{"id":27,"date":"2026-06-01T10:37:36","date_gmt":"2026-06-01T10:37:36","guid":{"rendered":"https:\/\/khkrh7q1ur.wpdns.site\/product\/auxiliary-and-signal-contact-test-bench\/"},"modified":"2026-06-10T07:29:08","modified_gmt":"2026-06-10T07:29:08","slug":"auxiliary-and-signal-contact-test-bench-product","status":"publish","type":"product","link":"https:\/\/benlongkj.com\/es\/auxiliary-and-signal-contact-test-bench-product\/","title":{"rendered":"Banco de pruebas de contacto auxiliar y de se\u00f1al"},"content":{"rendered":"<div class=\"bl-pdp-wrapper\">\n<div class=\"bl-pdp-split\">\n<div class=\"bl-pdp-split-text\">\n<div class=\"bl-pdp-badge\">L\u00f3gica de modo dual \u00b7 Resistencia de contacto<\/div>\n<h1>Banco de pruebas de contactos auxiliares y de se\u00f1al para RCBO\/MCB<\/h1>\n<p>Las pruebas autom\u00e1ticas y manuales de los contactos auxiliares y de alarma (o se\u00f1ales) se realizan en el banco de pruebas. El banco de pruebas confirmar\u00e1 que el estado del contacto ha cambiado de normal a inverso (o viceversa) cada vez que se abre o se cierra manualmente la palanca del interruptor (se comprueba el estado de un contacto auxiliar cada vez que una persona abre o cierra manualmente la palanca del interruptor). El banco de pruebas confirmar\u00e1 que el estado del contacto NO cambiar\u00e1 mientras se abre manualmente el interruptor (se verifica el estado de un contacto de alarma mientras una persona abre manualmente el interruptor) ni se modificar\u00e1 cuando se produzca una falla, pero S\u00cd cambiar\u00e1 de estado cuando se simule una desconexi\u00f3n por falla. (La simulaci\u00f3n se lleva a cabo bien mediante el bot\u00f3n de prueba del RCBO, bien provocando un cortocircuito total). El banco de pruebas tambi\u00e9n medir\u00e1 la resistencia del contacto auxiliar utilizando un microohm\u00edmetro y realizar\u00e1 pruebas de alta tensi\u00f3n para confirmar que no se produce ninguna corriente de fuga. El banco de pruebas es adecuado para laboratorios de control de calidad y l\u00edneas de producci\u00f3n, as\u00ed como para la inspecci\u00f3n a la recepci\u00f3n de un m\u00f3dulo de contacto auxiliar.<\/p>\n<p><span style=\"color: #2872fa; font-weight: 500;\">Entrega est\u00e1ndar: 30-45 d\u00edas | Pruebas l\u00f3gicas de modo dual | Resistencia de contacto y prueba de alta tensi\u00f3n<\/span><\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-split-media\">\n            <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Auxiliary-and-Signal-Contact-test-bench.webp\" alt=\"Banco de pruebas de contactos auxiliares y de se\u00f1al\"><\/p>\n<div style=\"font-size: 11px; margin-top: 8px;\">Estaci\u00f3n de pruebas de contacto de doble modo (producto real)<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-definition\">\n<h2>\u00bfQu\u00e9 problemas resuelve este banco de pruebas?<\/h2>\n<p>Los contactos auxiliares y de se\u00f1al son componentes esenciales a la hora de realizar la monitorizaci\u00f3n remota de los interruptores autom\u00e1ticos. Sin embargo, existen tres problemas principales comunes tanto a los fabricantes como a los usuarios de interruptores autom\u00e1ticos: una l\u00f3gica de conmutaci\u00f3n incorrecta (por ejemplo, la activaci\u00f3n de una alarma al abrir manualmente el interruptor, lo que genera falsas alarmas); alta resistencia de los contactos (la oxidaci\u00f3n de los contactos provocar\u00e1 la p\u00e9rdida de la transmisi\u00f3n de la se\u00f1al); y ruptura del aislamiento (lo que puede suponer un problema de seguridad). El banco de pruebas solucionar\u00e1 estos tres problemas mediante una secuencia probada para validar la l\u00f3gica de modo dual (auxiliar frente a alarma) y medir la resistencia de los contactos (para identificar los disyuntores averiados).<\/p>\n<div class=\"bl-pdp-feature-grid\">\n<div class=\"bl-pdp-feature-card\">\n                <strong>Verificaci\u00f3n l\u00f3gica de modo dual<\/strong><\/p>\n<p>Prueba el modo auxiliar (los contactos cambian al accionar la palanca) y el modo de alarma (los contactos solo cambian en caso de desconexi\u00f3n por fallo, pero no en caso de apertura manual).