applies High Voltage to a Live Part and Earth or between Two Circuits. It Measures Whether or Not the Insulation Holds up. The typical dielectric withstand test for a 230 V AC appliance is <strong>1,500 V AC<\/strong> for one minute, while for switchgear assemblies, the dielectric withstand test is performed at the appropriate levels defined by the standards for that class of equipment. For example, a standard 12 kV switchgear assembly is tested at 28 kV of power frequency (50 Hz or 60 Hz).<\/p>\n<p>All three test methods for switchgear are complementary to each other. An earth continuity test proves that the protective conductor has low resistance and is properly terminated; typically, this resistance will be less than <strong>0.1 ohm<\/strong>. An insulation resistance test means that the insulation on the switchgear meets or exceeds its minimum requirements; typically, this will be a minimum of 1 megohm when tested at a voltage of 500 V DC.<\/p>\n<p>A leakage current test determines whether the amount of leakage current is within acceptable limits; measures of leakage current are made in milliamps (mA). The allowable limit of leakage current depends on the standard and the product class, and it will impact the ability of a manufacturer to sell a product in a market.<\/p>\n<p>Equipment for these tests is commercially available and typically purchased; however, the way in which the test fixture is set up (i.e., how parts of the product being tested are positioned and probe locations) and the duration of the test are not standardised. If a safety tester requires 40 seconds of operator handling for each unit tested, then it becomes a bottleneck if testing at a rate of 300 units\/hour, which is when fixture design becomes more important than the tester itself.<\/p>\n<h2>Functional and Performance Benches<\/h2>\n<p>Functionally, a functional performance bench demonstrates that the equipment (for example, an electrical circuit breaker) operates according to prescribed performance requirements. Usually, functional performance test benches are built for this purpose. A typical functional performance test bench is designed to replicate a minimum rated current and a multitude of times that current, for measuring the delay of trip, and for measuring the contact resistance of the electrical circuit breaker.<\/p>\n<p>The most substantial form of a test bench for electrical circuit breakers is an air-type circuit breaker test bench. To test the thermal element, to conduct the magnetic trip test, to measure contact resistance in the micro ohms range, and to run a dielectric test on the same fixture, a minimum of 1,000 A has to be produced and maintained for a controlled duration. The type of equipment used to deliver this current is the expensive part; this is the explanation for the fourfold differences observed in the cost of two quotations for a single \u201cbreaker test bench\u201d.<\/p>\n<p>The <a href=\"https:\/\/benlongkj.com\/fa\/acb-test-bench-product\/\">\u0645\u06cc\u0632 \u0622\u0632\u0645\u0627\u06cc\u0634 ACB<\/a> is an example of this format; it allows you to perform a contact resistance measurement, determine trip characteristics, and perform a dielectric withstand test at one test station, with a current source sized to the frame as opposed to a nominal value. The same reasoning applies to moulded case circuit breakers (MCCBs) and miniature circuit breakers (MCBs), where testing is quicker, and the current source is smaller.<\/p>\n<p>There are two specifications that establish the cost of any functional test bench. The first is the current range and the duty cycle of that current range; that is, how long it will hold the current before thermal drift occurs. The second specification is the uncertainty of measurement associated with the channel that measures trip time. A bench with a trip time measurement of 10 ms is suitable for a thermal test; a bench with a trip time measurement of 1 ms is needed to complete a magnetic trip test on a small device.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2124\" src=\"https:\/\/benlongkj.com\/wp-content\/uploads\/2026\/11\/Six-Families-of-testing.webp\" alt=\"Six Families of testing\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>Automated Inspection: Vision, Dimensional and Force<\/h2>\n<p>Inspection equipment answers a different question than does functional testing. The question asked is whether the part was manufactured correctly, not whether the part functions correctly. The distinction between the two types of inspections is important because a component with a defective assembly may pass a functional test today, then six months later fail due to the same defect, whereas it would be caught during an inspection at the time of assembly.<\/p>\n<p>The inspection process for defects in an assembly consists of three main elements: machine vision, dimensional measurement, and force\/torque measurement. Machine vision includes detecting presence or absence, location, colour, and defects on the surface of the part. A camera, lighting, and a trained machine vision model will determine whether the part passes or fails in 200 to 500 milliseconds, which is sufficient for a production line. The model can also be trained repeatedly based on new defect modes. The only downside of a machine vision system is that it can only detect what it was trained on, and any new defects would require retraining instead of an additional rule.