{"id":33,"date":"2026-06-01T10:37:39","date_gmt":"2026-06-01T10:37:39","guid":{"rendered":"https:\/\/khkrh7q1ur.wpdns.site\/product\/ac-contactor-comprehensive-test-machine\/"},"modified":"2026-07-30T07:45:57","modified_gmt":"2026-07-30T07:45:57","slug":"ac-contactor-comprehensive-test-machine-product","status":"publish","type":"product","link":"https:\/\/benlongkj.com\/es\/ac-contactor-comprehensive-test-machine-product\/","title":{"rendered":"M\u00e1quina de prueba integral para contactores de CA"},"content":{"rendered":"<div class=\"bl-pdp-wrapper\">\n<div class=\"bl-pdp-split\">\n<div class=\"bl-pdp-split-text\">\n<div class=\"bl-pdp-badge\">Prueba m\u00faltiple \u00b7 Cambio r\u00e1pido<\/div>\n<h1>Sistema autom\u00e1tico de pruebas completas para contactores de CA universales<\/h1>\n<p>El sistema integral de pruebas para contactores de CA es una soluci\u00f3n automatizada destinada a garantizar la calidad de los contactores de CA mediante pruebas de alto rendimiento. Automatiza todos los requisitos de ensayo funcional significativos de un contactor de CA en una \u00fanica ubicaci\u00f3n, incluyendo (1) la verificaci\u00f3n tanto de la separaci\u00f3n entre contactos como del sobrerecorrido de los contactos (2) el ensayo de la sincronizaci\u00f3n de los contactos del contactor de CA (3) la prueba de tensi\u00f3n de resistencia diel\u00e9ctrica (Hi-Pot) (4) la prueba de tensi\u00f3n de activaci\u00f3n y desactivaci\u00f3n (pull-in) (5) la prueba de sobretensi\u00f3n\/subtensi\u00f3n del contactor de CA. Esta soluci\u00f3n de pruebas integral cuenta con herramientas intercambiables y software dise\u00f1ado a medida; se trata de una soluci\u00f3n de pruebas \u00fanica y coherente para m\u00faltiples modelos de contactores de CA con diferentes especificaciones. Esta soluci\u00f3n mejora considerablemente el control de calidad de toda la planta de producci\u00f3n, al garantizar que la producci\u00f3n de su planta cumple con los requisitos de toda la planta de producci\u00f3n, al tiempo que proporciona la mayor eficiencia posible.<\/p>\n<p><span style=\"color: #2872fa; font-weight: 500;\">Entrega est\u00e1ndar: 45-60 d\u00edas | Herramientas de cambio r\u00e1pido | Compatible con m\u00faltiples modelos<\/span><\/p>\n<\/div>\n<div class=\"bl-pdp-split-media\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/AC-contactor-comprehensive-test-machine.webp\" alt=\"M\u00e1quina de prueba integral para contactores de CA\" \/><\/p>\n<div style=\"font-size: 11px; margin-top: 8px;\">Estaci\u00f3n de pruebas para contactores multifuncionales (producto real)<\/div>\n<\/div>\n<\/div>\n<div class=\"bl-pdp-definition\">\n<h2>\u00bfQu\u00e9 problemas resuelve esta m\u00e1quina de pruebas?<\/h2>\n<p>Las pruebas de los contactores de CA realizadas de forma tradicional suelen requerir una estaci\u00f3n independiente para varios tipos de pruebas, lo que exige instalaciones separadas para las pruebas de dimensiones mec\u00e1nicas (mec\u00e1nicas, sobrecarrera y sincronizaci\u00f3n), una estaci\u00f3n separada para las pruebas el\u00e9ctricas (alta tensi\u00f3n) y una estaci\u00f3n separada para el rendimiento de la bobina el\u00e9ctrica (activaci\u00f3n\/desactivaci\u00f3n frente a sobretensi\u00f3n\/subtensi\u00f3n); este m\u00e9todo puede resultar muy costoso, ya que requiere varios equipos y operarios, adem\u00e1s de que las diferencias entre los m\u00e9todos de los operarios pueden generar una mayor variabilidad. El uso de nuestra \u00fanica m\u00e1quina de ensayo integral automatizada para combinar todos los tipos de ensayos en una sola