<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Medici\u00f3n de la resistencia de contacto<\/strong><\/p>\n<p>Mide la resistencia de los contactos cerrados (menos de 50 m\u03a9, t\u00edpicamente) y detecta la oxidaci\u00f3n o los malos contactos que pueden provocar fallos en la se\u00f1al.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Prueba de rigidez diel\u00e9ctrica (hi-pot)<\/strong><\/p>\n<p>Aplica una tensi\u00f3n de 1500 V o 2000 V CA entre los terminales para comprobar la integridad del aislamiento, seg\u00fan la norma IEC 60947-5-1.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Verificaci\u00f3n del enclavamiento mec\u00e1nico<\/strong><\/p>\n<p>Comprueba el correcto montaje y funcionamiento del contacto auxiliar\/de se\u00f1alizaci\u00f3n una vez instalado en un RCBO\/MCB.<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery\">\n<h2>Proceso de pruebas y ventajas para el cliente<\/h2>\n<div class=\"bl-pdp-gallery-grid\">\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Intelligence-Visibility.webp\" alt=\"Visibilidad de la inteligencia: monitorizaci\u00f3n en tiempo real\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Informaci\u00f3n y visibilidad: visualizaci\u00f3n en tiempo real del estado de los contactos (NO\/NC) y de los par\u00e1metros de prueba<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Efficiency-Sustainability.webp\" alt=\"Eficiencia y sostenibilidad: ahorro de energ\u00eda\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Eficiencia y sostenibilidad: la secuencia de pruebas automatizada reduce el tiempo dedicado a las pruebas manuales en un 80%<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Design-Integration.webp\" alt=\"Integraci\u00f3n del dise\u00f1o - ingenier\u00eda modular\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Dise\u00f1o e integraci\u00f3n: soporte universal para distintos modelos de contactos auxiliares<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Safety-Reliability.webp\" alt=\"Fiabilidad y seguridad: pruebas rigurosas\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Seguridad y fiabilidad: zona cerrada para pruebas de alta tensi\u00f3n con sistema de enclavamiento que protege al operario<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<h2>Especificaciones t\u00e9cnicas<\/h2>\n<div class=\"bl-pdp-summary\">Banco de pruebas para contactos auxiliares y de alarma. L\u00f3gica de doble modo (auxiliar\/alarma), resistencia de contacto (&lt;50 m\u03a9), prueba de alta tensi\u00f3n (1500 V\/2000 V CA), verificaci\u00f3n del enclavamiento mec\u00e1nico.<\/div>\n<div class=\"bl-pdp-table-wrap\">\n<table class=\"bl-pdp-table\">\n<tbody>\n<tr>\n<th style=\"width: 35%;\">Funciones de prueba<\/th>\n<td>L\u00f3gica del modo auxiliar, l\u00f3gica del modo de alarma, resistencia de contacto, rigidez diel\u00e9ctrica (prueba de alta tensi\u00f3n), enclavamiento mec\u00e1nico\n                <\/td>\n<\/tr>\n<tr>\n<th>Medici\u00f3n de la resistencia de contacto<\/th>\n<td>Rango: 0-200 m\u03a9, precisi\u00f3n: \u00b111 TP3T, corriente de prueba: 1 A CC (microohm\u00edmetro)\n                <\/td>\n<\/tr>\n<tr>\n<th>Aceptaci\u00f3n de la resistencia de contacto<\/th>\n<td>&lt;50 m\u03a9 (t\u00edpico), l\u00edmite programable\n                <\/td>\n<\/tr>\n<tr>\n<th>Tensi\u00f3n de prueba de alta tensi\u00f3n<\/th>\n<td>1500 V CA \/ 2000 V CA (programable, de 1 a 60 segundos)\n                <\/td>\n<\/tr>\n<tr>\n<th>Umbral de corriente de fuga<\/th>\n<td>Programable (por ejemplo, 5 mA, 10 mA)\n                <\/td>\n<\/tr>\n<tr>\n<th>Prueba del modo auxiliar<\/th>\n<td>Accionamiento manual de la maneta (cerrar\/abrir): comprobaci\u00f3n autom\u00e1tica de continuidad en los contactos NA\/NC\n                <\/td>\n<\/tr>\n<tr>\n<th>Prueba del modo de alarma: apertura manual<\/th>\n<td>El contacto NO debe cambiar de estado\n                <\/td>\n<\/tr>\n<tr>\n<th>Prueba del modo de alarma: simulaci\u00f3n de una desconexi\u00f3n por fallo<\/th>\n<td>El contacto debe cambiar de estado (NO \u2192 cerrado, NC \u2192 abierto) de forma instant\u00e1nea\n                <\/td>\n<\/tr>\n<tr>\n<th>M\u00e9todo de simulaci\u00f3n de la desconexi\u00f3n por fallo<\/th>\n<td>Para el RCBO: pulsaci\u00f3n autom\u00e1tica del bot\u00f3n \u201cT\u201d; para el MCB: inyecci\u00f3n de corriente de cortocircuito (opcional)\n                <\/td>\n<\/tr>\n<tr>\n<th>Fuente de alimentaci\u00f3n<\/th>\n<td>220 V \u00b1101 TP3T 50 Hz\n                <\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<h2>Principales ventajas para el cliente: por qu\u00e9 los fabricantes utilizan este banco de trabajo<\/h2>\n<div class=\"bl-pdp-grid\">\n<div class=\"bl-pdp-card\">\n<h4>Ventaja 1: Elimina las falsas alarmas sobre el terreno<\/h4>\n<p>Solo se comprobar\u00e1 el correcto funcionamiento de los contactos de alarma (es decir, los contactos de alarma) cuando se produzca una aver\u00eda real (por ejemplo, al pulsar el bot\u00f3n de prueba del RCBO o al simular un cortocircuito). Tambi\u00e9n se comprobar\u00e1 su correcto funcionamiento cuando el interruptor se abra manualmente, sin provocar una falsa alarma, lo que ayudar\u00e1 a eliminar el desperdicio de recursos que supone la reparaci\u00f3n de falsas alarmas, las cuales generan incertidumbre entre los clientes sobre la fiabilidad de sus equipos.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Ventaja 2: Detecta la oxidaci\u00f3n por contacto antes de que provoque un fallo<\/h4>\n<p>Las devoluciones y las llamadas de servicio resultan costosas para los fabricantes; una medici\u00f3n elevada de la resistencia de contacto (50 m\u03a9) provoca la intermitencia o la p\u00e9rdida de la se\u00f1al. Los fabricantes detectan esta se\u00f1al intermitente y reparan el equipo antes de que sea devuelto al centro de servicio.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Ventaja 3: Garantiza la integridad del aislamiento para mayor seguridad<\/h4>\n<p>La prueba de rigidez diel\u00e9ctrica se lleva a cabo aplicando la alta tensi\u00f3n especificada (1500 V o 2000 V) entre los terminales y comprobando si se produce alg\u00fan fallo en el aislamiento, as\u00ed como si hay corriente de fuga. Por ello, la prueba de rigidez diel\u00e9ctrica es especialmente importante para los dispositivos que cuentan con contactos auxiliares que se conectan a PLC de baja tensi\u00f3n o a circuitos de control, ya que cualquier fallo del material aislante podr\u00eda provocar da\u00f1os en equipos de automatizaci\u00f3n muy costosos o suponer un riesgo de descarga el\u00e9ctrica.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Ventaja 4: Pruebas r\u00e1pidas y repetibles<\/h4>\n<p>Gracias a la automatizaci\u00f3n de la secuencia de pruebas l\u00f3gicas en modo dual, las pruebas de banco permiten ahora completar la validaci\u00f3n y el ensayo de un m\u00f3dulo de contacto auxiliar en menos de 30 segundos, frente a los varios minutos que requir\u00edan las pruebas manuales con mult\u00edmetro. Un solo operario puede probar cientos de estos m\u00f3dulos durante un turno y los resultados repetibles ser\u00e1n coherentes con la precisi\u00f3n 100%.<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-partners\">\n        <span class=\"bl-pdp-partners-title\">Con la confianza de los l\u00edderes de la industria.<\/span><\/p>\n<div class=\"bl-pdp-partners-list\">\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738413289.webp\" alt=\"TEJIDO\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594739263598.webp\" alt=\"DELIXI\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594739675877.webp\" alt=\"EKF\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594741141751.webp\" alt=\"KRIPAL\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738593989.webp\" alt=\"HPL\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738101609.webp\" alt=\"CHAC\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738124777.webp\" alt=\"Schneider\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738797907.webp\" alt=\"GRUPO