<\/p>\n<p>Dimensional measurement processes will measure what machine vision is unable to measure (e.g., thread depth, bore diameter, terminal height); both laser triangulation and contact probe technology are used, depending on the tolerances\/finish of the part. Force and torque measurement processes will measure the crimp pull and terminal push-in, as well as the switch actuation. These three measurements correlate most closely to field failures of wiring devices.<\/p>\n<p>A machine vision inspection cell\u2019s economics differ from a functional test bench. The inspection cell is replacing inspection labor as opposed to the functional test time that a test bench replaces; thus, the payback can be measured in labor rather than test time(s). The <a href=\"https:\/\/benlongkj.com\/fa\/blog\/automated-visual-inspection-technology\/\">technologies associated with automated visual inspection<\/a> cover the lighting and model selection, so more false rejects result from poor lighting and model selection than from the camera.<\/p>\n<h2>Environmental and Reliability Testing<\/h2>\n<p>Reliability testing is not a production test.<\/p>\n<p>Manufacturers use a sample for an extended period each week in order to identify the modes of failure before the customer detects them. Their equipment consists of two chambers, a shaker, and a combination rack of each unit, running through a cycle of tests: vibration, thermal and humidity.<\/p>\n<p>To simulate \u201cThermal Cycling,\u201d they take the unit from a minimum of -40 to a maximum of +85 degrees Celsius on a predetermined number of cycles. The humid cycles are where the units will go through condensation. Electrical failures typically originate during condensation. Vibrational testing simulates the shipment and service environments and generally finds terminals that were left loose or not tightened during manufacture instead of a design defect.<\/p>\n<p>The most representative reliability test for switching products that would have the most meaningful data would be an Aging\/Endurance rack. The transfer switch will undergo 6,000 operations throughout its product life. Each time the transfer switch is operated, it will be done unattended with the recording of both the contact resistance drifted at specified intervals along the pathway. This enables the engineer to predict when resistance failure will occur.<\/p>\n<p>An example of this format is <a href=\"https:\/\/benlongkj.com\/fa\/ats-aging-test-bench-product\/\">the ATS aging test bench<\/a>, which requires that transfer switches run through thousands of operations unattended while recording drifting. The value of the results of the tests are not found by the pass or fail of the tests towards the end, but rather by the trends recorded during the tests that provide an indication to the engineer if the product design has margin or just fits within the established tolerance limits.<\/p>\n<p>Environmental Equipment is typically purchased rather than built. The exception to this is for the Fixturing that will be used to hold the product in the chambers. Incorrect chamber tests or chamber tests that permit product mobility create an irreproducible result.<\/p>\n<h2>End-of-Line Testing Versus In-Process Testing<\/h2>\n<p>End of line Testing is the final verification to determine if an entire unit can be shipped. In-process Testing helps determine whether or not a \u201cgood\u201d part will be forwarded to the next stage of production. Both services provide Testing Equipment; however, the funding for the equipment and the timing of the tests can be different.<\/p>\n<p>The end of line station is the traditional Test Station, with the following layout: a fixture, a testing device, one green\/one red lamp, and one reject\/accept gate. The end of line station tests all of the completed units on line; tests each unit from 10 to 60 seconds in duration and is used solely to prevent the escape of non-conforming units. The end of line station cannot identify the cause of failure \u2014 it can only identify that the unit has failed. It is for this reason that in a mature assembly plant the next station following the end-of-line station is the Diagnostic Bench, and the purpose of the Diagnostic Bench is to troubleshoot failed units.<\/p>\n<p>In-process testing is performed throughout the assembly process in a manner different than the end-of-line tests. The In-process Testing measures a given characteristic rather than inspecting the product itself. Examples of In-process Testing include Torque Testing after the Terminal has been installed, Resistance Testing after the Weld has been performed, and a Visual Inspection post-application of a Label. The Testing Equipment for in-process testing is less costly, requires less time to perform, and detects defects as close as possible to the station where they were created; this makes them the least expensive location to catch a defect.<\/p>\n<p><span style=\"color: #c00000;\">The general assembly economic principle states that a defect caught at the assembly station will cost one unit of rework.