{"id":67,"date":"2026-06-01T10:37:59","date_gmt":"2026-06-01T10:37:59","guid":{"rendered":"https:\/\/khkrh7q1ur.wpdns.site\/product\/electric-meter-aging-test-bench\/"},"modified":"2026-06-09T23:01:48","modified_gmt":"2026-06-09T23:01:48","slug":"electric-meter-aging-test-bench-product","status":"publish","type":"product","link":"https:\/\/benlongkj.com\/de\/produkt\/electric-meter-aging-test-bench-product\/","title":{"rendered":"Alterungspr\u00fcfstand f\u00fcr Stromz\u00e4hler"},"content":{"rendered":"<div class=\"bl-pdp-wrapper\">\n<div class=\"bl-pdp-split\">\n<div class=\"bl-pdp-split-text\">\n<div class=\"bl-pdp-badge\">IEC\/ANSI \u00b7 Dauerhafter Betrieb rund um die Uhr<\/div>\n<h1>Alterungspr\u00fcfstand f\u00fcr dreiphasige Stromz\u00e4hler zur Untersuchung der Zuverl\u00e4ssigkeit intelligenter Stromz\u00e4hler<\/h1>\n<p>Dieses zuverl\u00e4ssige elektrische Testger\u00e4t wurde speziell f\u00fcr die Pr\u00fcfung Tausender dreiphasiger Multifunktions-Smartmeter hinsichtlich Qualit\u00e4t und Langlebigkeit in Anwendungen mit hohem Durchsatz entwickelt. Das Testger\u00e4t nutzt das Pr\u00e4zisionsnetzteil ZN-D3000, um konstante Spannungs- und Stromlasten bereitzustellen und so den Langzeiteinsatz im Feld zu simulieren. Dadurch werden Messgenauigkeit und strukturelle Integrit\u00e4t auch unter statischer Last gew\u00e4hrleistet. Dank modularer Steckverbinder am vertikalen Z\u00e4hlergestell unterst\u00fctzt das Testger\u00e4t mehrere simultane Alterungsprozesse und bietet somit eine extrem hohe Testdichte.<\/p>\n<p>Im Rahmen des kontinuierlichen Messprozesses erfasst das System \u00c4nderungen wichtiger Indikatoren wie Durchschlagsfestigkeit, Messwertakkumulation (Gehtest) und Stabilit\u00e4t des Kommunikationsprotokolls (IEC 62056-21, DLMS\/COSEM). \u00dcber die Steuerungsschnittstelle lassen sich Phasenwinkel, Oberwellenverzerrung und Lastpegel pr\u00e4ziser einstellen. Echtzeit-Datenprotokollierung und automatischer Abschaltschutz gew\u00e4hrleisten sicheres Testen und die Speicherung historischer Daten im 24\/7-Betrieb. Dieses robuste Testverfahren erf\u00fcllt oder \u00fcbertrifft internationale Pr\u00fcfnormen (IEC, ANSI) und garantiert eine Lebensdauer von 15 Jahren unter extremen Bedingungen. Durch die Reduzierung der Ausfallrate elektronischer Ger\u00e4te in der Anfangsphase tr\u00e4gt der Pr\u00fcfstand zu langfristiger Abrechnungsgenauigkeit bei.<\/p>\n<p><span style=\"color: #2872fa; font-weight: 500;\">Standardlieferzeit: 45\u201360 Tage | Netzteil ZN-D3000 | Vertikales Hochdichte-Rack<\/span><\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-split-media\">\n            <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Electric-meter-aging-test-bench-scaled.webp\" alt=\"Alterungspr\u00fcfstand f\u00fcr Stromz\u00e4hler\"><\/p>\n<div style=\"font-size: 11px; margin-top: 8px;\">Dreiphasen-Z\u00e4hler-Alterungspr\u00fcfstand (tats\u00e4chliches Produkt)<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-definition\">\n<h2>Was ist ein Alterungspr\u00fcfstand f\u00fcr elektrische Stromz\u00e4hler?<\/h2>\n<p>Ein Alterungspr\u00fcfstand f\u00fcr Stromz\u00e4hler dient der beschleunigten Lebensdauerpr\u00fcfung (Burn-in-Test) von ein- und dreiphasigen Energiez\u00e4hlern unter definierten Umgebungsbedingungen (Raumtemperatur). Dabei werden kontrollierte Spannungen und Str\u00f6me angewendet. Durch Anlegen der Nennspannung und des Nennstroms \u00fcber einen l\u00e4ngeren Zeitraum (Stunden bis Tage) lassen sich fr\u00fchzeitige Ausf\u00e4lle elektronischer Bauteile, L\u00f6tstellen und mechanischer Teile erkennen. Der Pr\u00fcfstand besteht aus einem hochpr\u00e4zisen programmierbaren Netzteil (z. B. ZN-D3000), einem hochdichten Z\u00e4hler-Montagegestell