{"id":27,"date":"2026-06-01T10:37:36","date_gmt":"2026-06-01T10:37:36","guid":{"rendered":"https:\/\/khkrh7q1ur.wpdns.site\/product\/auxiliary-and-signal-contact-test-bench\/"},"modified":"2026-06-10T07:29:08","modified_gmt":"2026-06-10T07:29:08","slug":"auxiliary-and-signal-contact-test-bench-product","status":"publish","type":"product","link":"https:\/\/benlongkj.com\/de\/produkt\/auxiliary-and-signal-contact-test-bench-product\/","title":{"rendered":"Pr\u00fcfstand f\u00fcr Hilfs- und Signalkontakte"},"content":{"rendered":"<div class=\"bl-pdp-wrapper\">\n<div class=\"bl-pdp-split\">\n<div class=\"bl-pdp-split-text\">\n<div class=\"bl-pdp-badge\">Dual-Mode-Logik \u00b7 Kontaktwiderstand<\/div>\n<h1>Pr\u00fcfstand f\u00fcr Hilfs- und Signalkontakte f\u00fcr RCBO\/MCB<\/h1>\n<p>Die automatische und manuelle Pr\u00fcfung von Hilfskontakten und Alarmkontakten (bzw. Signalen) erfolgt auf dem Pr\u00fcfstand. Der Pr\u00fcfstand best\u00e4tigt, dass sich der Kontaktzustand bei jedem manuellen \u00d6ffnen oder Schlie\u00dfen des Leistungsschaltergriffs von \u201eNormal\u201c auf \u201eUmgekehrt\u201c (oder umgekehrt) \u00e4ndert (\u00dcberpr\u00fcfung des Zustands eines Hilfskontakts bei jedem manuellen \u00d6ffnen oder Schlie\u00dfen des Leistungsschaltergriffs durch eine Person). Der Pr\u00fcfstand best\u00e4tigt, dass sich der Kontaktzustand NICHT \u00e4ndert, w\u00e4hrend der Leistungsschalter manuell ge\u00f6ffnet wird (\u00dcberpr\u00fcfung des Zustands eines Alarmkontakts, w\u00e4hrend eine Person den Leistungsschalter manuell \u00f6ffnet), und dass er sich bei Auftreten eines Fehlers nicht \u00e4ndert, wohl aber seinen Zustand \u00e4ndert, wenn eine Fehlerausl\u00f6sung simuliert wird. (Die Simulation erfolgt entweder \u00fcber die RCBO-Testtaste oder durch Herbeif\u00fchren eines Kurzschlusses.) Der Pr\u00fcfstand misst au\u00dferdem den Widerstand des Hilfskontakts mit einem Mikroohmmeter und f\u00fchrt Hochspannungspr\u00fcfungen durch, um sicherzustellen, dass kein Ableitstrom auftritt. Der Pr\u00fcfstand eignet sich f\u00fcr Qualit\u00e4tskontrolllabore und Fertigungslinien sowie f\u00fcr die Eingangskontrolle von Hilfskontaktmodulen.<\/p>\n<p><span style=\"color: #2872fa; font-weight: 500;\">Standardlieferung: 30\u201345 Tage | Dual-Mode-Logikpr\u00fcfung | Kontaktwiderstand und Hochspannungspr\u00fcfung<\/span><\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-split-media\">\n            <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Auxiliary-and-Signal-Contact-test-bench.webp\" alt=\"Pr\u00fcfstand f\u00fcr Hilfs- und Signalkontakte\"><\/p>\n<div style=\"font-size: 11px; margin-top: 8px;\">Dual-Mode-Kontaktpr\u00fcfstation (tats\u00e4chliches Produkt)<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-definition\">\n<h2>Welche Probleme l\u00f6st dieser Pr\u00fcfstand?<\/h2>\n<p>Die Hilfs-\/Signalkontakte sind wesentliche Komponenten bei der Fern\u00fcberwachung von Leistungsschaltern. Es gibt jedoch drei Hauptprobleme, die sowohl Herstellern als auch Anwendern von Leistungsschaltern gemeinsam sind: eine fehlerhafte Schaltlogik (z. B. Ausl\u00f6sen eines Alarms bei manueller Ausl\u00f6sung, was zu Fehlalarmen f\u00fchrt); hoher Kontaktwiderstand (Oxidation der Kontakte f\u00fchrt zu einem Verlust der Signal\u00fcbertragung); und Isolationsdurchschlag (dies kann ein Sicherheitsrisiko darstellen). Der Pr\u00fcfstand behebt alle drei Probleme mithilfe einer getesteten Abfolge zur Validierung der Dual-Mode-Logik (Hilfs- vs. Alarm) sowie zur Messung des Kontaktwiderstands (zur Identifizierung defekter Leistungsschalter).