<\/span> At the end of line Testing, the cost for reworking a defect is ten units, and catching a defect at the end consumer location will cost the manufacturer one hundred. This ratio shows that there is a good reason to conduct tests on parts while they are still being manufactured, even if the company already has an end-of-line testing station.<\/p>\n<h2>Manual, Semi-Automatic and Automatic: The Payback Question<\/h2>\n<p>There are four basic types of testing stations: <a href=\"https:\/\/benlongkj.com\/fa\/blog\/difference-between-manual-and-automation-testing\/\">manual, semi-automatic, automatic, and inline automatic<\/a>.<\/p>\n<p>The table below shows some key differences between these four testing modes.<\/p>\n<table>\n<thead>\n<tr>\n<th>Mode<\/th>\n<th>\u0632\u0645\u0627\u0646 \u0686\u0631\u062e\u0647<\/th>\n<th>Operator content<\/th>\n<th>Relative cost<\/th>\n<th>Fits when<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0648 \u0622\u0632\u0645\u0627\u06cc\u0634<\/td>\n<td>2 to 10 minutes<\/td>\n<td>Full, including judgement<\/td>\n<td>1x<\/td>\n<td>Low volume, many variants, prototype<\/td>\n<\/tr>\n<tr>\n<td>\u0646\u06cc\u0645\u0647\u200c\u062e\u0648\u062f\u06a9\u0627\u0631<\/td>\n<td>30 to 90 seconds<\/td>\n<td>Load, unload, start<\/td>\n<td>4x to 8x<\/td>\n<td>Medium volume, one or two variants<\/td>\n<\/tr>\n<tr>\n<td>Automatic<\/td>\n<td>10 to 30 seconds<\/td>\n<td>None during the cycle<\/td>\n<td>12x to 25x<\/td>\n<td>High volume, stable design<\/td>\n<\/tr>\n<tr>\n<td>In-line automatic<\/td>\n<td>Line rate<\/td>\n<td>None, integrated with conveyor<\/td>\n<td>25x and up<\/td>\n<td>Continuous flow, one product family<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The three inputs into the calculation of return on investment (ROI) are the labour savings, the scrap and rework saved, and the capacity released by reducing the cycle time of your testing process.<\/p>\n<p>Labour costs are relatively easy to identify and quantify. The scrap and rework costs will typically be significantly greater than the labour cost. The additional capacity released by increasing throughput is often the most critical number to use to determine which type of station will provide the best payback for your manufacturing operation.<\/p>\n<p>By removing the testing burden on a station and converting a six-minute test to a 40-second test, you have not only reduced the labour cost by five minutes and 20 seconds, but you have also converted the testing station from a bottleneck into a pass-through for the tested parts. The additional throughput created by removing the testing burden is significantly greater than the labour cost savings and is the reason that throughput is often placed ahead of labour cost savings in the ROI calculations of testing device and automation comparisons.<\/p>\n<p>The only condition that will break the ROI calculation is product variety. While an automatic test station will run very quickly when an operator uses the product design for which the testing station was designed, an automatic test station will run very slowly with any other product. The reason for this is that switching to testing a different product requires changing out fixtures and often a change in programming. Semi-automatic benches that have quick-change fixtures are more appropriate than fully automated devices for production facilities that have forty different types and less than ten units per type.<\/p>\n<h2>What the Equipment Has to Produce Besides a Pass<\/h2>\n<p>The output of today\u2019s test stands is a record that has a higher value than the test completion. Suppliers will provide four outputs when they are audited by customers: 1. The measured value is needed, rather than just the result, so a trend is created prior to reaching the maximum allowable limit; 2. The time at which the measurement was taken and the operator identification number to trace back to the batch; 3. The serial number associated with the measured values, thus transforming a test into a certification; 4. The fixture and calibration status so that the measurement can be validated after the passage of time (up to one year from the time of initial measurement).<\/p>\n<p>Only a green light on a bench does not support a warranty claim or an audit. Therefore, the cost of the software used on test benches is <strong>15\u201330%<\/strong> of the equipment cost and is often the decisive factor that allows a facility to respond to customer inquiries regarding the specific unit.<\/p>\n<p>The same principles apply to the equipment being tested as they do to the testers. A device with a test point for every Critical Parameter can be tested within 30 seconds, while a device without test points must have a fixture to probe ten different points and will take approximately two minutes to test. Testability is a decision made before the machine is ordered.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2125\" src=\"https:\/\/benlongkj.com\/wp-content\/uploads\/2026\/11\/Choosing-a-Machine-Five-Specifications-That-Decide-It.webp\" alt=\"Choosing a Machine Five Specifications That Decide It\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>Choosing a Machine: Five Specifications That Decide It<\/h2>\n<p>The first five specifications are the key to differentiating between a machine that will work and one that will be returned.