mit modularen Steckverbindern und einer Datenerfassungssoftware. Er erfasst Daten f\u00fcr Funktionstests (z. B. Z\u00e4hlerstandsakkumulationen), Kommunikationsstabilit\u00e4t und Durchschlagsfestigkeit w\u00e4hrend des Alterungszyklus des Z\u00e4hlers. Das Alterungspr\u00fcfstandsystem tr\u00e4gt au\u00dferdem dazu bei, die Ausfallrate von Smart Metern in der Anfangsphase zu senken und die Einhaltung von IEC 62053-11\/22, ANSI C12 oder kundenspezifischen Zuverl\u00e4ssigkeitsanforderungen sicherzustellen. Da es sich um eine kundenspezifische L\u00f6sung handelt, wird dieses System auf Ihren spezifischen Z\u00e4hlerformfaktor, die Anzahl der Messpositionen (z. B. 24, 48, 96 Meter) und die Kommunikationsprotokolle zugeschnitten.<\/p>\n<div class=\"bl-pdp-feature-grid\">\n<div class=\"bl-pdp-feature-card\">\n                <strong>Pr\u00e4zisionsstromquelle ZN-D3000<\/strong><br \/>\n                Synchronisierte dreiphasige Spannung und Stromst\u00e4rke, einstellbare Amplitude, Phase und Oberschwingungen.\n            <\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Hochdichtes vertikales Regal<\/strong><br \/>\n                Modulare Steckverbinder f\u00fcr die gleichzeitige Pr\u00fcfung mehrerer Messger\u00e4te (24\u201396 Positionen).\n            <\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Echtzeit\u00fcberwachung<\/strong><br \/>\n                Durchschlagsfestigkeit, Registerakkumulation, Stabilit\u00e4t des Kommunikationsprotokolls.\n            <\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Automatischer Ausl\u00f6seschutz und Datenprotokollierung<\/strong><br \/>\n                \u00dcberlast- und \u00dcbertemperaturschutz; CSV\/MES-Export zur R\u00fcckverfolgbarkeit.\n            <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery\">\n<h2>Testfunktionen und Systemkomponenten<\/h2>\n<div class=\"bl-pdp-gallery-grid\">\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Intelligence-Visibility.webp\" alt=\"Informationstransparenz \u2013 Echtzeit\u00fcberwachung\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Intelligenz und Transparenz<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Efficiency-Sustainability.webp\" alt=\"Effizienz und Nachhaltigkeit \u2013 Energieeinsparung\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Effizienz und Nachhaltigkeit<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Design-Integration.webp\" alt=\"Designintegration \u2013 modulare Konstruktion\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Design &amp; Integration<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Safety-Reliability.webp\" alt=\"Sicherheit und Zuverl\u00e4ssigkeit \u2013 strenge Tests\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Sicherheit und Zuverl\u00e4ssigkeit<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<h2>Technische Spezifikationen<\/h2>\n<div class=\"bl-pdp-summary\">Dreiphasen-Z\u00e4hleralterungspr\u00fcfstand mit Pr\u00e4zisionsquelle ZN-D3000. Hochdichtes Rack, Echtzeit\u00fcberwachung (Dielektrikum, Z\u00e4hlerstand, Kommunikation), automatischer Schutz, Datenprotokollierung.<\/div>\n<div class=\"bl-pdp-table-wrap\">\n<table class=\"bl-pdp-table\">\n<tbody>\n<tr>\n<th style=\"width: 35%;\">Stromversorgungsmodell<\/th>\n<td>ZN\u2011D3000 (programmierbarer Drehstromgenerator)<\/td>\n<\/tr>\n<tr>\n<th>Spannungsausgangsbereich<\/th>\n<td>0 \u2013 480 V Wechselstrom (Phase\u2010Neutralleiter), einstellbar\u2013\n                <\/td>\n<\/tr>\n<tr>\n                <\/tr>\n<tr>\n<th>Aktueller Ausgangsbereich<\/th>\n<td>0 \u2013 120 A pro Phase, programmierbar\u2013\n                <\/td>\n<\/tr>\n<tr>\n<th>Frequenzbereich<\/th>\n<td>45 \u2013 65 Hz, Genauigkeit \u00b10,01 