m\u00e1quina ahorrar\u00e1 un espacio considerable en la planta industrial, eliminar\u00e1 cualquier manipulaci\u00f3n adicional de los productos entre ensayos, reducir\u00e1 el tiempo que se tarda en cambiar los m\u00f3dulos de ensayo (CM) entre modelos, ya que no habr\u00e1 que sustituir herramientas, y daremos un \u00fanico resultado de \u2019aprobado\u2019 o \u00absuspenso\u00bb para cada contactor. El sistema de ensayo registrar\u00e1 todos los resultados de las pruebas para facilitar la trazabilidad y ayudar a los fabricantes a cumplir con los principios de gesti\u00f3n continua de la calidad definidos en las normas ISO 9001 e IEC 60947-4-1. Adem\u00e1s, todas las pruebas y los accesorios pueden fabricarse y configurarse a medida seg\u00fan los requisitos de nuestros clientes para su modelo espec\u00edfico de serie de contactores, debido a que se trata de un producto no est\u00e1ndar.<\/p>\n<div class=\"bl-pdp-feature-grid\">\n<div class=\"bl-pdp-feature-card\"><strong>Prueba de separaci\u00f3n de contacto y sobrerecorrido<\/strong>Utiliza sensores lineales de alta precisi\u00f3n para verificar que las paradas mec\u00e1nicas y el sobrepaso de contacto se ajustan a las especificaciones de dise\u00f1o.<\/p>\n<\/div>\n<div class=\"bl-pdp-feature-card\"><strong>Prueba de sincronizaci\u00f3n de contactos<\/strong>Se ha medido el tiempo transcurrido entre el cierre y la apertura de los contactos principales para garantizar que el proceso de conmutaci\u00f3n fuera equilibrado y que se redujera al m\u00ednimo la formaci\u00f3n de arcos el\u00e9ctricos.<\/p>\n<\/div>\n<div class=\"bl-pdp-feature-card\"><strong>Prueba de alta tensi\u00f3n y prueba diel\u00e9ctrica<\/strong>Para verificar la integridad del aislamiento seg\u00fan la norma IEC 60947-4-1, se aplica alta tensi\u00f3n entre la bobina o los contactos y tierra.<\/p>\n<\/div>\n<div class=\"bl-pdp-feature-card\"><strong>Prueba de recogida y liberaci\u00f3n<\/strong>Mide la tensi\u00f3n de ca\u00edda m\u00e1xima y la tensi\u00f3n de activaci\u00f3n m\u00ednima; la m\u00e1s alta no debe superar el 110% de la m\u00e1s baja.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"bl-pdp-gallery\">\n<h2>Capacidades de ensayo y ventajas para el cliente<\/h2>\n<div class=\"bl-pdp-gallery-grid\">\n<div class=\"bl-pdp-gallery-item\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Intelligence-Visibility.webp\" alt=\"Visibilidad de la inteligencia: monitorizaci\u00f3n en tiempo real\" \/><\/p>\n<div class=\"bl-pdp-gallery-caption\">Informaci\u00f3n y visibilidad: visualizaci\u00f3n en tiempo real de los par\u00e1metros y resultados de las pruebas<\/div>\n<\/div>\n<div class=\"bl-pdp-gallery-item\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Efficiency-Sustainability.webp\" alt=\"Eficiencia y sostenibilidad: ahorro de energ\u00eda\" \/><\/p>\n<div class=\"bl-pdp-gallery-caption\">Eficiencia y sostenibilidad: una sola estaci\u00f3n sustituye a entre cuatro y cinco comprobadores de funci\u00f3n \u00fanica<\/div>\n<\/div>\n<div class=\"bl-pdp-gallery-item\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Design-Integration.webp\" alt=\"Integraci\u00f3n del dise\u00f1o - ingenier\u00eda modular\" \/><\/p>\n<div class=\"bl-pdp-gallery-caption\">Dise\u00f1o e integraci\u00f3n: herramientas de cambio r\u00e1pido para m\u00faltiples modelos de contactores<\/div>\n<\/div>\n<div class=\"bl-pdp-gallery-item\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Safety-Reliability.webp\" alt=\"Fiabilidad y seguridad: pruebas rigurosas\" \/><\/p>\n<div class=\"bl-pdp-gallery-caption\">Seguridad