IEK\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738812289.webp\" alt=\"SUNIR\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738411369.webp\" alt=\"Bevone\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738389707.webp\" alt=\"Weg\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738361034.webp\" alt=\"HUYU\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738416677.webp\" alt=\"RAAD\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738314557.webp\" alt=\"WALTONE\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738445639.webp\" alt=\"HAVELLS\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738720809.webp\" alt=\"C&amp;S el\u00e9ctrico\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-case\">\n<h3>\u00c9xito del cliente: c\u00f3mo evitar las devoluciones por falsas alarmas<\/h3>\n<p>Una empresa consolidada del sector de los RCBO ten\u00eda 5% de sus m\u00f3dulos de contacto de campo devueltos, y estos generaban falsas alarmas cuando se abr\u00eda el sistema manualmente. La empresa investig\u00f3 el motivo de estos problemas y descubri\u00f3 que la causa era la falta de coherencia en las pruebas l\u00f3gicas realizadas durante la producci\u00f3n. Posteriormente, introdujo un banco de pruebas de contactos auxiliares y de se\u00f1al con pruebas automatizadas en modo dual para la verificaci\u00f3n l\u00f3gica y logr\u00f3:<\/p>\n<div class=\"bl-pdp-case-stats\">\n<div class=\"bl-pdp-case-stat\"><strong>0.1%<\/strong> Vuelven las falsas alarmas (por debajo de 5%)<\/div>\n<div class=\"bl-pdp-case-stat\"><strong>100%<\/strong> Cobertura de las pruebas de resistencia l\u00f3gica y de contacto<\/div>\n<div class=\"bl-pdp-case-stat\"><strong>$200k\/a\u00f1o<\/strong> Ahorro en costes de garant\u00eda y de servicio t\u00e9cnico sobre el terreno<\/div>\n<\/p><\/div>\n<p style=\"margin-top: 12px; font-size: 14px;\">El banco de pruebas amortiz\u00f3 su coste en los cuatro meses siguientes a su adquisici\u00f3n, adem\u00e1s de convertirse en la principal estaci\u00f3n de pruebas para todos los contactos auxiliares fabricados.<\/p>\n<\/p><\/div>\n<h2>Aplicaciones: d\u00f3nde aporta este banco el mayor valor a\u00f1adido<\/h2>\n<div class=\"bl-pdp-feature\">\n<div class=\"bl-pdp-feature-list\">\n<div class=\"bl-pdp-feature-item\"><strong>Fabricaci\u00f3n de contactos auxiliares<\/strong> \u2013 Pruebas finales de control de calidad de la l\u00f3gica de contacto, la resistencia y el aislamiento<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>L\u00edneas de montaje de RCBO \/ MCB<\/strong> \u2013 Verificaci\u00f3n en l\u00ednea de los contactos auxiliares y de se\u00f1al montados<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Inspecci\u00f3n entrante<\/strong> \u2013 Pruebas de los m\u00f3dulos de contactos auxiliares adquiridos a los proveedores<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Validaci\u00f3n de I+D<\/strong> \u2013 Caracterizaci\u00f3n de nuevos dise\u00f1os de contactos auxiliares<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<h2>Ingenier\u00eda y entrega a medida<\/h2>\n<div class=\"bl-pdp-steps\">\n<div class=\"bl-pdp-step\"><strong>1. An\u00e1lisis de muestras por contacto<\/strong> 7-15 d\u00edas \u00b7 m\u00f3dulo de contactos auxiliares\/de se\u00f1al, RCBO\/MCB para su instalaci\u00f3n<\/div>\n<div class=\"bl-pdp-step\"><strong>2. Programaci\u00f3n de fixture y l\u00f3gica<\/strong> 10-20 d\u00edas \u00b7 dispositivo de fijaci\u00f3n universal, secuencia de prueba de modo dual<\/div>\n<div class=\"bl-pdp-step\"><strong>3. Fabricaci\u00f3n y montaje<\/strong> 30-45 d\u00edas<\/div>\n<div class=\"bl-pdp-step\"><strong>4. Pre-FAT<\/strong> En la f\u00e1brica de Benlong<\/div>\n<div class=\"bl-pdp-step\"><strong>5. Instalaci\u00f3n y formaci\u00f3n<\/strong> Entre 2 y 3 d\u00edas en el lugar<\/div>\n<div class=\"bl-pdp-step\"><strong>6. Examen final del SAT<\/strong> 2-3 d\u00edas \u00b7 informe de aceptaci\u00f3n<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-cta\">\n<h2>Solicita un presupuesto personalizado para un banco de pruebas de contactos auxiliares<\/h2>\n<p>Por favor, facil\u00edtenos las especificaciones de ensayo de los contactos auxiliares y de se\u00f1al, as\u00ed como muestras. Dise\u00f1aremos un banco de pruebas que incluya ensayos de doble modo: resistencia de contacto (nivel bajo) y de alta tensi\u00f3n, y calcularemos el retorno de la inversi\u00f3n (ROI).