<\/p>\n<div class=\"bl-pdp-feature-grid\">\n<div class=\"bl-pdp-feature-card\">\n                <strong>Dual-Mode-Logikverifikation<\/strong><\/p>\n<p>Testen Sie den Hilfsmodus (die Kontakte schalten bei Bet\u00e4tigung des Handgriffs) und den Alarmmodus (die Kontakte schalten nur bei einer Fehlerabschaltung, nicht jedoch bei einer manuellen \u00d6ffnung).<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Messung des Kontaktwiderstands<\/strong><\/p>\n<p>Misst den Widerstand geschlossener Kontakte (typischerweise &lt;50 m\u03a9) \u2013 erkennt Oxidation oder Kontaktfehler, die zu Signalausf\u00e4llen f\u00fchren k\u00f6nnen.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>Pr\u00fcfung der Durchschlagfestigkeit (Hi-Pot)<\/strong><\/p>\n<p>Legt gem\u00e4\u00df IEC 60947-5-1 eine Wechselspannung von 1500 V oder 2000 V zwischen den Klemmen an, um die Isolationsintegrit\u00e4t zu \u00fcberpr\u00fcfen.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-feature-card\">\n                <strong>\u00dcberpr\u00fcfung der mechanischen Verriegelung<\/strong><\/p>\n<p>\u00dcberpr\u00fcft den korrekten Sitz und die korrekte Bet\u00e4tigung des Hilfs-\/Signalkontakts bei Montage an einem RCBO\/MCB.<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery\">\n<h2>Testverfahren und Vorteile f\u00fcr den Kunden<\/h2>\n<div class=\"bl-pdp-gallery-grid\">\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Intelligence-Visibility.webp\" alt=\"Informationstransparenz \u2013 Echtzeit\u00fcberwachung\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Intelligenz und Transparenz \u2013 Echtzeitanzeige des Kontaktzustands (NO\/NC) und der Testparameter<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Efficiency-Sustainability.webp\" alt=\"Effizienz und Nachhaltigkeit \u2013 Energieeinsparung\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Effizienz und Nachhaltigkeit \u2013 automatisierte Testsequenz reduziert den Zeitaufwand f\u00fcr manuelle Tests um 80%<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Design-Integration.webp\" alt=\"Designintegration \u2013 modulare Konstruktion\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Konstruktion und Integration \u2013 Universalhalterung f\u00fcr verschiedene Hilfskontaktmodelle<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-gallery-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Safety-Reliability.webp\" alt=\"Sicherheit und Zuverl\u00e4ssigkeit \u2013 strenge Tests\"><\/p>\n<div class=\"bl-pdp-gallery-caption\">Sicherheit und Zuverl\u00e4ssigkeit \u2013 geschlossener Hochspannungspr\u00fcfbereich mit Verriegelung sch\u00fctzt den Bediener<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<h2>Technische Spezifikationen<\/h2>\n<div class=\"bl-pdp-summary\">Pr\u00fcfstand f\u00fcr Hilfs- und Alarmkontakte. Dual-Mode-Logik (Hilfs-\/Alarm), Kontaktwiderstand (&lt;50 m\u03a9), Hochspannungspr\u00fcfung (1500 V\/2000 V AC), \u00dcberpr\u00fcfung der mechanischen Verriegelung.