y fiabilidad: zona cerrada para pruebas de alta tensi\u00f3n con protecci\u00f3n por enclavamiento<\/div>\n<\/div>\n<\/div>\n<\/div>\n<h2>Especificaciones t\u00e9cnicas<\/h2>\n<div class=\"bl-pdp-summary\">M\u00e1quina de ensayo integral para contactores de CA: separaci\u00f3n entre contactos\/recorrido excesivo, sincronizaci\u00f3n, ensayo de alta tensi\u00f3n, activaci\u00f3n\/desactivaci\u00f3n, sobretensi\u00f3n\/subtensi\u00f3n. Herramientas de cambio r\u00e1pido, evaluaci\u00f3n autom\u00e1tica de \u00abapto\/no apto\u00bb.<\/div>\n<div class=\"bl-pdp-table-wrap\">\n<table class=\"bl-pdp-table\">\n<tbody>\n<tr>\n<th style=\"width: 35%;\">Funciones de prueba<\/th>\n<td>Distancia de contacto y sobrerecorrido, sincronizaci\u00f3n de contacto, prueba de alta tensi\u00f3n (rigidez diel\u00e9ctrica), tensi\u00f3n de activaci\u00f3n, tensi\u00f3n de desactivaci\u00f3n, sobretensi\u00f3n, subtensi\u00f3n\u2013<\/td>\n<\/tr>\n<tr>\n<th>Precisi\u00f3n en la medici\u00f3n de la distancia de contacto<\/th>\n<td>\u00b10,01 mm\u2013<\/td>\n<\/tr>\n<tr>\n<th>Precisi\u00f3n de la sincronizaci\u00f3n<\/th>\n<td>\u00b10,1 ms\u2013<\/td>\n<\/tr>\n<tr>\n<th>Voltaje de prueba Hi-Pot<\/th>\n<td>Programable hasta 2.500 V CA, duraci\u00f3n ajustable\u2013<\/td>\n<\/tr>\n<tr>\n<th>Precisi\u00f3n de la tensi\u00f3n de captaci\u00f3n\/liberaci\u00f3n<\/th>\n<td>\u00b111 minutos de lectura\u2013<\/td>\n<\/tr>\n<tr>\n<th>Duraci\u00f3n del ciclo de prueba<\/th>\n<td>Entre 15 y 30 segundos por contactor (dependiendo del n\u00famero de pruebas)\u2013<\/td>\n<\/tr>\n<tr>\n<th>Tipos de contactores compatibles<\/th>\n<td>Contactores de CA, varios tama\u00f1os de carcasa (9 A-95 A, hasta 400 A opcional)\u2013<\/td>\n<\/tr>\n<tr>\n<th>Tiempo de cambio<\/th>\n<td>&lt;5 minutos (cambio r\u00e1pido de utillaje + selecci\u00f3n de receta)\u2013<\/td>\n<\/tr>\n<tr>\n<th>Sistema de control<\/th>\n<td>PLC (Siemens) con HMI, capacidad para almacenar m\u00e1s de 50 recetas\u2013<\/td>\n<\/tr>\n<tr>\n<th>Fuente de alimentaci\u00f3n<\/th>\n<td>380 V \u00b110 % 3 fases 50 Hz | Circuito de alta tensi\u00f3n 220 V\u2013<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Principales ventajas para los clientes: por qu\u00e9 los fabricantes eligen este sistema<\/h2>\n<div class=\"bl-pdp-grid\">\n<div class=\"bl-pdp-card\">\n<h4>Ventaja 1: Consolidaci\u00f3n de pruebas 4 en 1<\/h4>\n<p>Al utilizar un solo equipo de prueba automatizado que realiza varias funciones de prueba diferentes (por ejemplo, distancia de contacto, sincronizaci\u00f3n, Hi-Pot y rendimiento de la bobina) en lugar de disponer de varias m\u00e1quinas para hacer lo mismo, se puede ahorrar hasta un 50 % en costes de capital y un 60 % en espacio f\u00edsico en comparaci\u00f3n con disponer de estaciones independientes para cada funci\u00f3n de prueba.<\/p>\n<\/div>\n<div class=\"bl-pdp-card\">\n<h4>Ventaja 2: Elimina la variaci\u00f3n provocada por la manipulaci\u00f3n<\/h4>\n<p>El desplazamiento de los contactores por las distintas estaciones de ensayo provoca variaciones en su posici\u00f3n e introduce cambios de temperatura. El ensayo de todos los par\u00e1metros de dise\u00f1o mediante un \u00fanico dise\u00f1o integrado permite medir el rendimiento de toda la m\u00e1quina sin tener que mover el producto, lo que proporciona resultados precisos y reproducibles.