<\/p>\n<p>        <a class=\"bl-pdp-btn\" href=\"\/es\/contact\/\">Consulta ahora<\/a><\/p>\n<p class=\"bl-pdp-footnote\">WhatsApp: +86 150 5837 0007 | Correo electr\u00f3nico: xsb@benlongkj.cn | Soporte en ingl\u00e9s y chino<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-two-col\">\n<div class=\"bl-pdp-col-main\">\n<h3>\u00bfPor qu\u00e9 elegir Benlong para los bancos de pruebas de contacto?<\/h3>\n<ul>\n<li>M\u00e1s de 15 a\u00f1os dise\u00f1ando <strong>equipos de prueba de contacto<\/strong> para componentes el\u00e9ctricos de baja tensi\u00f3n<\/li>\n<li>Prueba l\u00f3gica de modo dual contrastada (auxiliar frente a alarma): elimina las falsas alarmas<\/li>\n<li>Medici\u00f3n integrada de la resistencia de contacto (precisi\u00f3n de \u00b11%) y pruebas de alta tensi\u00f3n<\/li>\n<li>Soporte universal para varios modelos de contactos auxiliares<\/li>\n<li>Soporte t\u00e9cnico y de repuestos a nivel mundial<\/li>\n<\/ul><\/div>\n<div class=\"bl-pdp-col-side\">\n<h3>El banco est\u00e1ndar incluye<\/h3>\n<p>Dispositivo universal de contacto de se\u00f1al auxiliar, con accionamiento autom\u00e1tico de la palanca en modo auxiliar, simulador de disparo por fallo y\/o actuador del bot\u00f3n de prueba para la inyecci\u00f3n de cortocircuito. Microohm\u00edmetro para la resistencia de contacto. Comprobador de CA de alta tensi\u00f3n para 2000 V. PLC con HMI. Luces indicadoras de \u00abOK\u00bb\/\u00abNG\u00bb. Carcasa de seguridad. Manuales de usuario. Certificados de calibraci\u00f3n. 1 a\u00f1o de garant\u00eda.<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-internal-links\">\n        <span class=\"bl-pdp-internal-links-title\">Soluciones relacionadas<\/span><\/p>\n<div class=\"bl-pdp-links-list\">\n            <a href=\"https:\/\/benlongkj.com\/es\/rcbo-semi-automatic-comprehensive-test-bench-product\/\">Banco de pruebas integral semiautom\u00e1tico para RCBO<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/es\/mcb-automatic-testing-line\/\">L\u00ednea de prueba autom\u00e1tica de MCB<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/es\/ac-contactor-comprehensive-test-machine-product\/\">M\u00e1quina de prueba integral para contactores de CA<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/es\/mccb-semi-automatic-high-voltage-test-bench-product\/\">Banco de pruebas semiautom\u00e1tico de alta tensi\u00f3n para interruptores autom\u00e1ticos de caja moldeada (MCCB)<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/es\/load-isolation-switch-automatic-testing-line-product\/\">L\u00ednea de prueba del interruptor de aislamiento de carga<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/es\/mcb-handle-link-automatic-assembly-machine-product\/\">M\u00e1quina de ensamblaje de enlaces de manija MCB<\/a>\n        <\/div>\n<\/p><\/div>\n<h2>Preguntas frecuentes<\/h2>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">\u00bfCu\u00e1l es la diferencia entre el modo auxiliar y el modo de alarma?<\/div>\n<p>Los contactos para el modo auxiliar cambian de estado cada vez que se acciona la palanca del interruptor autom\u00e1tico, ya sea mediante accionamiento manual (como la apertura o el cierre) o como indicaci\u00f3n remota de la posici\u00f3n; no cambian de estado debido a un evento de disparo (fallo), como una sobrecarga o un cortocircuito. Los contactos utilizados en el modo de alarma indican el estado del interruptor tras un disparo provocado por una aver\u00eda. El objetivo de probar el banco en ambos modos es verificar el funcionamiento previsto de los contactos.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">\u00bfC\u00f3mo simula el banco de pruebas una desconexi\u00f3n por fallo para las pruebas en modo de alarma?