<\/div>\n<div class=\"bl-pdp-table-wrap\">\n<table class=\"bl-pdp-table\">\n<tbody>\n<tr>\n<th style=\"width: 35%;\">Testfunktionen<\/th>\n<td>Logik f\u00fcr den Hilfsbetrieb, Logik f\u00fcr den Alarmbetrieb, Kontaktwiderstand, Durchschlagfestigkeit (Hi-Pot), mechanische Verriegelung\n                <\/td>\n<\/tr>\n<tr>\n<th>Messung des Kontaktwiderstands<\/th>\n<td>Messbereich 0\u2013200 m\u03a9, Genauigkeit \u00b11%, Pr\u00fcfstrom 1 A Gleichstrom (Mikroohmmeter)\n                <\/td>\n<\/tr>\n<tr>\n<th>Abnahme des Kontaktwiderstands<\/th>\n<td>&lt;50 m\u03a9 (typisch), programmierbarer Grenzwert\n                <\/td>\n<\/tr>\n<tr>\n<th>Hochspannungspr\u00fcfspannung<\/th>\n<td>1500 V AC \/ 2000 V AC (programmierbar, 1\u201360 Sekunden)\n                <\/td>\n<\/tr>\n<tr>\n<th>Schwellwert f\u00fcr den Leckstrom<\/th>\n<td>Programmierbar (z. B. 5 mA, 10 mA)\n                <\/td>\n<\/tr>\n<tr>\n<th>Test im Hilfsmodus<\/th>\n<td>Manuelle Bet\u00e4tigung (Schlie\u00dfen\/\u00d6ffnen) \u2013 automatische Durchgangspr\u00fcfung an NO-\/NC-Kontakten\n                <\/td>\n<\/tr>\n<tr>\n<th>Test des Alarmmodus \u2013 manuelles \u00d6ffnen<\/th>\n<td>Der Kontakt darf seinen Zustand NICHT \u00e4ndern\n                <\/td>\n<\/tr>\n<tr>\n<th>Test des Alarmmodus \u2013 Simulation einer Fehlerabschaltung<\/th>\n<td>Der Kontakt muss seinen Zustand sofort \u00e4ndern (NO \u2192 geschlossen, NC \u2192 offen)\n                <\/td>\n<\/tr>\n<tr>\n<th>Verfahren zur Simulation einer Fehlerabschaltung<\/th>\n<td>Bei RCBO: automatisches Dr\u00fccken der \u201cT\u201d-Taste; bei MCB: Einspeisung eines Kurzschlussstroms (optional)\n                <\/td>\n<\/tr>\n<tr>\n<th>Stromversorgung<\/th>\n<td>220 V \u00b110% 50 Hz\n                <\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<h2>Wesentliche Vorteile f\u00fcr Kunden \u2013 Warum Hersteller diese Werkbank nutzen<\/h2>\n<div class=\"bl-pdp-grid\">\n<div class=\"bl-pdp-card\">\n<h4>Vorteil 1: Verhindert Fehlalarme im Au\u00dfendienst<\/h4>\n<p>Alarmkontakte werden nur dann auf ihre ordnungsgem\u00e4\u00dfe Funktion gepr\u00fcft (d.\u202fh. als Alarmkontakte), wenn ein tats\u00e4chlicher Fehler auftritt (z.\u202fB. durch Dr\u00fccken der RCBO-Pr\u00fcftaste oder durch Simulation eines Kurzschlusses). Sie werden zudem korrekt gepr\u00fcft, wenn der Schutzschalter manuell ausgel\u00f6st wird, ohne dass dabei ein Fehlalarm ausgel\u00f6st wird. Dies tr\u00e4gt dazu bei, die Verschwendung von Ressourcen zu vermeiden, die f\u00fcr die Behebung von Fehlalarmen erforderlich sind, welche bei den Kunden Unsicherheit hinsichtlich der Zuverl\u00e4ssigkeit ihrer Anlagen hervorrufen.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Vorteil 2: Erkennt Kontaktkorrosion, bevor sie zu einem Ausfall f\u00fchrt<\/h4>\n<p>R\u00fccksendungen und Serviceeins\u00e4tze sind f\u00fcr Hersteller kostspielig; hohe Kontaktwiderst\u00e4nde (50 m\u03a9) f\u00fchren zu Signalunterbrechungen oder -ausf\u00e4llen. Die Hersteller erfassen dieses intermittierende Signal und f\u00fchren Reparaturen an den Ger\u00e4ten durch, bevor diese an ein Servicecenter zur\u00fcckgeschickt werden.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Vorteil 3: Gew\u00e4hrleistet die Unversehrtheit der Isolierung und sorgt so f\u00fcr Sicherheit<\/h4>\n<p>Eine Durchschlagfestigkeitspr\u00fcfung wird durchgef\u00fchrt, indem die vorgeschriebene Hochspannung (1500 V oder 2000 V) an die Anschl\u00fcsse angelegt und auf Isolationsfehler sowie auf Leckstrom gepr\u00fcft wird. Daher ist eine Durchschlagfestigkeitspr\u00fcfung besonders wichtig f\u00fcr Ger\u00e4te mit Hilfskontakten, die an Niederspannungs-SPSen oder Steuerkreise angeschlossen sind, da ein Versagen des Isoliermaterials zu Sch\u00e4den an sehr teuren Automatisierungsger\u00e4ten oder zu einer Stromschlaggefahr f\u00fchren k\u00f6nnte.