<\/p>\n<\/div>\n<div class=\"bl-pdp-card\">\n<h4>Ventaja 3: Cambio r\u00e1pido para la producci\u00f3n mixta<\/h4>\n<p>Las herramientas de cambio r\u00e1pido, como los dispositivos de sujeci\u00f3n de contactos y los conectores de bobinas, junto con una interfaz HMI basada en recetas, permiten al usuario cambiar de un modelo de contactor a otro en menos de cinco (5) minutos. Esto resulta especialmente \u00fatil para los fabricantes que producen muchas familias de productos diferentes.<\/p>\n<\/div>\n<div class=\"bl-pdp-card\">\n<h4>Ventaja 4: Registro autom\u00e1tico de datos para auditor\u00edas de calidad<\/h4>\n<p>A todos los resultados de las pruebas (valores de separaci\u00f3n, tiempo de sincronizaci\u00f3n, fugas en la prueba de alta tensi\u00f3n y tensiones de activaci\u00f3n) se les asignan los n\u00fameros de serie de los contactores, con el fin de garantizar que todas las pruebas se realicen de forma autom\u00e1tica, conservando un v\u00ednculo real con cada contactor concreto. Los resultados generados se pueden exportar y cumplen con las normas ISO 9001 e IEC.<\/p>\n<\/div>\n<\/div>\n<div class=\"bl-pdp-partners\"><span class=\"bl-pdp-partners-title\">Con la confianza de los l\u00edderes de la industria.<\/span><\/p>\n<div class=\"bl-pdp-partners-list\">\n<div class=\"bl-pdp-partner-item\"><img decoding=\"async\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738413289.webp\" alt=\"TEJIDO\" \/><\/div>\n<div class=\"bl-pdp-partner-item\"><img decoding=\"async\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\" src=\"\/wp-content\/uploads\/2026\/06\/1780594739263598.webp\" alt=\"DELIXI\" \/><\/div>\n<div class=\"bl-pdp-partner-item\"><img decoding=\"async\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\" src=\"\/wp-content\/uploads\/2026\/06\/1780594739675877.webp\" alt=\"EKF\" \/><\/div>\n<div class=\"bl-pdp-partner-item\"><img decoding=\"async\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\" src=\"\/wp-content\/uploads\/2026\/06\/1780594741141751.webp\" alt=\"KRIPAL\" \/><\/div>\n<div class=\"bl-pdp-partner-item\"><img decoding=\"async\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738593989.webp\" alt=\"HPL\" \/><\/div>\n<div class=\"bl-pdp-partner-item\"><img decoding=\"async\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738101609.webp\" alt=\"CHAC\" \/><\/div>\n<div class=\"bl-pdp-partner-item\"><img decoding=\"async\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738124777.webp\" alt=\"Schneider\" \/><\/div>\n<div class=\"bl-pdp-partner-item\"><img decoding=\"async\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738797907.webp\" alt=\"GRUPO IEK\" \/><\/div>\n<div class=\"bl-pdp-partner-item\"><img decoding=\"async\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738812289.webp\" alt=\"SUNIR\" \/><\/div>\n<div class=\"bl-pdp-partner-item\"><img decoding=\"async\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738411369.webp\" alt=\"Bevone\" \/><\/div>\n<div class=\"bl-pdp-partner-item\"><img decoding=\"async\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738389707.webp\" alt=\"Weg\" \/><\/div>\n<div class=\"bl-pdp-partner-item\"><img decoding=\"async\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738361034.webp\" alt=\"HUYU\" \/><\/div>\n<div class=\"bl-pdp-partner-item\"><img decoding=\"async\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738416677.webp\" alt=\"RAAD\" \/><\/div>\n<div class=\"bl-pdp-partner-item\"><img decoding=\"async\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738314557.webp\" alt=\"WALTONE\" \/><\/div>\n<div class=\"bl-pdp-partner-item\"><img decoding=\"async\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738445639.webp\" alt=\"HAVELLS\" \/><\/div>\n<div class=\"bl-pdp-partner-item\"><img