Hz\u2013\n                <\/td>\n<\/tr>\n<tr>\n<th>Harmonische Simulation<\/th>\n<td>2. bis 21. Ordnung, programmierbare Amplitude\/Phase\u2013\n                <\/td>\n<\/tr>\n<tr>\n<th>Anzahl der Messpositionen<\/th>\n<td>Standardm\u00e4\u00dfig 24, 48 oder 96 (anpassbar)\u2013\n                <\/td>\n<\/tr>\n<tr>\n                <\/tr>\n<tr>\n<th>Kommunikationsprotokolle<\/th>\n<td>RS485 (Modbus, DLMS\/COSEM), optischer Port, Impulsausgang\u2013\n                <\/td>\n<\/tr>\n<tr>\n<th>\u00dcberwachungsparameter<\/th>\n<td>Registerakkumulation (Gehtest), Durchschlagsfestigkeit, Kommunikationsfehler, Temperatur\u2013\n                <\/td>\n<\/tr>\n<tr>\n<th>Schutzfunktionen<\/th>\n<td>\u00dcberlastung, \u00dcbertemperatur, Kurzschluss, automatische Abschaltung\n                <\/td>\n<\/tr>\n<tr>\n<th>Stromversorgung<\/th>\n<td>380 V \u00b1101 TPS 3T 50 Hz (Hauptanschluss) | Steuerung: 220 V \u2013\n                <\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<h2>Technische Kernvorteile<\/h2>\n<div class=\"bl-pdp-grid\">\n<div class=\"bl-pdp-card\">\n<h4>Hochdichte Parallelalterung verk\u00fcrzt die Zykluszeit<\/h4>\n<p>            Mit bis zu 96 Messpositionen beschleunigt der Pr\u00fcfstand die Einbrenntests erheblich. Jede Position wird unabh\u00e4ngig \u00fcberwacht, wodurch eine Chargenqualifizierung ohne Durchsatzreduzierung m\u00f6glich ist.\n        <\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Pr\u00e4zisionsquelle ZN\u2011D3000 f\u00fcr realistische Gittersimulation<\/h4>\n<p>            Die integrierte Stromquelle liefert synchronisierte dreiphasige Spannung und Strom mit einstellbaren Phasenwinkeln, Oberschwingungen und Lastpegeln. Dies simuliert reale Netzst\u00f6rungen (Spannungseinbr\u00fcche, Oberschwingungen), die die Z\u00e4hlerleistung beeintr\u00e4chtigen.\n        <\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Umfassende Kommunikations- und Register\u00fcberwachung<\/h4>\n<p>            Der Pr\u00fcfstand liest w\u00e4hrend des Alterungszyklus Z\u00e4hlerst\u00e4nde \u00fcber RS485 oder eine optische Schnittstelle aus und \u00fcberpr\u00fcft so, ob die Akkumulation auch unter Dauerbelastung korrekt bleibt. Kommunikationsfehler werden zur Analyse der Protokollstabilit\u00e4t protokolliert.\n        <\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Automatische Sicherheit und Datenr\u00fcckverfolgbarkeit<\/h4>\n<p>            Der Echtzeit-Ausl\u00f6seschutz verhindert Sch\u00e4den durch Z\u00e4hlerausf\u00e4lle. Alle Testdaten (Spannungs-\/Stromprotokolle, Z\u00e4hlerwerte, Fehlerereignisse) werden gespeichert und k\u00f6nnen in MES oder als CSV-Datei exportiert werden, wodurch die vollst\u00e4ndige R\u00fcckverfolgbarkeit f\u00fcr ISO-17025-Audits gew\u00e4hrleistet ist.\n        <\/p><\/div>\n<\/p><\/div>\n<p>    <!-- \u5408\u4f5c\u4f19\u4f34\u6a21\u5757 --><\/p>\n<div class=\"bl-pdp-partners\">\n        <span class=\"bl-pdp-partners-title\">Von Branchenf\u00fchrern gesch\u00e4tzt<\/span><\/p>\n<div class=\"bl-pdp-partners-list\">\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738413289.webp\" alt=\"ABB\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594739263598.webp\" alt=\"DELIXI\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594739675877.webp\" alt=\"EKF\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594741141751.webp\" alt=\"KRIPAL\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738593989.webp\" alt=\"HPL\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738101609.webp\" alt=\"CHAC\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738124777.webp\" alt=\"Schneider\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738797907.webp\" alt=\"IEK-GRUPPE\