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-card\">\n<h4>Vorteil 4: Schnelle, wiederholbare Tests<\/h4>\n<p>Durch die Automatisierung der Dual-Mode-Logik-Testsequenz k\u00f6nnen die Validierung und Pr\u00fcfung eines Hilfskontaktmoduls im Labortest nun in weniger als 30 Sekunden abgeschlossen werden \u2013 im Vergleich zu mehreren Minuten bei manuellen Multimeter-Tests. Ein einzelner Bediener kann w\u00e4hrend einer Schicht Hunderte dieser Module pr\u00fcfen, wobei die wiederholbaren Ergebnisse der Genauigkeit nach 100% entsprechen.<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-partners\">\n        <span class=\"bl-pdp-partners-title\">Von Branchenf\u00fchrern gesch\u00e4tzt<\/span><\/p>\n<div class=\"bl-pdp-partners-list\">\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738413289.webp\" alt=\"ABB\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594739263598.webp\" alt=\"DELIXI\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594739675877.webp\" alt=\"EKF\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594741141751.webp\" alt=\"KRIPAL\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738593989.webp\" alt=\"HPL\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738101609.webp\" alt=\"CHAC\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738124777.webp\" alt=\"Schneider\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738797907.webp\" alt=\"IEK-GRUPPE\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738812289.webp\" alt=\"SUNIR\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738411369.webp\" alt=\"Bevone\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738389707.webp\" alt=\"Weg\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738361034.webp\" alt=\"HUYU\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738416677.webp\" alt=\"RAAD\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738314557.webp\" alt=\"WALTONE\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738445639.webp\" alt=\"Havells\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<div class=\"bl-pdp-partner-item\">\n                <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/1780594738720809.webp\" alt=\"C&amp;S Electric\" style=\"width: 100%; height: auto; aspect-ratio: 2 \/ 1; object-fit: contain;\">\n            <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-case\">\n<h3>Kundenerfolg \u2013 Vermeidung von R\u00fccksendungen aufgrund von Fehlalarmen<\/h3>\n<p>Bei einem etablierten RCBO-Hersteller wiesen 5% der aus dem Feld zur\u00fcckgesandten Ger\u00e4te Probleme mit den Hilfskontaktmodulen auf, die bei manuellem \u00d6ffnen des Systems Fehlalarme ausl\u00f6sten. Das Unternehmen untersuchte die Ursache dieser Probleme und stellte fest, dass die Ursache in uneinheitlichen Logiktests w\u00e4hrend der Produktion lag. Daraufhin f\u00fchrte es einen Pr\u00fcfstand f\u00fcr Hilfs- und Signalkontakte mit automatisierten Dual-Mode-Tests zur Logik\u00fcberpr\u00fcfung ein und erzielte folgende Ergebnisse:<\/p>\n<div class=\"bl-pdp-case-stats\">\n<div class=\"bl-pdp-case-stat\"><strong>0.1%<\/strong> Erneut Fehlalarm (R\u00fcckgang gegen\u00fcber 5%)<\/div>\n<div class=\"bl-pdp-case-stat\"><strong>100%<\/strong> Testabdeckung f\u00fcr Logik und Kontaktwiderstand<\/div>\n<div class=\"bl-pdp-case-stat\"><strong>$200k\/Jahr<\/strong> Einsparungen bei Garantie- und Au\u00dfendienstkosten<\/div>\n<\/p><\/div>\n<p style=\"margin-top: 12px; font-size: 14px;\">Die Pr\u00fcfbank hat sich bereits innerhalb von vier Monaten nach dem Kauf amortisiert und dient zudem als erstklassige Pr\u00fcfstation f\u00fcr jeden hergestellten Hilfskontakt.