decoding=\"async\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738720809.webp\" alt=\"C&amp;S el\u00e9ctrico\" \/><\/div>\n<\/div>\n<\/div>\n<div class=\"bl-pdp-case\">\n<h3>\u00c9xito de los clientes: c\u00f3mo un fabricante de contactores redujo el tiempo de prueba en un 60%<\/h3>\n<p>Un fabricante europeo de contactores contaba con un total de cuatro estaciones de prueba (mec\u00e1nica, de sincronizaci\u00f3n, de alta tensi\u00f3n y de tensi\u00f3n de bobina) para sus contactores. Cada contactor tardaba 2 minutos en pasar por las distintas estaciones de prueba y se necesitaban 3 operarios para manejarlas. Gracias a la implantaci\u00f3n de esta m\u00e1quina de pruebas integral, pudieron:<\/p>\n<div class=\"bl-pdp-case-stats\">\n<div class=\"bl-pdp-case-stat\"><strong>25 s\/contactor<\/strong> Tiempo total de la prueba (una reducci\u00f3n con respecto a los 120 segundos)<\/div>\n<div class=\"bl-pdp-case-stat\"><strong>1 operador<\/strong> (sustituido por 3)<\/div>\n<div class=\"bl-pdp-case-stat\"><strong>100%<\/strong> Repetibilidad de la prueba (variaci\u00f3n entre estaciones eliminada)<\/div>\n<\/div>\n<p style=\"margin-top: 12px; font-size: 14px;\">La m\u00e1quina se amortiz\u00f3 en 10 meses y liber\u00f3 12 m\u00b2 de espacio en la planta de producci\u00f3n.<\/p>\n<\/div>\n<h2>Aplicaciones: d\u00f3nde aporta mayor valor esta m\u00e1quina<\/h2>\n<div class=\"bl-pdp-feature\">\n<div class=\"bl-pdp-feature-list\">\n<div class=\"bl-pdp-feature-item\"><strong>L\u00edneas de fabricaci\u00f3n de contactores de CA<\/strong> \u2013 Pruebas finales en l\u00ednea antes del embalaje<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Laboratorios de control de calidad<\/strong> \u2013 Muestreo rutinario y ensayos de tipo<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Inspecci\u00f3n entrante<\/strong> \u2013 Comprobaci\u00f3n de los contactores adquiridos a los proveedores<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Validaci\u00f3n de I+D<\/strong> \u2013 Caracterizaci\u00f3n de nuevos dise\u00f1os de contactores<\/div>\n<\/div>\n<\/div>\n<h2>Ingenier\u00eda y entrega a medida<\/h2>\n<div class=\"bl-pdp-steps\">\n<div class=\"bl-pdp-step\"><strong>1. An\u00e1lisis de muestras de contactores<\/strong> 10-20 d\u00edas \u00b7 tama\u00f1o del armaz\u00f3n, tensi\u00f3n de la bobina, configuraci\u00f3n de los contactos<\/div>\n<div class=\"bl-pdp-step\"><strong>2. Dise\u00f1o de accesorios y recetas<\/strong> 15-25 d\u00edas \u00b7 cambio r\u00e1pido de utillaje, secuencia de pruebas<\/div>\n<div class=\"bl-pdp-step\"><strong>3. Fabricaci\u00f3n y montaje<\/strong> 45-60 d\u00edas<\/div>\n<div class=\"bl-pdp-step\"><strong>4. Pre-FAT<\/strong> En la f\u00e1brica de Benlong<\/div>\n<div class=\"bl-pdp-step\"><strong>5. Instalaci\u00f3n y formaci\u00f3n<\/strong> Entre 3 y 5 d\u00edas en el lugar<\/div>\n<div class=\"bl-pdp-step\"><strong>6. Examen final del SAT<\/strong> 3-5 d\u00edas \u00b7 informe de aceptaci\u00f3n<\/div>\n<\/div>\n<div class=\"bl-pdp-cta\">\n<h2>Solicite un presupuesto personalizado para un sistema de pruebas de contactores de CA<\/h2>\n<p>Le rogamos que nos env\u00ede muestras de su producto, as\u00ed como sus requisitos para las pruebas, y le proporcionaremos un dise\u00f1o de una m\u00e1quina de pruebas completa, con herramientas de cambio r\u00e1pido y capacidad para m\u00faltiples modelos, desde folletos hasta un an\u00e1lisis completo del retorno de la inversi\u00f3n.