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738812289.webp\" alt=\"SUNIR\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738411369.webp\" alt=\"Bevone\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738389707.webp\" alt=\"Weg\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738361034.webp\" alt=\"HUYU\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738416677.webp\" alt=\"RAAD\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738314557.webp\" alt=\"WALTONE\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738445639.webp\" alt=\"Havells\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738720809.webp\" alt=\"C&amp;S Electric\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-case\">\n<h3>Kundenerfolgsgeschichte \u2013 Hersteller von intelligenten Stromz\u00e4hlern<\/h3>\n<p>Ein f\u00fchrender Hersteller von intelligenten Stromz\u00e4hlern forderte eine Reduzierung der Ausfallrate seiner Drehstromz\u00e4hler im Feld, da elektronische Bauteile fr\u00fchzeitig ausfielen (sogenannte \u201eKindheitsausf\u00e4lle\u201c). Um diesem Bedarf gerecht zu werden, lieferte Benlong einen Alterungspr\u00fcfstand mit 96 Messpl\u00e4tzen, ausgestattet mit einem Netzteil ZN-D3000 und Echtzeit-Register\u00fcberwachung. Sechs Monate nach der Installation dieser Pr\u00fcfst\u00e4nde:<\/p>\n<div class=\"bl-pdp-case-stats\">\n<div class=\"bl-pdp-case-stat\"><strong>80%<\/strong> Reduzierung von fr\u00fchen Feldausf\u00e4llen<\/div>\n<div class=\"bl-pdp-case-stat\"><strong>96 Meter<\/strong> Gleichzeitig gealtert (24\/7)<\/div>\n<div class=\"bl-pdp-case-stat\"><strong>100%<\/strong> R\u00fcckverfolgbarkeit bei Versorgungspr\u00fcfungen<\/div>\n<\/p><\/div>\n<p style=\"margin-top: 12px; font-size: 14px;\">Innerhalb von weniger als 10 Monaten nach der Installation konnte der Kunde von den Kosteneinsparungen der Bank profitieren, indem er einen bedeutenden Versorgungsvertrag abschloss, der die Einhaltung der Norm IEC 62053-22 erforderte.<\/p>\n<\/p><\/div>\n<h2>Anwendungen und Integration<\/h2>\n<div class=\"bl-pdp-feature\">\n<div class=\"bl-pdp-feature-list\">\n<div class=\"bl-pdp-feature-item\"><strong>Herstellung intelligenter Z\u00e4hler<\/strong> \u2013 Einbrenntests f\u00fcr Einphasen- und Dreiphasenz\u00e4hler<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Labore f\u00fcr die Messung von Versorgungsleistungen<\/strong> \u2013 Dauerpr\u00fcfung f\u00fcr die Z\u00e4hlerzertifizierung<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Qualit\u00e4tssicherungsabteilungen<\/strong> \u2013 Routinem\u00e4\u00dfige Zuverl\u00e4ssigkeitspr\u00fcfung<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>F&amp;E-Validierung<\/strong> \u2013 Stresstests f\u00fcr neue Z\u00e4hlerdesigns<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<h2>Kundenspezifische Entwicklung &amp; Lieferung<\/h2>\n<div class=\"bl-pdp-steps\">\n<div class=\"bl-pdp-step\"><strong>1. Z\u00e4hlerspezifikation &amp; Rack-Design<\/strong> 15-30 Tage \u00b7 Abmessungen des Messger\u00e4ts, Anzahl der Positionen<\/div>\n<div class=\"bl-pdp-step\"><strong>2. Stromversorgung und Softwarekonfiguration<\/strong> 15\u201325 Tage \u00b7 ZN-D3000-Integration, Kommunikationseinrichtung<\/div>\n<div class=\"bl-pdp-step\"><strong>3. Fertigung<\/strong> 45-60 Tage<\/div>\n<div class=\"bl-pdp-step\"><strong>4. Pre-FAT<\/strong> Im Werk Benlong<\/div>\n<div class=\"bl-pdp-step\"><strong>5. Installation und Schulung<\/strong> Lieferung vor Ort innerhalb von 5\u20137 Tagen<\/div>\n<div class=\"bl-pdp-step\"><strong>6. Abschlie\u00dfender SAT<\/strong> 5\u20137 Tage \u00b7 Abnahmeprotokoll<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-cta\">\n<h2>Fordern Sie ein individuelles Angebot f\u00fcr einen Alterungspr\u00fcfstand f\u00fcr Stromz\u00e4hler an.