<\/p>\n<\/p><\/div>\n<h2>Anwendungsbereiche \u2013 Wo diese Werkbank den gr\u00f6\u00dften Mehrwert bietet<\/h2>\n<div class=\"bl-pdp-feature\">\n<div class=\"bl-pdp-feature-list\">\n<div class=\"bl-pdp-feature-item\"><strong>Herstellung von Hilfskontakten<\/strong> \u2013 Abschlie\u00dfende Qualit\u00e4tskontrolle der Kontaktlogik, des Widerstands und der Isolation<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Montagelinien f\u00fcr RCBO\/MCB<\/strong> \u2013 Inline-Pr\u00fcfung der montierten Hilfs- und Signalkontakte<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>Wareneingangspr\u00fcfung<\/strong> \u2013 Pr\u00fcfung der von Lieferanten bezogenen Hilfskontaktmodule<\/div>\n<div class=\"bl-pdp-feature-item\"><strong>F&amp;E-Validierung<\/strong> \u2013 Charakterisierung neuer Hilfs-Kontaktdesigns<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<h2>Kundenspezifische Entwicklung &amp; Lieferung<\/h2>\n<div class=\"bl-pdp-steps\">\n<div class=\"bl-pdp-step\"><strong>1. Analyse von Kontaktproben<\/strong> 7\u201315 Tage \u00b7 Hilfs-\/Signalkontaktmodul, RCBO\/MCB zum Einbau<\/div>\n<div class=\"bl-pdp-step\"><strong>2. Fixture- und Logikprogrammierung<\/strong> 10\u201320 Tage \u00b7 Universalhalterung, Dual-Mode-Testablauf<\/div>\n<div class=\"bl-pdp-step\"><strong>3. Fertigung und Montage<\/strong> 30-45 Tage<\/div>\n<div class=\"bl-pdp-step\"><strong>4. Pre-FAT<\/strong> Im Werk Benlong<\/div>\n<div class=\"bl-pdp-step\"><strong>5. Installation und Schulung<\/strong> Vor Ort 2\u20133 Tage<\/div>\n<div class=\"bl-pdp-step\"><strong>6. Abschlie\u00dfender SAT<\/strong> 2\u20133 Tage \u00b7 Abnahmeprotokoll<\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-cta\">\n<h2>Angebot f\u00fcr einen ma\u00dfgeschneiderten Pr\u00fcfstand f\u00fcr Hilfskontakte anfordern<\/h2>\n<p>Bitte stellen Sie uns die Pr\u00fcfspezifikationen und Muster f\u00fcr Hilfs- bzw. Signalkontakte zur Verf\u00fcgung. Wir werden einen Pr\u00fcfstand entwickeln, der sowohl Dual-Mode-Pr\u00fcfungen als auch Kontaktwiderstandsmessungen (Low-Level) sowie Hochspannungspr\u00fcfungen erm\u00f6glicht, und eine Rentabilit\u00e4tsanalyse (ROI) erstellen.<\/p>\n<p>        <a class=\"bl-pdp-btn\" href=\"\/de\/contact\/\">Jetzt anfragen<\/a><\/p>\n<p class=\"bl-pdp-footnote\">WhatsApp: +86 150 5837 0007 | E-Mail: xsb@benlongkj.cn | Support in Englisch und Chinesisch<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-two-col\">\n<div class=\"bl-pdp-col-main\">\n<h3>Warum sollten Sie sich bei Kontaktpr\u00fcfst\u00e4nden f\u00fcr Benlong entscheiden?<\/h3>\n<ul>\n<li>Mehr als 15 Jahre Erfahrung im Designbereich <strong>Pr\u00fcfger\u00e4te f\u00fcr Kontaktmessungen<\/strong> f\u00fcr elektrische Niederspannungskomponenten<\/li>\n<li>Bew\u00e4hrte Dual-Mode-Logikpr\u00fcfung (Hilfs- vs. Alarmmodus) \u2013 verhindert Fehlalarme<\/li>\n<li>Integrierte Kontaktwiderstandsmessung (Genauigkeit: \u00b11%) und Hochspannungspr\u00fcfung<\/li>\n<li>Universelle Halterung f\u00fcr verschiedene Modelle von Hilfskontakten<\/li>\n<li>Weltweiter Service und Ersatzteilsupport<\/li>\n<\/ul><\/div>\n<div class=\"bl-pdp-col-side\">\n<h3>Im Lieferumfang der Standard-Werkbank enthalten<\/h3>\n<p>Universelles Ger\u00e4t f\u00fcr Hilfssignalkontakte mit automatischer Griffbet\u00e4tigung im Hilfsmodus, St\u00f6rungsausl\u00f6sesimulator und\/oder Testknopfbet\u00e4tiger zur Kurzschlusseinleitung. Mikroohmmeter zur Messung des Kontaktwiderstands. Hochspannungs-Wechselstrompr\u00fcfger\u00e4t f\u00fcr 2000 V. SPS mit HMI. OK\/NG-Anzeigeleuchten. Sicherheitsgeh\u00e4use. Bedienungsanleitungen. Kalibrierzertifikate. 