<\/div>\n<p>En el caso de los RCBO, no es necesario crear el circuito de prueba, ya que el banco de pruebas realiza la prueba autom\u00e1ticamente al pulsar el bot\u00f3n T (prueba) situado en la tapa del interruptor. En el caso de los MCB, el banco de pruebas puede inyectar una corriente de cortocircuito ajustable para crear una envolvente que permita el funcionamiento del mecanismo de disparo magn\u00e9tico; alternativamente, el uso de un actuador mec\u00e1nico para disparar el mecanismo tambi\u00e9n requerir\u00e1 la creaci\u00f3n de un circuito de prueba. El cambio de estado de los contactos se verifica en tiempo real.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">\u00bfCu\u00e1l es la resistencia de contacto admisible para los contactos auxiliares?<\/div>\n<p>La norma IEC 60947-5-1 recomienda una resistencia inferior a 50 m\u03a9 para los contactos nuevos. El banco de pruebas permite establecer un l\u00edmite m\u00e1ximo programable (por ejemplo, 50 m\u03a9). Una resistencia m\u00e1s elevada indica oxidaci\u00f3n, contaminaci\u00f3n o una presi\u00f3n de contacto insuficiente, lo que puede provocar una transmisi\u00f3n intermitente de la se\u00f1al.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">\u00bfAdmite el banco diferentes configuraciones de pines de contacto (por ejemplo, 11-12-14)?<\/div>\n<p>S\u00ed. El soporte universal cuenta con sondas que se pueden ajustar para adaptarse a distintas configuraciones de pines. Una vez seleccionada la receta del producto, la secuencia de prueba determinar\u00e1 autom\u00e1ticamente la configuraci\u00f3n de pines.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">\u00bfPuede el banco de pruebas comprobar simult\u00e1neamente los contactos normalmente abiertos y los normalmente cerrados?<\/div>\n<p>El banco de pruebas comprueba la continuidad de los contactos NO y NC a lo largo de toda la secuencia de prueba. En la prueba auxiliar, debe haber continuidad a trav\u00e9s del contacto NO mientras el interruptor se encuentra en la posici\u00f3n ON y a trav\u00e9s del contacto NC mientras el interruptor se encuentra en la posici\u00f3n OFF. El modo de alarma comprueba que solo el contacto adecuado cambie de estado cuando se produzca una desconexi\u00f3n por fallo.<\/p>\n<\/p><\/div>\n<div style=\"margin: 32px 0 16px; font-size: 12px; text-align: center; border-top: 1px solid #e9edf2; padding-top: 16px; color: #5f7d9c;\">\n        Todas las especificaciones est\u00e1n sujetas a acuerdo t\u00e9cnico definitivo. Benlong Automation: soluciones de prueba de contactos auxiliares y de se\u00f1al para fabricantes de RCBO y MCB.\n    <\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Banco de pruebas de contactos auxiliares y de se\u00f1al para RCBO\/MCB. Comprueba la l\u00f3gica de doble modo (auxiliar y de alarma), la resistencia de los contactos (&lt;50 m\u03a9) y rigidez diel\u00e9ctrica (1500 V\/2000 V). Elimina las falsas alarmas, detecta la oxidaci\u00f3n y garantiza la integridad del aislamiento. Ideal para laboratorios de control de calidad y l\u00edneas de producci\u00f3n. Cumple con la norma IEC 60947\u20115\u20111.\n<\/p>","protected":false},"featured_media":26,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[20],"product_tag":[],"class_list":["post-27","product","type-product","status-publish","has-post-thumbnail","product_cat-test-bench-project","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/benlongkj.com\/es\/wp-json\/wp\/v2\/product\/27","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/benlongkj.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/benlongkj.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/es\/wp-json\/wp\/v2\/comments?post=27"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/es\/wp-json\/wp\/v2\/media\/26"}],"wp:attachment":[{"href":"https:\/\/benlongkj.com\/es\/wp-json\/wp\/v2\/media?parent=27"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/benlongkj.com\/es\/wp-json\/wp\/v2\/product_brand?post=27"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/benlongkj.com\/es\/wp-json\/wp\/v2\/product_cat?post=27"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/benlongkj.com\/es\/wp-json\/wp\/v2\/product_tag?post=27"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}