<\/h2>\n<p>Teilen Sie uns bitte die Spezifikationen Ihres Messger\u00e4ts, die Anzahl der Testpositionen und das Kommunikationsprotokoll mit. Unsere Ingenieure entwickeln daraufhin f\u00fcr Sie einen ma\u00dfgeschneiderten Alterungspr\u00fcfstand mit unserer Stromversorgung ZN-D3000, umfassender Datenprotokollierung und einem detaillierten ROI-Bericht.<\/p>\n<p>        <a class=\"bl-pdp-btn\" href=\"\/de\/contact\/\">Jetzt anfragen<\/a><\/p>\n<p class=\"bl-pdp-footnote\">WhatsApp: +86 150 5837 0007 | E-Mail: xsb@benlongkj.cn | Support in Englisch und Chinesisch<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-two-col\">\n<div class=\"bl-pdp-col-main\">\n<h3>Warum sollten Sie sich f\u00fcr Benlong-Z\u00e4hleralterungspr\u00fcfst\u00e4nde entscheiden?<\/h3>\n<ul>\n<li>Mehr als 15 Jahre Erfahrung im Designbereich <strong>Pr\u00fcfger\u00e4te f\u00fcr Energiez\u00e4hler<\/strong> f\u00fcr Energieversorger und Hersteller<\/li>\n<li>Bew\u00e4hrte Integration der Pr\u00e4zisionsstromquelle ZN-D3000<\/li>\n<li>Vertikale Hochdichte-Racks (bis zu 96 Positionen)<\/li>\n<li>Echtzeit-Register\u00fcberwachung und Kommunikationstests<\/li>\n<li>Vollst\u00e4ndige R\u00fcckverfolgbarkeit \u2013 Datenprotokollierung bis MES, IEC\/ANSI-Konformit\u00e4t<\/li>\n<\/ul><\/div>\n<div class=\"bl-pdp-col-side\">\n<h3>Eine typische ma\u00dfgefertigte Werkbank umfasst:<\/h3>\n<p>Dreiphasen-Programmierbare Stromquelle \u2013 ZN-D3000, hochdichtes Messgestell (kann nach jedem Design gebaut werden), modulare Testanschl\u00fcsse, SPS-Steuerung\/HMI, Live-Datenprotokollierungssoftware, RS485 + optische Port-Kommunikationsmodule, \u00dcberlast- + \u00dcbertemperaturschutz, Kalibrierungszertifikat, Installation + Schulung, 1 Jahr Garantie.<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<p>    <!-- \u5185\u90e8\u94fe\u63a5 --><\/p>\n<div class=\"bl-pdp-internal-links\">\n        <span class=\"bl-pdp-internal-links-title\">Verwandte L\u00f6sungen<\/span><\/p>\n<div class=\"bl-pdp-links-list\">\n            <a href=\"https:\/\/benlongkj.com\/de\/three-phase-electric-meter-automatic-production-line-product\/\">Dreiphasen-Z\u00e4hler-Produktionslinie<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/de\/single-phase-meter-automatic-production-line-product\/\">Produktionslinie f\u00fcr Einphasenz\u00e4hler<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/de\/electric-meter-manual-calibration-bench-product\/\">Pr\u00fcfstand zur manuellen Kalibrierung von Stromz\u00e4hlern<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/de\/meter-communication-test-bench-product\/\">Pr\u00fcfstand f\u00fcr Z\u00e4hlerkommunikation<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/de\/meter-pcba-automatic-insertion-machine-product\/\">Meter PCBA Best\u00fcckungsmaschine<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/de\/indicator-light-automatic-production-line-product\/\">Produktionslinie f\u00fcr Kontrollleuchten<\/a>\n        <\/div>\n<\/p><\/div>\n<h2>H\u00e4ufig gestellte Fragen<\/h2>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Welchen Zweck hat die Alterungspr\u00fcfung (Einbrennpr\u00fcfung) von Stromz\u00e4hlern?<\/div>\n<p>Alterungstests, die auf einer festgelegten Spannung und Stromst\u00e4rke basieren, werden \u00fcber einen l\u00e4ngeren Zeitraum, beispielsweise 24 bis 72 Stunden, an Messger\u00e4ten durchgef\u00fchrt, um elektronische Bauteile (wie Kondensatoren, Netzteile oder L\u00f6tverbindungen) zu identifizieren, die im Feld anf\u00e4llig f\u00fcr Ausf\u00e4lle sind. Dadurch wird die Ausfallrate in der Anfangsphase reduziert und eine lange Nutzungsdauer neuer Produkte gew\u00e4hrleistet.