1 Jahr Garantie.<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"bl-pdp-internal-links\">\n        <span class=\"bl-pdp-internal-links-title\">Verwandte L\u00f6sungen<\/span><\/p>\n<div class=\"bl-pdp-links-list\">\n            <a href=\"https:\/\/benlongkj.com\/de\/rcbo-semi-automatic-comprehensive-test-bench-product\/\">Halbautomatischer RCBO-Vollteststand<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/de\/mcb-automatic-testing-line\/\">MCB-Automatische Pr\u00fcflinie<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/de\/ac-contactor-comprehensive-test-machine-product\/\">Umfassende Pr\u00fcfmaschine f\u00fcr Wechselstromsch\u00fctze<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/de\/mccb-semi-automatic-high-voltage-test-bench-product\/\">MCCB Halbautomatischer Hochspannungspr\u00fcfstand<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/de\/load-isolation-switch-automatic-testing-line-product\/\">Pr\u00fcfleitung f\u00fcr Lasttrennschalter<\/a><br \/>\n            <a href=\"https:\/\/benlongkj.com\/de\/mcb-handle-link-automatic-assembly-machine-product\/\">MCB-Griffverbindungs-Montagemaschine<\/a>\n        <\/div>\n<\/p><\/div>\n<h2>H\u00e4ufig gestellte Fragen<\/h2>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Was ist der Unterschied zwischen dem Hilfsmodus und dem Alarmmodus?<\/div>\n<p>Die Kontakte f\u00fcr den Hilfsbetrieb \u00e4ndern ihren Zustand bei jeder Bet\u00e4tigung des Leistungsschaltergriffs, unabh\u00e4ngig davon, ob es sich um eine manuelle Bet\u00e4tigung (wie das \u00d6ffnen oder Schlie\u00dfen) oder um eine Fernanzeige der Position handelt; sie \u00e4ndern ihren Zustand nicht aufgrund eines Ausl\u00f6seereignisses (Fehler), wie beispielsweise einer \u00dcberlast oder eines Kurzschlusses. Die im Alarmmodus verwendeten Kontakte zeigen den Zustand des Leistungsschalters nach einer durch einen Fehler verursachten Ausl\u00f6sung an. Der Zweck der Pr\u00fcfung des Pr\u00fcfstands in beiden Modi besteht darin, die erwartete Funktion der Kontakte zu \u00fcberpr\u00fcfen.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Wie simuliert der Pr\u00fcfstand eine Fehlerabschaltung f\u00fcr Tests im Alarmmodus?<\/div>\n<p>Bei RCBOs muss kein Pr\u00fcfkreis aufgebaut werden, da das Pr\u00fcfger\u00e4t durch Dr\u00fccken der T-Taste (Test) auf der Abdeckung des Schutzschalters automatisch eine Pr\u00fcfung durchf\u00fchrt. Bei MCBs kann das Pr\u00fcfger\u00e4t einen einstellbaren Kurzschlussstrom einspeisen, um die f\u00fcr die Ausl\u00f6sung des magnetischen Ausl\u00f6semechanismus erforderlichen Bedingungen zu schaffen, oder die Verwendung eines mechanischen Ausl\u00f6sers zur Ausl\u00f6sung des Mechanismus erfordert ebenfalls die Einrichtung eines Pr\u00fcfkreises. Die \u00c4nderung des Kontaktzustands wird in Echtzeit \u00fcberpr\u00fcft.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Wie hoch darf der Kontaktwiderstand bei Hilfskontakten sein?