<\/p>\n<p>Current or force range and its duty cycle, the channel measurement uncertainty, cycle time with load and unload, cycle time for changeover of variant, and the data interface, meaning a mechanical means of transferring data from the machine to the facility without manual entry.<\/p>\n<p>The Calibration Interval for the test bench is the first specification outside of the Machine: a machine that requires factory service for annual calibration will spend an average of two weeks per year out of service, and this should be included in the project plan.<\/p>\n<p>In cases where the product is a Switching Device, the Test Bench should also verify the Protection Function as well as the Conduction Path. An MCB can carry current correctly and still trip wrongly at a multiple of its rating, while the continuity test passes. Consequently, the trip test cannot be skipped.<\/p>\n<h2>How Different Industries Buy Differently<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u0635\u0646\u0639\u062a<\/th>\n<th>Dominant test type<\/th>\n<th>Typical station<\/th>\n<th>What drives the purchase<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Low voltage switching devices<\/td>\n<td>Functional and trip test<\/td>\n<td>Automatic bench, 20 to 40 s<\/td>\n<td>Throughput and traceability<\/td>\n<\/tr>\n<tr>\n<td>Medium voltage switchgear<\/td>\n<td>Dielectric and mechanical<\/td>\n<td>Hipot plus operation counter<\/td>\n<td>Standard compliance and witness test<\/td>\n<\/tr>\n<tr>\n<td>Motors and pumps<\/td>\n<td>Performance and vibration<\/td>\n<td>Dynamometer or loaded run<\/td>\n<td>Efficiency class and noise<\/td>\n<\/tr>\n<tr>\n<td>Electronics assembly<\/td>\n<td>In-circuit and functional<\/td>\n<td>ICT plus flying probe<\/td>\n<td>Fault coverage and first-pass yield<\/td>\n<\/tr>\n<tr>\n<td>Plastics and stampings<\/td>\n<td>Dimensional and visual<\/td>\n<td>Vision cell<\/td>\n<td>Scrap rate and labour<\/td>\n<\/tr>\n<tr>\n<td>\u062f\u0633\u062a\u06af\u0627\u0647\u200c\u0647\u0627\u06cc \u067e\u0632\u0634\u06a9\u06cc<\/td>\n<td>Traceable functional<\/td>\n<td>Validated bench with audit trail<\/td>\n<td>Regulatory validation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>To read this table, find the column that matches your constraint. A plant limited by its labour will make inspections, while a plant limited by warranty cost will make purchases based on reliability. A plant limited by audits will make purchases based on traceability (a software function, not a machine function).<\/p>\n<p>For tests that are already automated, and the constraint has moved down the line, the answer is usually an automatic assembly line that contains the test with the product, rather than a larger bench. The <a href=\"https:\/\/benlongkj.com\/fa\/assembly-line-product\/\">\u0645\u062d\u0635\u0648\u0644\u0627\u062a \u062e\u0637 \u0645\u0648\u0646\u062a\u0627\u0698 \u0642\u0627\u0628\u0644 \u0627\u0639\u062a\u0645\u0627\u062f<\/a> that we manufacture, incorporate testing stations throughout the production process to test each unit as it is built and not at the end of the process in a batch.<\/p>\n<h2>Adjacent Categories That Are Not Production Testing<\/h2>\n<p>There are three categories of items that come up in a search with the above and these do not relate to an end-user manufacturer buying for a production line. The confusion caused by referring to all of these groups as Testing Equipment may waste a buyer\u2019s time on a procurement cycle.<\/p>\n<p>PAT Testing (Portable Appliance Testing) is essentially an in-service inspection of appliances in use and is not a manufacturing test. Laboratory, Water Testing and Soil Testing represent Analytic Chem testing. Testing and Commissioning of Electrical Equipment occurs at the installation site and uses portable instrumentation rather than a test bench.<\/p>\n<p>All three of these groups are legitimate purchases and all three fall under the Testing Equipment terminology. A buyer who is trying to locate a test bench for his or her production line, only to discover a page about PAT Testing, has arrived at the wrong family of products. The first question asked for any due diligence regarding Testing Equipment should be, \u201cWhat is to be proved and what is the production rate?\u201d<\/p>\n<h2>\u0633\u0648\u0627\u0644\u0627\u062a \u0645\u062a\u062f\u0627\u0648\u0644<\/h2>\n<h3>What is testing equipment?<\/h3>\n<p>Testing equipment is any instrument or test assembly used to verify that a material or product has met established requirements. The term \u201ctest station\u201d in many manufacturing applications typically refers to a station that can measure a specific value, compare that value to a defined maximum and minimum allowable limit, and then create a record of the result. Conversely, a hand-held meter typically provides a single output value that the user sees, meaning it does not provide an immediate assessment as does a test station.<\/p>\n<h3>What are the best electrical testing devices?