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Wie genau misst der Pr\u00fcfstandmonitor die Alterungsgenauigkeit?<\/div>\n<p>In regelm\u00e4\u00dfigen Abst\u00e4nden (z. B. st\u00fcndlich) liest der Pr\u00fcfstand Z\u00e4hlerst\u00e4nde \u00fcber eine RS485- oder optische Schnittstelle aus und berechnet einen Akkumulator f\u00fcr diese Z\u00e4hlerst\u00e4nde, um diesen mit einem Referenzwert auf Drift oder Kommunikationsfehler zu vergleichen (bekannt als \u201cWalking Test\u201d).<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Kann der Pr\u00fcfstand sowohl Einphasen- als auch Dreiphasenz\u00e4hler testen?<\/div>\n<p>Absolut! Es werden sowohl einphasige als auch dreiphasige Z\u00e4hlerkonfigurationen verf\u00fcgbar sein; dies umfasst einphasige Anschlusskonfigurationen mit einphasigem Stromanschluss und dreiphasige Anschlusskonfigurationen mit der dreiphasigen ZN-D3000-Quellenkonfiguration. Backup-Racks k\u00f6nnen erstellt werden, ben\u00f6tigen jedoch eine separate Verkabelung.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Welche Kommunikationsprotokolle werden unterst\u00fctzt?<\/div>\n<p>Das Ger\u00e4t kann \u00fcber RS485 (Modbus RTU, DLMS\/COSEM), einen optischen Anschluss (IEC 62056-21), Impulsausg\u00e4nge oder optional drahtlos (LoRa, NB-IoT) verbunden werden. Kundenspezifische Integrationen sind m\u00f6glich.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Welche Sicherheitsvorkehrungen sch\u00fctzen die Bank und die Messger\u00e4te?<\/div>\n<p>Jeder Z\u00e4hlerplatz verf\u00fcgt \u00fcber einen individuellen Leitungsschutzschalter oder eine Sicherung zur Fehlerisolierung sowie \u00fcber \u00dcberlastschutz (Strombegrenzung), \u00dcbertemperaturabschaltung, Kurzschlusserkennung und Erdschlussschutz.<\/p>\n<\/p><\/div>\n<div style=\"margin: 32px 0 16px; font-size: 12px; text-align: center; border-top: 1px solid #e9edf2; padding-top: 16px; color: #5f7d9c;\">\n        Alle Spezifikationen vorbehaltlich der endg\u00fcltigen technischen Vereinbarung. Benlong Automation \u2013 IEC\/ANSI-konforme L\u00f6sungen f\u00fcr Alterungstests von Z\u00e4hlern zur Gew\u00e4hrleistung der Zuverl\u00e4ssigkeit intelligenter Stromnetze.\n    <\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Pr\u00fcfstand f\u00fcr die Alterungspr\u00fcfung von Drehstromz\u00e4hlern mit Pr\u00e4zisionsstromquelle ZN-D3000. Vertikales Rack mit hoher Dichte (bis zu 96 Positionen), Echtzeit-Z\u00e4hlerstands\u00fcberwachung, Kommunikationspr\u00fcfung (RS485\/optisch), automatischer Schutz, Datenerfassung. Reduziert die Ausfallrate in der Anfangsphase und gew\u00e4hrleistet eine Lebensdauer von 15 Jahren. IEC\/ANSI-konform.<\/p>","protected":false},"featured_media":66,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[20],"product_tag":[],"class_list":["post-67","product","type-product","status-publish","has-post-thumbnail","product_cat-test-bench-project","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/benlongkj.com\/de\/wp-json\/wp\/v2\/product\/67","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/benlongkj.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/benlongkj.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/de\/wp-json\/wp\/v2\/comments?post=67"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/de\/wp-json\/wp\/v2\/media\/66"}],"wp:attachment":[{"href":"https:\/\/benlongkj.com\/de\/wp-json\/wp\/v2\/media?parent=67"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/benlongkj.com\/de\/wp-json\/wp\/v2\/product_brand?post=67"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/benlongkj.com\/de\/wp-json\/wp\/v2\/product_cat?post=67"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/benlongkj.com\/de\/wp-json\/wp\/v2\/product_tag?post=67"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}