<\/p>\n<p><a class=\"bl-pdp-btn\" href=\"\/es\/contact\/\">Consulta ahora<\/a><\/p>\n<p class=\"bl-pdp-footnote\">WhatsApp: +86 150 5837 0007 | Correo electr\u00f3nico: xsb@benlongkj.cn | Soporte en ingl\u00e9s y chino<\/p>\n<\/div>\n<div class=\"bl-pdp-two-col\">\n<div class=\"bl-pdp-col-main\">\n<h3>\u00bfPor qu\u00e9 elegir Benlong para la automatizaci\u00f3n de pruebas de contactores?<\/h3>\n<ul>\n<li>M\u00e1s de 15 a\u00f1os dise\u00f1ando <strong>sistemas de ensayo integrales<\/strong> para componentes el\u00e9ctricos de baja tensi\u00f3n<\/li>\n<li>Integraci\u00f3n probada de ensayos mec\u00e1nicos, el\u00e9ctricos y diel\u00e9ctricos en una sola estaci\u00f3n<\/li>\n<li>Herramientas de cambio r\u00e1pido: cambio entre modelos en menos de 5 minutos<\/li>\n<li>Registro completo de datos y conectividad con el sistema de ejecuci\u00f3n de fabricaci\u00f3n (MES) (OPC UA \/ Modbus)<\/li>\n<li>Soporte t\u00e9cnico y de repuestos a nivel mundial<\/li>\n<\/ul>\n<\/div>\n<div class=\"bl-pdp-col-side\">\n<h3>La m\u00e1quina est\u00e1ndar incluye<\/h3>\n<p>Sensor de holgura\/recorrido excesivo (encoder lineal) \u2264 M\u00f3dulo de medici\u00f3n de sincronizaci\u00f3n \u2264 Comprobador de alta tensi\u00f3n (2,5 kV) \u2264 Fuente de alimentaci\u00f3n de CA programable para pruebas de bobinas \u2264 Juego de accesorios de cambio r\u00e1pido \u2264 PLC con IHM: Siemens \u2264 Software de registro de datos \u2264 Caja de seguridad \u2264 Manual de instrucciones \u2264 1 a\u00f1o de garant\u00eda<\/p>\n<\/div>\n<\/div>\n<div class=\"bl-pdp-internal-links\"><span class=\"bl-pdp-internal-links-title\">Soluciones relacionadas<\/span><\/p>\n<div class=\"bl-pdp-links-list\"><a href=\"https:\/\/benlongkj.com\/es\/ac-contactor-automatic-contact-insertion-machine-product\/\">M\u00e1quina autom\u00e1tica para la inserci\u00f3n de contactos de contactores de CA<\/a><br \/>\n<a href=\"https:\/\/benlongkj.com\/es\/automatic-assembly-machine-for-ac-contactor-main-auxiliary-contacts-product\/\">M\u00e1quina de ensamblaje de tornillos para contactores de CA<\/a><br \/>\n<a href=\"https:\/\/benlongkj.com\/es\/contactor-coil-winding-machine-product\/\">M\u00e1quina para bobinar bobinas de contactores<\/a><br \/>\n<a href=\"https:\/\/benlongkj.com\/es\/mcb-automatic-testing-line\/\">L\u00ednea de prueba autom\u00e1tica de MCB<\/a><br \/>\n<a href=\"https:\/\/benlongkj.com\/es\/load-isolation-switch-automatic-testing-line-product\/\">L\u00ednea de prueba del interruptor de aislamiento de carga<\/a><br \/>\n<a href=\"https:\/\/benlongkj.com\/es\/mccb-semi-automatic-high-voltage-test-bench-product\/\">Banco de pruebas semiautom\u00e1tico de alta tensi\u00f3n para interruptores autom\u00e1ticos de caja moldeada (MCCB)<\/a><\/div>\n<\/div>\n<h2>Preguntas frecuentes<\/h2>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">\u00bfQu\u00e9 pruebas se incluyen en la configuraci\u00f3n est\u00e1ndar?<\/div>\n<p>La m\u00e1quina de pruebas predeterminada incluye las siguientes pruebas, generalmente aceptadas: comprobaci\u00f3n de la separaci\u00f3n entre contactos, comprobaci\u00f3n del final de carrera; comprobaci\u00f3n del retardo entre contactos; comprobaci\u00f3n de la rigidez diel\u00e9ctrica; comprobaci\u00f3n de la tensi\u00f3n de activaci\u00f3n, comprobaci\u00f3n de la tensi\u00f3n de liberaci\u00f3n; y comprobaci\u00f3n de la tensi\u00f3n tanto en el momento de la activaci\u00f3n como en el de la desactivaci\u00f3n. Si se desea, se pueden realizar otras pruebas (por ejemplo, resistencia de los contactos, resistencia de las bobinas).<\/p>\n<\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">\u00bfEsta m\u00e1quina puede probar tanto contactores de CA como de CC?