<\/div>\n<p>Die Norm IEC 60947-5-1 empfiehlt f\u00fcr neue Kontakte einen Wert von &lt;50 m\u03a9. An dem Pr\u00fcfstand k\u00f6nnen Sie einen programmierbaren Grenzwert (z. B. 50 m\u03a9) festlegen. Ein h\u00f6herer Widerstand deutet auf Oxidation, Verschmutzung oder unzureichenden Anpressdruck hin, was zu einer unterbrochenen Signal\u00fcbertragung f\u00fchren kann.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Unterst\u00fctzt das Pr\u00fcfger\u00e4t verschiedene Kontaktstiftkonfigurationen (z. B. 11-12-14)?<\/div>\n<p>Ja. An der Universalhalterung befinden sich Messspitzen, die an verschiedene Pin-Konfigurationen angepasst werden k\u00f6nnen. Sobald das Produktrezept ausgew\u00e4hlt ist, ermittelt die Testsequenz die Pin-Konfiguration f\u00fcr Sie.<\/p>\n<\/p><\/div>\n<div class=\"bl-pdp-faq-item\">\n<div class=\"bl-pdp-faq-question\">Kann das Pr\u00fcfger\u00e4t sowohl normalerweise offene als auch normalerweise geschlossene Kontakte gleichzeitig pr\u00fcfen?<\/div>\n<p>Das Pr\u00fcfger\u00e4t testet den Durchgang der NO- und NC-Kontakte w\u00e4hrend des gesamten Pr\u00fcfablaufs. Bei der Hilfspr\u00fcfung sollte der Durchgang \u00fcber den NO-Kontakt bestehen, solange sich der Leistungsschalter in der EIN-Stellung befindet, und \u00fcber den NC-Kontakt, solange sich der Leistungsschalter in der AUS-Stellung befindet. Im Alarmmodus wird gepr\u00fcft, ob bei einer Fehlerausl\u00f6sung nur der entsprechende Kontakt seinen Zustand \u00e4ndert.<\/p>\n<\/p><\/div>\n<div style=\"margin: 32px 0 16px; font-size: 12px; text-align: center; border-top: 1px solid #e9edf2; padding-top: 16px; color: #5f7d9c;\">\n        Alle Angaben vorbehaltlich der endg\u00fcltigen technischen Vereinbarung. Benlong Automation \u2013 Testl\u00f6sungen f\u00fcr Hilfs- und Signalkontakte f\u00fcr Hersteller von RCBO- und MCB-Schaltern.\n    <\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Pr\u00fcfstand f\u00fcr Hilfs- und Signalkontakte von RCBO\/MCB. Pr\u00fcft die Dual-Mode-Logik (Hilfs- und Alarmkontakt) sowie den Kontaktwiderstand (&lt;50 m\u03a9) und Durchschlagfestigkeit (1500 V\/2000 V). Verhindert Fehlalarme, erkennt Oxidation und gew\u00e4hrleistet die Isolationsintegrit\u00e4t. Ideal f\u00fcr Qualit\u00e4tskontrolllabore und Fertigungslinien. Entspricht der Norm IEC 60947-5-1.\n<\/p>","protected":false},"featured_media":26,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[20],"product_tag":[],"class_list":["post-27","product","type-product","status-publish","has-post-thumbnail","product_cat-test-bench-project","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/benlongkj.com\/de\/wp-json\/wp\/v2\/product\/27","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/benlongkj.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/benlongkj.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/de\/wp-json\/wp\/v2\/comments?post=27"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/benlongkj.com\/de\/wp-json\/wp\/v2\/media\/26"}],"wp:attachment":[{"href":"https:\/\/benlongkj.com\/de\/wp-json\/wp\/v2\/media?parent=27"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/benlongkj.com\/de\/wp-json\/wp\/v2\/product_brand?post=27"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/benlongkj.com\/de\/wp-json\/wp\/v2\/product_cat?post=27"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/benlongkj.com\/de\/wp-json\/wp\/v2\/product_tag?post=27"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}