<\/h3>\n<p>Because all types of electrical test devices serve different purposes and require different levels of specification, there is no such thing as a \u201cone size fits all\u201d definition of what a best test device is. For example, in switchgear assemblies, the most critical items that must be tested are dielectric withstand and contact resistance; for wiring devices, the trip characteristics and terminal pull; and for appliances, the insulation resistance and leakage current. The best device for an individual manufacturer will be the device that provides the level of accuracy, and overall performance, to match the particular specifications for the products and production rates being produced.<\/p>\n<h3>What are the types of electrical test machines?<\/h3>\n<p>A six-family grouping of different types of electrical test machines covers the manufacturing process. Electrical Safety and Dielectrics, Functional and Performance, Automated Inspection, Environmental and Reliability, End-of-Line Pass\/Fail, and Calibration and Metrology are all categorized within these families. They provide specific answers to specific problems and most manufacturers have a minimum of three different types of these test devices.<\/p>\n<h3>What are testing devices?<\/h3>\n<p>Testing devices consist of all of the instruments that are used for testing in test stations. A hipot tester, a micro-ohmmeter, a current source, a vision camera, a force gauge, and a data logger are all types of testing devices. The testing device measures, while the fixture holds the product and the software makes the decision and records the results. The primary reason that most test stations underperform is that a manufacturer buys a new test device and does not design the fixture it will operate in.<\/p>\n<h2>\u0645\u0646\u0627\u0628\u0639<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.ul.com\/\" rel=\"nofollow noopener\" target=\"_blank\">UL Solutions \u2014 Product Safety Testing and Certification Requirements<\/a><\/li>\n<li><a href=\"https:\/\/www.intertek.com\/\" rel=\"nofollow noopener\" target=\"_blank\">Intertek \u2014 Electrical Safety and Performance Test Services<\/a><\/li>\n<li><a href=\"https:\/\/www.keyence.com\/\" rel=\"nofollow noopener\" target=\"_blank\">Keyence \u2014 Machine Vision and Measurement Systems<\/a><\/li>\n<li><a href=\"https:\/\/www.chroma.com\/\" rel=\"nofollow noopener\" target=\"_blank\">Chroma ATE \u2014 Automated Test Systems and Power Test Instruments<\/a><\/li>\n<li><a href=\"https:\/\/www.automate.org\/\" rel=\"nofollow noopener\" target=\"_blank\">A3 \u2014 Advancing Automation, Vision and Motion Control<\/a><\/li>\n<\/ul>\n<h2>\u0646\u062a\u06cc\u062c\u0647\u200c\u06af\u06cc\u0631\u06cc<\/h2>\n<p>There are six types of testing equipment families used in manufacturing, and each of these families provides an answer to a manufacturer: safety compliance, functional performance to the product specifications, non-labour inspection, reliability assurance via warranty, end-of-line verification to the product defect rate, and the calibration of the test equipment used to assess the product\u2019s functionality and safety.<\/p>\n<p>The two key performance indicators that are required to determine whether a test station is going to be successful are its cycle time, including its handling time, as a fast test time with a slow product handling time = slow stations, and the amount of time it takes to changeover from one test version to another; an automatic bench that takes an entire shift to configure to a different version of a product is a bench for that one product only. Once those two items are resolved, the payback on the new test station is usually easy to calculate.<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Manufacturing testing equipment can be divided into six categories: electrical safety and dielectric testing; function and performance test benches; automated inspection\/test stations (vision\/dimensions, force); environmental\/reliability chambers; end-of-line pass\/fail stations; calibration\/metrology equipment. Quick answer: the term &#8220;automated testing&#8221; refers to performing tests at production speed, so 30 seconds for manual testing creates delays in production but [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2123,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-2122","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/benlongkj.com\/fa\/wp-json\/wp\/v2\/posts\/2122","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/benlongkj.com\/fa\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/benlongkj.com\/fa\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/fa\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/fa\/wp-json\/wp\/v2\/comments?post=2122"}],"version-history":[{"count":5,"href":"https:\/\/benlongkj.com\/fa\/wp-json\/wp\/v2\/posts\/2122\/revisions"}],"predecessor-version":[{"id":2130,"href":"https:\/\/benlongkj.com\/fa\/wp-json\/wp\/v2\/posts\/2122\/revisions\/2130"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/fa\/wp-json\/wp\/v2\/media\/2123"}],"wp:attachment":[{"href":"https:\/\/benlongkj.com\/fa\/wp-json\/wp\/v2\/media?parent=2122"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/benlongkj.com\/fa\/wp-json\/wp\/v2\/categories?post=2122"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/benlongkj.com\/fa\/wp-json\/wp\/v2\/tags?post=2122"}],"curies":[{"name":"\u0648\u0631\u062f\u067e\u0631\u0633","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}