<\/div>\n<p>El modelo est\u00e1ndar del sistema se utiliza junto con todos los contactores de CA (alimentados por bobina de CA); no obstante, como parte del proceso de asesoramiento, se pueden realizar modificaciones en la fuente de alimentaci\u00f3n y la l\u00f3gica de control para permitir el uso de otros tipos de contactores, como los de CC.<\/p>\n<\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">\u00bfCu\u00e1nto tiempo se tarda en cambiar entre diferentes modelos de contactores?<\/div>\n<p>El cambio de montaje mediante utillaje de cambio r\u00e1pido (dispositivos mec\u00e1nicos y conectores de bobinas) y la selecci\u00f3n de la receta a trav\u00e9s de la interfaz hombre-m\u00e1quina (HMI) requieren menos de 5 minutos para la mayor\u00eda de las familias de modelos.<\/p>\n<\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">\u00bfRegistra la m\u00e1quina los datos de las pruebas para las auditor\u00edas de calidad?<\/div>\n<p>Los resultados de las pruebas (valores de separaci\u00f3n, tiempo de sincronizaci\u00f3n, fugas en la prueba de alta tensi\u00f3n, tensiones de activaci\u00f3n\/desactivaci\u00f3n) se guardan en la memoria con una marca de fecha y hora, y pueden transferirse a trav\u00e9s de USB o al MES mediante OPC UA \/ Modbus TCP. Todos los resultados de las pruebas se almacenan con una marca de tiempo y pueden exportarse a un dispositivo USB o directamente al MES a trav\u00e9s de OPC UA\/Modbus TCP.<\/p>\n<\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">\u00bfCu\u00e1l es la duraci\u00f3n habitual del ciclo de prueba por contactor?<\/div>\n<p>El tiempo de ciclo por unidad, en funci\u00f3n del n\u00famero de pruebas, oscilar\u00e1 entre 15 y 30 segundos por unidad para las mediciones mec\u00e1nicas y las pruebas de alta tensi\u00f3n y de tensi\u00f3n de bobina.<\/p>\n<\/div>\n<div style=\"margin: 32px 0 16px; font-size: 12px; text-align: center; border-top: 1px solid #e9edf2; padding-top: 16px; color: #5f7d9c;\">Todas las especificaciones est\u00e1n sujetas a acuerdo t\u00e9cnico definitivo. Benlong Automation: soluciones integrales de pruebas de contactores de CA para fabricantes de equipos el\u00e9ctricos.<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Medici\u00f3n integral del tiempo de cierre\/apertura del contactor, tiempo de transferencia, sincronismo trif\u00e1sico, distancia de contacto y sobreviaje, resistencia diel\u00e9ctrica, conexi\u00f3n y desconexi\u00f3n, y adaptabilidad a sobre-\/bajo voltaje.<\/p>","protected":false},"featured_media":32,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[20],"product_tag":[],"class_list":["post-33","product","type-product","status-publish","has-post-thumbnail","product_cat-test-bench-project","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/benlongkj.com\/es\/wp-json\/wp\/v2\/product\/33","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/benlongkj.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/benlongkj.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/es\/wp-json\/wp\/v2\/comments?post=33"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/es\/wp-json\/wp\/v2\/media\/32"}],"wp:attachment":[{"href":"https:\/\/benlongkj.com\/es\/wp-json\/wp\/v2\/media?parent=33"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/benlongkj.com\/es\/wp-json\/wp\/v2\/product_brand?post=33"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/benlongkj.com\/es\/wp-json\/wp\/v2\/product_cat?post=33"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/benlongkj.com\/es\/wp-json\/wp\/v2\/product_tag?post=33"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}